GSD8 Software Parameters
Parameter
Description
Value Range
Units
Default
Parameter Used by:
GSD8-
240-5C
All other
GSD8
drives
0
Select parameter 0 to return to
Run mode
n/a
–
n/a
Read-Only Parameters
1
Model Number
10 = GSD8-240-5C, 45 = GSD8-
240-5C-P, 10C-P, 10N4X, 10N4X-A,
10N4X-U
10
45
2
Software Build
1-9999
n/a
3
Hardware Version
1-9999
n/a
4
Serial Number - Major (Reserved) N/A
n/a
Software Version (Mark Reserved) 1-9999
n/a
5
Serial Number - Minor (Reserved) N/A
n/a
Serial Number - Major (Reserved) 0-9999
n/a
6
Serial Number - Minor (Reserved) 0-9999
n/a
8
Drive Condition Flags
(See "Flags" - Table #1 Below)
Decimal
n/a
9
Drive Condition Flags
(See "Flags" - Table #2 Below)
Decimal
n/a
General Setup Parameters
10
Operating Mode*
1 = Rate Mode
2 = Time Mode
3 = Follower Mode (see also
parameter 35)
1
*Power must be removed and re-applied to the GSD8 for a change in Operating Mode to take effect
11
Display Intensity
Display Brightness
0-31 - (Dim-Bright)
20
26
12
Display Mode
1 = Target Speed
2 = S1 Actual Speed
3 = S2 (Leader) Speed
1
13
Decimal Point Position
0 = Disabled - (XXXX)
1 = X.XXX
2 = XX.XX
3 = XXX.X
4 = XXXX
0
14
Keypad Mode
1 = Linear - Constant Rate
2 = Non-Linear - Accelerating Rate
2
15
Keypad Scroll Delay
0-30 - (Fast-Slow)
10
16
Power-Up Target Speed
1 = Force Zero Speed
2 = Force Power-up Value
3 = Use Previous Target Speed
3
S1 / S2 Input Edge & Prescaler
Configuration
0 = S1 Rising / 1 - S2 Rising / 1
1 = S1 Falling / 1 - S2 Rising / 1
2 = S1 Falling / 4 - S2 Rising / 1
3 = S1 Falling / 16 - S2 Rising / 1
4 = S1 Rising / 1 - S2 Falling / 1
5 = S1 Falling / 1 - S2 Falling / 1
6 = S1 Falling / 4 - S2 Falling / 1
7 = S1 Falling / 16 - S2 Falling / 1
8 = S1 Rising / 1 - S2 Falling / 4
9 = S1 Falling / 1 - S2 Falling / 4
10 = S1 Falling / 4 - S2 Falling / 4
11 = S1 Falling / 16 - S2 Falling / 4
12 = S1 Rising / 1 - S2 Falling / 16
13 = S1 Falling / 1 - S2 Falling / 16
14 = S1 Falling / 4 - S2 Falling / 16
15 = S1 Falling / 16 - S2 Falling / 16
0
17
Power-Up Value
0-9999
(Eng.
units)
0