Automationdirect.com Productivity 2000 P2-32ND3-1 Скачать руководство пользователя страница 1

 

Sales 800-633-0405 

www.productivity2000.com 

1

Input Specifications

Inputs per Module 

32 (Sink/Source)

Operating  Voltage  Range  (Tolerance)                  12–24 VDC

Input Voltage Range

10.2–26.4 VDC

Peak Voltage Range 

30VDC

Input Current

3.5 mA @ 12VDC

7.5 mA @ 24VDC

Maximum Input Current

10mA @ 26.4 VDC

ON Voltage Level

>9.5 VDC

OFF Voltage Level 

<7 VDC

Minimum ON Current

2mA

Maximum OFF Current 

1.6 mA

OFF to ON Response

2ms Maximum, 1ms Typical

ON to OFF Response

2ms Maximum, 1ms Typical

Status Indicators

Logic Side (32 Points)

Commons per Module

4 Isolated (8 points/common) 

D3-1

12–

Warranty: Thirty-day money-back guarantee. Two-year limited replacement. 

(See www.productivity2000.com for details).

Terminal Block sold separately, 

(see wiring options on page 3).

Input Specifications .................................................. 1

Module Installation Procedure .................................. 2

QR Code .................................................................. 2 

Hot Swap Information ............................................... 3

Wiring Options .......................................................... 3

Wiring Diagram and Schematic ................................ 3

Warning .................................................................... 4

Connector Specifications .......................................... 4

General Specifications ............................................. 4

P2-32ND3-1 DC Input

The P2-32ND3-1 DC Input Module provides 

thirty-two 12–24 VDC sink/source inputs for 

use with the Productivity2000 System.

®

Содержание Productivity 2000 P2-32ND3-1

Страница 1: ...esponse 2ms Maximum 1ms Typical Status Indicators Logic Side 32 Points Commons per Module 4 Isolated 8 points common D3 1 12 Warranty Thirty day money back guarantee Two year limited replacement See www productivity2000 com for details Terminal Block sold separately see wiring options on page 3 Input Specifications 1 Module Installation Procedure 2 QR Code 2 Hot Swap Information 3 Wiring Options 3...

Страница 2: ... reader application to display the module s product insert Module Installation WARNING Do not apply field power until the following steps are completed See hot swapping procedure for exceptions Step One Align module catch with base slot and rotate module into connector Step Two Pull top locking tab toward module face Click indicates lock is engaged Step Three Attach field wiring using the removabl...

Страница 3: ...ZL CBL40 2 ZIPLink Pig Tail Cables 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZL P3 CBL40 1P ZL P3 CBL40 2P 3 Accessories ZL RTB COM TW SD SL 1 TW SD MSL 1 1 Cable ZIPLink Module Complete System 2 ZL RTB COM provides a common connection point for power or ground ZL RTB 40 1 ZL RTB40 ZL LTB32 24 1 TB5 TB6 TB7 TB8 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 D15 D16 D17 D18 D19 D20 D21 D22 D23 D24 D25 ...

Страница 4: ...time it was printed At AutomationDirect com we constantly strive to improve our products and services so we reserve the right to make changes to the products and or publications at any time without notice and without any obligation This publication may also discuss features that may not be available in certain revisions of the product General Specifications Operating Temperature 0 to 60 C 32 to 14...

Отзывы: