![Automation Direct Stellar SR55 Series Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/automation-direct/stellar-sr55-series/stellar-sr55-series_user-manual_3021753036.webp)
Page 3–6
Stellar
®
SR55 Series Soft Starter User Manual – 1st Ed, Rev F – 09/18/2019
Chapter 3: Configuration and Parameters
p
ARAmeTeR
s
ummARy
s
ummary
of
p
arameTers
n
oT
C
onfigurable
T
hrough
T
ouChsCreen
m
enu
These parameters are configurable through network communications.
Summary – Parameters Not Configurable Through Touchscreen
Group
Parameter
Units Range
Read /
Write
Modbus
Default
Setting
User
Setting
Address Hex
Control Commands
(for Digital Inputs)
[detailed info starts
P0�0 – Start/Stop
toggle
OFF (Stop) / ON (Start)
R/W
17920
4600
OFF
P0�1 – Freeze Ramp
toggle
OFF / ON
R/W
18240
4740
OFF
P0�2 – Reset
toggle
OFF / ON
R/W
18368
47C0
OFF
P0�3 – External Trip
toggle
OFF / ON
R/W
18880
49C0
OFF
Status Indications
[detailed info starts
P0�4 – Ready
–
OFF / ON
Read
37184
9140
OFF
–
P0�5 – Enabled
–
OFF / ON
Read
37248
9180
OFF
–
P0�6 – Error
–
OFF / ON
Read
37312
91C0
OFF
–
P0�7 – Running
–
OFF / ON
Read
37632
9300
OFF
–
P0�8 – End Of Start
–
OFF / ON
Read
37760
9380
OFF
–
P0�9 – Current Limit
–
OFF / ON
Read
37824
93C0
OFF
–
P0�10 – iERS Active
–
OFF / ON
Read
38080
94C0
OFF
–
P0�12 – I/O Status Register
–
0 to 255
Read
62016
F240
OFF
–
Block Transfer
[detailed info starts
P0�20~P0�35 –
Block Transfer Address Pointers
–
0 to 65535
R/W
17600
~17615
44C0
~44CF
OFF
P0�40~P0�55 –
Block Transfer Data Locations
–
0 to 4,294,967,295
R/W
17664
~17694
4500
~451E
OFF
s
ummary
of
p
arameTers
for
a
uTo
s
eTup
Summary – Parameters for Touchscreen Setup – “Auto Setup” Category
Aut
o Setup
Group
Parameter
Units Range
Read /
Write
Modbus
Default
Setting
User
Setting
Address Hex
Auto
Setup
[detailed
info starts
]
P0�11 – Application
n/a
See the previous “Auto Setup
Parameter Settings” table (
R/W
19200
4B00 Default
P5�1 –
Trip Class (Automatically
selected from Application
selection)
n/a
10, 20, 30
R/W
25664
6440 10
P5�0 – Motor Current
A
10% to 100% of SR55 rated current
R/W
25728
6480 100%
P7�0 – Control Method
n/a
Local Touch Screen
User Programmable
Two Wire Control
Three Wire Control
Modbus Network
R/W
59392
E800
Local
Touch
Screen
P10�0 –
Digital Input Voltage
V
230VAC, 110VAC, 24VDC
R/W
10880
2A80 230VAC
Содержание Stellar SR55 Series
Страница 1: ...Stellar SR55 Soft Starter User Manual SR55_UMW First Edition Revision F...
Страница 2: ...Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 BLANK PAGE...
Страница 6: ...Page W 4 Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 BLANK PAGE...
Страница 8: ...Page H 2 Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 BLANK PAGE...
Страница 14: ...TOC 6 Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 Table of Contents BLANK PAGE...
Страница 148: ...Page 5 22 Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 Chapter 5 Communications BLANK PAGE...
Страница 166: ...Page 6 18 Stellar SR55 Series Soft Starter User Manual 1st Ed Rev F 09 18 2019 Chapter 6 Accessories BLANK PAGE...