Questions and Answers about DL05 Micro PLCs

Q. What is the instruction set like?

A

.  The instruction set is very close to our popular DL240 CPU. However, there are significant 

additions, such as the drum instruction, networking, PID control and High-Speed I/O 

capabilities.

Q.  Do I have to buy the full 

Direct

SOFT programming package to program the 

DL05?

A

.   No, 

Direct

SOFT programming software is available for programming 

Direct

LOGIC PLCs 

for no additional charge; however this FREE version will only allow 100 maximum words 

to be programmed. Go to 

AutomationDirect.com

 for more information.

Q. Is the DL05 expandable?

A.

  No, the DL05 series are stand-alone PLCs with one slot for the installation of an available 

option module. They do not have expansion bases, such as our DL205 system which has 

expansion bases, yet are very compact and affordable.

Q. Does the DL05 have motion control capability?

A.

  Yes. The units with DC I/O have selectable high-speed input features on three inputs. There 

is also an optional High-Speed Counter I/O module available with special utility software. 

Either can accept pulse-type input signals for high-speed counting or timing applications and 

provide high-speed pulse-type output signals for stepper/servo motor control, monitoring, 

alarm or other discrete control functions. Three types of motion profiles are available, which 

are explained in Chapter 3.

Q. Are the ladder programs stored in a removable EEPROM?

A.

  The DL05 contains a non-removable FLASH memory for program storage, which may be 

written and erased thousands of times. You may transfer programs to/from the DL05 using 

Direct

SOFT on a PC, or the HPP (which does support a removable EEPROM). There is an 

optional CMOS RAM memory cartridge (MC) available (See Chapter 10).

Q. Does the DL05 contain fuses for its outputs?

A.

  There are no output circuit fuses. Therefore, we recommend fusing each channel, or fusing 

each common. See Chapter 2 for I/O wiring guidelines.

Q. Is the DL05 Micro PLC UL approved?

A.

  The Micro PLC has met the requirements of UL (Underwriters’ Laboratories, Inc.), and 

CUL (Canadian Underwriters’ Laboratories, Inc.).

Q. Does the DL05 Micro PLC comply with European Union (EU) Directives?

A.

 The Micro PLC has met the requirements of the European Union Directives (CE).

Содержание D0-05AA

Страница 1: ...is Chapter Introduction 1 2 Conventions Used 1 3 DL05 Micro PLC Components 1 4 I O Selection Quick Chart 1 5 Quick Start for PLC Checkout and Programming 1 6 Steps to Designing a Successful System 1 1...

Страница 2: ...surprised with how much you can accomplish with AutomationDirect products Supplemental Manuals The D0 OPTIONS M manual will be most helpful to select and use any of the optional modules that are avai...

Страница 3: ...to its immediate right will be a special note Notes represent information that may make your work quicker or more efficient The word NOTE in boldface will mark the beginning of the text When you see t...

Страница 4: ...tput points All DL05 Micro PLCs offer a large amount of program memory a substantial instruction set and advanced diagnostics Details of these features and more are covered in Chapter 3 CPU Specificat...

Страница 5: ...Input Output circuits which can interface to a wide variety of field devices In several instances a particular Input or Output circuit can interface to either DC or AC voltages or both sinking and so...

Страница 6: ...he DL05 Equipment Unpack the DL05 and gather the parts necessary to build this demonstration system The recommended components are DL05 Micro PLC AC power cord or DC power supply Toggle switches or si...

Страница 7: ...ly Be sure to follow the instructions in the accompanying WARNING note D0 O5DR D0 05DD D0 05DA D0 05DR D D0 05DD D DC input versions 12 24VDC 12 24VDC Power Supply Toggle Switches UL Listed User provi...

Страница 8: ...ctor covers Do not apply power at this time Step 4 Connect the Programming Device Most programmers will use DirectSOFT programming software installed on a personal computer Or you may need the portabi...

Страница 9: ...the DL05 PLC change CPU modes to Run or Program and enter a program If you are learning how to program with the Handheld Programmer make sure the CPU is in Program Mode the RUN LED on the front of th...

Страница 10: ...enter a program it is very helpful to understand how the DL05 system processes information This involves not only program execution steps but also involves the various modes of operation and memory la...

Страница 11: ...ur process After reviewing the programming concepts above you ll be equipped with a variety of tools to write your application program PWR RUN CPU TX1 RX1 TX2 RX2 TMR T1 K30 CNT CT3 K10 Standard RLL P...

Страница 12: ...also an optional High Speed Counter I O module available with special utility software Either can accept pulse type input signals for high speed counting or timing applications and provide high speed...

Страница 13: ...personal computer D2 HPP handheld programmer Other devices which communicate via K sequence protocol should work with the DL05 Micro PLC Contact the vendor for details A Port 2 The port is RS232 with...

Отзывы: