30
GDO-10V2L2 Toro
™
Owner Installation Instructions
Menu 6.3 First (SB1) Safety Beam Response Mode
The Safety Beams input can be confi gured to respond in one of three modes.
Reverses Close Cycles
In this mode, the Safety Beam input has no effect when opening but will cause the door to reverse if
activated when closing.
Close Cycles Stop
In this mode, the Safety Beam input has no effect when opening but will stop the door when closing.
Open and Close Cycles Stop
In this mode, all cycles are prevented from being completed or initiated when the Safety Beam input is
active.
Menu 6.4 Second Safety Beam (SB2) Response Mode
Same as above menu 6.3
Menu 6.5 Third Safety Beam (SB3) Response Mode
The third Safety Beam input can be confi gured to respond in one of four modes.
Reverses Close Cycles
In this mode, the Safety Beam input has no effect when opening but will cause the door to reverse if
activated when closing.
Close Cycles Stop
In this mode, the Safety Beam input has no effect when opening but will stop the door when closing.
Open and Close Cycles Stop
In this mode, all cycles are prevented from being completed or initiated when the Safety Beam input is
active.
Exit With SB1
Exiting through SB3 (third Safety Beam) and then SB1 (First Safety Beam) will activate the SB trigger auto
close.
Menu 6.6 Safety Beam Obstruction Reverse Time Mode
Normally after a Safety Beam obstruction the door will fully open to its open position. After a Safety Beam Close
obstruction, the doors open cycle can be reduced from 5 sec to its full open position.
Menu 6.7 GPI Input
GPI input can be confi gured as OSC, PED or DST setup. The GPI input terminal is activated by the N/O switch.
When GPI Selected As OSC:
If the door is moving, the activation of the GPI input or by a transmitter button with the OSC function assigned
will cause the door to stop. The next trigger will move the door in the opposite direction to the last travelled.
When GPI Input Is Confi gured As PED:
The activation of the GPI input or by a transmitter button with PED function assigned will open the door partially
to allow pedestrian access but prevent vehicle access. The position the door is driven to is automatically set to
halfway during setting of the travel limits, but can be adjusted to suit.
When GPI Input Is Confi gured As SWP:
Activation of GPI input in this mode will open the door.
When GPI Input Is Confi gured As MANUAL OPERATION:
Activation of GPI input in this mode will disable all the transmitters.
When GPI Input Is Confi gured As DST:
The GPI input can be used to switch between STD time and DST (daylight savings time). The time selected is the
amount of time added to STD time when DST is selected. The Options are OFF, 30, 60, 90 or 120 minutes. The
Control Board Adjustments