Safety Rules 

 

   

 

 

 

 

05

System Specifications 

 

   

 

 

 

 

06

Default Settings and Technical Specification     

 

 

 

  

06

About Your Operator 

 

   

 

 

 

 

07

Operating Controls 

 

   

 

 

 

 

08

Kit Contents  

 

   

 

 

 

 

10

Installation  

 

   

 

 

 

 

  

   Knockdown C-Rail  Assembly  

 

   

 

 

 

 

12

     C-Rail  Assembly  

 

   

 

 

 

 

13

     Mounting Operator for Track Type Door  

   

 

 

 

 

14

     Mounting Door Bracket & Arms 

 

   

 

 

 

 

15

     Safety Beam Installation 

 

   

 

 

 

 

15

Setting Speed and Limits  

 

   

 

 

 

 

     

Setting Speed Mode 

 

   

 

 

 

 

17

     Setting Limits Position 

 

   

 

 

 

 

18

Testing Safety Obstruction Force

 

 

   

 

 

 

  

19

Setting Safety Obstruction Force 

 

   

 

 

 

 

20

Coding Transmitters  

 

   

 

 

 

 

     Door 

 

   

 

 

 

 

21

     Courtesy Light 

 

   

 

 

 

 

21

     Vacation Mode 

 

   

 

 

 

 

22

     Auxiliary Output 

 

   

 

 

 

 

22

     Pet Mode 

 

   

 

 

 

 

23

     Erasing Transmitter Codes 

 

   

 

 

 

 

23

     Mounting Wall Transmitter  

 

   

 

 

 

 

23

Accessories  

 

   

 

 

 

 

 

Terminal Block 

 

   

 

 

 

 

24

 

Remote Aerial  

 

   

 

 

 

 

24

 

Wired Wall Switch / Key Switch 

 

   

 

 

 

 

24

        

Battery Back Up Installation 

 

   

 

 

 

 

25

CONTENTS

PA1000V1 Overhead Garage Door Operator

Diamond PD 

Power Drive

 : Instruction Manual

© Copyright 2011

3

PA1000

 

Instruction Manual (Instructions d’installation)

Содержание PA1000V1

Страница 1: ...www bnd com au Part Number 40020 Model PA1000V1 October 2011 FOR RESIDENTIAL USE ONLY Instruction Manual Notice D exploitation PA1000 Overhead Garage Door Operator ...

Страница 2: ...a télécommande Veuillez conserver ces instructions pour future référence To reduce the risk of electric shock this equipment has a grounding type plug that has a third grounding pin This plug will only fit into a grounding type outlet If the plug does not fit into the outlet contact a qualified electrician to install the proper outlet Do not change the plug in any way Pour reduire les risques de c...

Страница 3: ...ing Speed Mode 17 Setting Limits Position 18 Testing Safety Obstruction Force 19 Setting Safety Obstruction Force 20 Coding Transmitters Door 21 Courtesy Light 21 Vacation Mode 22 Auxiliary Output 22 Pet Mode 23 Erasing Transmitter Codes 23 Mounting Wall Transmitter 23 Accessories Terminal Block 24 Remote Aerial 24 Wired Wall Switch Key Switch 24 Battery Back Up Installation 25 CONTENTS PA1000V1 O...

Страница 4: ...tery 27 Safety Beam Option 28 Auto Close Option 28 Courtesy Light 28 Auxiliary Output 28 Vacation Mode 28 Pet Mode 28 Service 28 Maintenance 29 Troubleshooting Guide 30 Parameters 31 Spare Parts List 32 Warranty 34 Optional Accessories 36 CONTENTS PA1000V1 Overhead Garage Door Operator PA1000 Instruction Manual Instructions d installation 4 ...

Страница 5: ...wall transmitter in a location where the garage door is visible but out of the reach of children at a height of at least 5 feet 1 53m Disconnect electric power to the garage door operator before removing covers Door must have Safety Beams fitted Do not wear rings watches or loose clothing while installing or servicing a garage door operator This operator is not suitable for commercial industrial o...

Страница 6: ... extended C Rail Maximum door area 177sq ft 16 5 m2 Maximum door hanging weight 441lbs 200kg Receiver type UHF Multifrequency FM Receiver Receiver code storage capacity 14 X 4 button transmitter codes Transmitter frequency 433 47MHz 433 92MHz 434 37MHz Coding type TrioCode Number of code combinations Over 4 29 billion random codes Code generation Nonlinear encryption algorithm Remote control batte...

Страница 7: ...the full position if anything passes through the beam Soft Start Soft Stop The operator eases into and out of an operating cycle This makes operation smoother and quieter and most importantly reduces wear and tear on the door and operator Courtesy Light The courtesy light automatically switches on for approximately three 3 minutes when operating the door This can also be programmed to turn on and ...

Страница 8: ...he door opener Close Limit Red LED illuminates and flashes when the door is closing and remains steady on when the close limit position has been reached Minus Red Code Set Button is used during installation to help set the close limit position Pressing and holding this button will move the door in the close direction Movement stops when the button is released Code Set LED light flashes when a code...

Страница 9: ... 01 02 03 04 16 15 14 13 12 05 06 07 08 09 10 11 01 02 03 04 05 06 07 08 Fig 01 FORCE MARGIN SET Button Close Limit LED Minus Red CODE SET button Code Set LED LIMIT SET Button Service LED Courtesy light module Connectors Accessories J4 Connector 09 10 11 12 13 14 15 16 Diamond PD Power Drive Instruction Manual Copyright 2011 9 PA1000 Instruction Manual Instructions d installation ...

Страница 10: ...actory Do not adjust the tension of the chain IMPORTANT NOTE If modification to the track length required adjustment must be made only from power head End OR Single Piece Track With Pre Assembled Timing Belt Fig 04 NOTE Timing belt in one piece rail has been tensioned by the factory Do not adjust the tension of the timing belt IMPORTANT NOTE If modification to the track length required adjustment ...

Страница 11: ...de only from power head End OR Multi Piece Knockdown Track With Pre Assembled Timing Belt Fig 06 IMPORTANT NOTE If modification to the track length required adjustment must be made only from power head End Kit contents Fig 05 Fig 06 Diamond PD Power Drive Instruction Manual Copyright 2011 11 PA1000 Instruction Manual Instructions d installation ...

Страница 12: ...Knockdown C Rail Assembly Step 1 Unpack and assemble the C Rail as shown above in Fig 07 Fig 07 PA1000 Instruction Manual Instructions d installation 12 ...

Страница 13: ...p 3 Fix the two track brackets with four screws supplied in accessory pack as shown in Fig 09 Locate shaft into sprocket Shaft 4 Taptite screws S M4 X 10 2 Track brackets VP1 Fig 09 Fig 08 Diamond PD Power Drive Instruction Manual Copyright 2011 13 PA1000 Instruction Manual Instructions d installation ...

Страница 14: ...ith supplied snap pin Fig 12 Leave the drive unit in its packing box for protection during installation Step 7 Securing the Powerhead to the Ceiling Raise the drive unit from the packing box and support it in a horizontal position with a step ladder then open the garage door Rest the operator on the open door and use a scrap piece of wood to bring it to horizontal level Line up the track perpendic...

Страница 15: ...sary Damage to the door panel may occur if the bracket is installed incorrectly on a panel with insufficient strength The door operator warranty does not cover damage caused by the operator to the door and or door panel Step 14 Attaching the Arms Assemble bent and straight arms as shown in Fig 16 with bolts and nuts supplied in accessory pack Then connect assembled arm to the door bracket and the ...

Страница 16: ...e pan head screw 5 supplied Repeat steps a and b to assemble the Safety Beam c PE3 V1 RX receiver Locate the Safety Beam in a strategic location in the d door opening We recommends that the sensor is placed no higher than 6 and no lower than 5 above the floor level Connect as per the wiring diagram Fig 19 Step 15 2 Alignment Power up the PA1000 with the Safety Beam connected a The green LED of the...

Страница 17: ...ugh all three speed modes To change the speed setting use the following steps Engage the C Rail s trolley attached to the door via the a arms with the chain index by moving the door If the trolley does not click firmly onto the chain b index ensure that the manual release cord is not in the disengaged position by pulling it backwards Turn on the power to the operator The c Close Limit LED will be ...

Страница 18: ... garage door will start closing automatically once Step 4 is performed The door will also automatically re open after fully closing with a small pause between the cycles 5 PresstheLimitsetbutton Thisactionwillstoreintomemory the door limit position The door will now automatically close to its limit position then fully open to calculate the safety obstruction forces Please be aware of the above war...

Страница 19: ...le Press the OPERATE button to close the door 1 Fig 23 Press again to open the door When the door is 2 reaching half of the opening distance grab the bottom rail of the door firmly the door should stop If the door does not stop when opening the force may be excessive and need adjusting refer to Step 18 4 Fig 24 Fig 23 IMPORTANT WARNING If the door is closing and is unable to re open when obstructe...

Страница 20: ...Limit LED flashes continuously when the 4 plus button is being pressed this indicates that the maximum force pressure setting has been reached Test the force again as per 5 Step 17 1 and 17 2 above 18 4 To Decrease Force Pressure Fig 26 Press and hold the FORCE MARGIN SET button 1 While holding down the FORCE MARGIN SET button 2 press the Minus Button Each press decreases the force margin The Clos...

Страница 21: ...will start illuminate and the courtesy light will turn on to indicate that the light code learning is active Choose a transmitter button which is not already 2 coded into the receiver Press this button for two seconds and CODE SET LED will begin to flash Press the same transmitter button again The CODE 3 SET LED will illuminate for one second and then go out The transmitter is now coded to operate...

Страница 22: ...ver Press this button for two seconds and the CODE SET LED will begin to flash Press the same transmitter button again The CODE 3 SET LED will illuminate for one second and then do out and the courtesy light will also switch off This indicates that the code has been stored Press Code set Button three times Select one of the four buttons not programmed yet that you wish to use to control the Auxili...

Страница 23: ...he Code Set button is pressed and held on for 6 seconds the LED will blink rapidly for one second to indicate that all programmed codes have been erased 19 7 Installation of Wall Mounted Transmitter Fig 34 IMPORTANT WARNING Locate the Wall Mounted Transmitter Within sight of door At minimum height of 5 feet so shall children are not able to reach it and Away from moving parts of the door To set th...

Страница 24: ...the garage door open If the range is improved with the door open then you can install a remote aerial kit to improve the radio reception Mount the aerial to a suitable location on the outside of the garage The radio receiver in your garage door operator is similar to the receiver in your television set the better the position of the aerial the better the reception will be Where possible mount the ...

Страница 25: ...Fig 37 Reconnect power 8 Testing Battery Back Up Press either the OPERATE button or transmitter to 1 activate the operator Whilst the door is in motion disconnect mains power 2 the operator should continue to operate NOTE Wait for the door to complete its travel before proceeding to the next step Press either the OPERATE button or transmitter to 3 activate the opener Whilst the door is in motion r...

Страница 26: ...im the remote control transmitter through your windscreen If your remote control transmitter has a visor clip it should be secured to the visor so that when the remote control transmitter is operated it is transmitting through the vehicle windscreen Fig 38 Check that the door is fully closed before you drive away If you press the remote control transmitter whilst the door is moving the door will s...

Страница 27: ...he closed position pull down on the string handle on an angle towards the door This will allow you to manually open or close the door To re engage the operator pull the string handle away from the door Warning When the operator is manually disengaged the door is no longer locked To lock the door manually re engage the operator after the door is closed Power Failure When there is a power failure th...

Страница 28: ...te control transmitter must be programmed to operate the Auxiliary Output feature See Step 19 4 for more information Vacation Mode The radio receiver of the garage door operator can be turned off using a remote control transmitter to activate the Vacation Mode facility Whilst in vacation mode the operator will not respond to any remote control transmitter To activate the Vacation Mode facility see...

Страница 29: ... suggest that you contact your nearest Authorised Dealer to perform an annual door service Warranty Expired Indicator When the opener reaches the number of cycles covered by warranty the courtesy light will flash 10 times after each operation to indicate that the warranty has expired This flashing will continue for twenty 20 operations unless the user acknowledges the warranty expiry indicator and...

Страница 30: ...een set Check the door for normal operation see monthly maintenance Plug a device e g a lamp into the power point and check that it is OK Replace the battery Turn off Vacation Mode by pressing transmitter button See remote control transmitter code setting procedure The motor runs but the door does not move The opener is disengaged Re engage the opener The remote control transmitter range varies or...

Страница 31: ...perate function FORCE MARGIN SET PLUS Increases the obstruction force margin setting FORCE MARGIN SET MINUS Decreases the obstruction force margin setting FORCE MARGIN SET then SET Reloads the factory set default obstruction force margin setting Press SET for 6 sec Clears the door limits set positions Limits then need to be reset SET press and hold until all LEDs are off Deletes control parameters...

Страница 32: ...Spare Parts List PA1000 Instruction Manual Instructions d installation 32 ...

Страница 33: ...Diamond PD Power Drive Instruction Manual Copyright 2011 33 PA1000 Instruction Manual Instructions d installation ...

Страница 34: ...Warranty 1 Definitions 2 PA1000 Instruction Manual Instructions d installation 34 ...

Страница 35: ...and keep it together with a copy of the receipt of purchase in a safe place production of such information will assist the handling of a claim made under this warranty Warranty Diamond PD Power Drive Instruction Manual Copyright 2011 35 PA1000 Instruction Manual Instructions d installation ...

Страница 36: ... the door Ideal for mounting inside the house Combo Access Kit Keyswitch function will open the door without a remote control transmitter Can be used to manually disengage the operator recommended when the garage door is the only access to the garage Remote Aerial Kit For sites where radio range may be reduced metal garages Contact your authorized dealer for installation of these accessory items W...

Страница 37: ...Diamond PD Power Drive Instruction Manual Copyright 2011 37 PA1000 Instruction Manual Instructions d installation ...

Страница 38: ...www Copyright October 2011 All Rights Reserved ...