background image

3

www.diyopner.com.au

Pre-Installation Checks

01

fi g

Tools Required

Ladder
Adjustable wrench
Socket set
Drill
Screwdrivers
Marker pen
Door stand

Door Operation

The door must be in good operating 
condition.  

The maximum effort to move the door 
up or down, from stationary, should not 
exceed 20kg of force at the bottom rail.  

Lift the door to about halfway.  When 
released, the door should remain stationary 
and not slide up or down.  

Raise and lower the door to check for 
binding or sticking.

Unsuitable Door Types

Do not install the opener on doors with:

removable mullions (used between 
two adjacent doors)
that incorporate a wicket door (small 
hinged door in the garage door’s 
curtain)
axle diameters that exceed 35mm

Position

The opener can be installed on either the 
right- or left hand side of the door.

This opener must be installed in a dry 
position that is protected from the 
weather. 







Power Supply

Properly earthed 3 pin single-phase power is 
required.

WARNING! 

A portable power generator 

is not recommended due to spikes, 
surges and fl uctuations in the supply.

Side room

The minimum side room required from the 
edge of the door curtain is 40mm to the inside 
of the door bracket, and 85mm to the wall 

(Fig. 01)

.  

If the all of the above 

requirements are not met, 

please contact a garage door 

professional:

(p) 1300 300 625

(w) www.diyopener.com.au

STEP #2

STEP #2

Содержание iOpener RD40

Страница 1: ...s 1 Important Safety Checks 2 Pre Installation Checklist 3 Fitting The Opener 4 Set The Travel Limits 5 Check the Safety Obstruction Force 6 Code The Transmitters Okay let s get started Powered by TRI...

Страница 2: ...fully closed before leaving the driveway DO NOT operate the opener when persons are near the door Children must be supervised at all times when the opener is in use Serious personal injury and or prop...

Страница 3: ...etween two adjacent doors that incorporate a wicket door small hinged door in the garage door s curtain axle diameters that exceed 35mm Position The opener can be installed on either the right or left...

Страница 4: ...lock your door with the locking bars after installing the opener Remove or disable the lock Security is not affected as the opener has an inbuilt locking facility 2 Fit the Weight Bar If the door has...

Страница 5: ...nd Do not tie the ropes too tight as damage to the curtain may ensue This will stop the door unrolling when taken off the bracket At the end where the opener is to be tted support the door with a ladd...

Страница 6: ...he bracket cannot be relocated the opener may be tted onto the axle using the opener s saddle and U bolt as follows Using your reference marks as a guide sit the opener on the door mounting bracket an...

Страница 7: ...e door is near the desired closed position When the door is at the desired close position press the SET button The OPEN LIMIT LED will now ash Press and hold the OPEN button to open the door Release t...

Страница 8: ...closing or stop when opening the force may be excessive and need adjusting a b c a b c 12 g STEP 5 STEP 5 To protect the safety of you and your family it is important to check the opener s safety func...

Страница 9: ...respectively increases or decreases the force margin The OPEN LIMIT LED or CLOSE LIMIT LED will ash each time the OPEN OR CLOSE button is pressed to indicate a force change Test the again as per the a...

Страница 10: ...nd hold both DOOR CODE and CLOSE Fig 18 Press one of the four buttons on the transmitter for two 2 seconds pause fortwo 2 seconds thenpressthesame button again for two 2 seconds Release DOOR CODE and...

Страница 11: ...mitter s button to test a b c d Code The Transmitters 20 g 21 g Deleting Transmitter Codes Deleting a Stored Transmitter Code Select the transmitter to be deleted Press and hold the DOOR CODE Fig 21 P...

Страница 12: ...seconds Setting the Pet Mode position The default Pet Mode height can be changed as follows Make sure the door is closed then press and hold the OPEN button for six 6 seconds Fig 23 until you hear thr...

Страница 13: ...object and should be tested regularly to ensure it is in good condition A poorly maintained door could cause fatal or serious injuries or serious damage to property To ensure a long and trouble free...

Страница 14: ...ory Flat battery Broken battery lead inside transmitter Code transmitter in to openers memory Refer step 6 on page 10 Replace battery Send transmitter to installer or Automatic Technology for repair D...

Страница 15: ...15 www diyopner com au...

Страница 16: ...iveways Boulevard Keysborough Victoria 3173 Australia P 1300 133 944 61 2 9722 5666 International Enquiries Only E sales ata aust com au www ata aust com au August 2011 Automatic Technology Australia...