7

GDO-8 Instruction Manual

7. Pinning the Door

Pinning the Door to the drum:

Pinning the door’s curtain to its drum maintains security when the opener is 

closed. If the curtain is not pinned the door can be partially opened manually.  

a. Fully close the door.

b. Mark a minimum of two (2) drill holes on the drum to each end of the door.

c. Drill holes using 3.2mm (

1

/

8

”) drill bit.  

d. Fit M10 x 32mm screws and washers (not supplied) to each of the four (4) 

holes. This screw should be positioned as low as possible in the grove, but 

make sure that it does not alter the curtain’s normal lead in to the guide.

BALLOONING DOOR

PINNED DOOR

FREE DOOR

Without locking 

bars door can be 

lifted

Door secure and 
will not lift

Pin Points

Screw into the 
low part of 

grove

8. Proping the Door

Prepare the Door:

a. At the end opposite to where the opener will be fitted, check that the U-bolt 

which holds the door axle to the bracket is tightened securely.

b. Open the door completely and tie rope around the door roll. Do not tie the 

rope too tight as damage to the curtain may ensue.  This will stop the door 

unrolling when taken off the bracket

c. At the end where the opener is to be fitted, support the door with a door stand 

or suitable prop. Place a towel between the door and the prop to protect the 

door from damage.

d. At the end where the opener will be fitted use a pencil to mark the position of 

the U-bolt in the door bracket and the position of the door bracket on the wall 

to assist in reassembling.

WARNING! The U-bolt must be done up tightly to ensure 

the stored energy in the springs cannot be unexpectedly 

released.

WARNING!

 

Make sure the prop is 

snug under the door  and is stable.

U-bolts

Towel

Door stand 
or prop

Door 
bracket

Not pinned and 

without locking 

bars door can be 

lifted

Содержание GDO-8 ShedMaster

Страница 1: ...Water Resistant Roll Up Door Opener Instruction Manual GDO 8 ShedMaster Doc 160074_00 Part 13457 Released 25 08 16 ...

Страница 2: ...1 Adjusting Safety Obstruction Force 11 To Increase Force Pressure 11 To Decrease Force Pressure 11 To Recall Factory Set Force 11 To Recalculate Force Margins 11 14 Coding a Transmitter 12 Storing the Transmitter Code 12 Coding a Transmitter to Enable Vacation Mode 12 Coding a Transmitter to the Courtesy Light 12 Remotely Coding Transmitters 13 Erasing a Stored Transmitter Code 13 Erasing All Tra...

Страница 3: ...ons Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm ground that will take the weight without the legs sinking Ensure user has 3 points of contact while on ladder Crush injury from unsecured door Place a 2 metre exclusion zone around area under the door while it is unsecured Do not move under a door while it is on the door support or ladder Follow the instal...

Страница 4: ...2 x PTX 5 Transmitters 4 1 x Weight Bar Fastner Bag 5 2 x Nilock Nut 6 2 x 3 16 x 1 2 flat washers 7 2 x Pan Head Screw M4 x 50 1 2 3 5 6 7 4 Screwdrivers Adjustable End Wrench Sockets and Wrench Pencil Rope Drill Towel Self tapping Screws and Washers M10 x 32mm Stepladder Door Stand or suitable prop 3 Tools Required ...

Страница 5: ... the inside of the door bracket and 85mm to the wall 4 Setup Requirements The Opener a MUST BE installed in a dry position protected from weather Moisture or corrosion not covered by Warranty b Is factory set for RIGHT HAND SIDE installation from inside garage but capable of LEFT HAND SIDE installation c REQUIRES properly earthed 3 pin single phase power within an arms length of door and at a suit...

Страница 6: ... Pan Head Screw 7 and the two 2 Flat Washer 6 and the two 2 M4 Nilock Hex nut 5 d Check that the door is still balanced and smooth If not then the door may require servicing 4 2 7 5 Door Preparation Prepare the Door a Clean the guides if there is any oil or wax present using a suitable white spirit The only lubricant suitable for use on door guides is silicon spray DO NOT use WD 40 RP 7 petroleum ...

Страница 7: ...r a At the end opposite to where the opener will be fitted check that the U bolt which holds the door axle to the bracket is tightened securely b Open the door completely and tie rope around the door roll Do not tie the rope too tight as damage to the curtain may ensue This will stop the door unrolling when taken off the bracket c At the end where the opener is to be fitted support the door with a...

Страница 8: ...r rotates freely by pulling the string handle down there will be a click to disengage opener Then move the forks from side to side by hand c Slide the opener over the door axle and into the drum of the door as shown d Push the opener in as far as possible without interfering with the curtain SO ONE OF THE DOOR DRUM S WHEEL SPOKES IS BETWEEN THE OPENER S DRIVE FORKS e Raise the door off the door st...

Страница 9: ... slowly until the yellow status LED just illuminates NOTE If the status LED is already illuminated when power is connected then turn the datum adjust screw until the LED goes off then turn back one notch to illuminate again WARNING The safety obstruction detection system is inoperable if the MINUS and PLUS buttons are used to drive the door and travels limits are not set 10 Setting the Datum ...

Страница 10: ...he door closer to the ground c If the door overshoots press the PLUS button to move the door in the open direction d When the door is at the desired close position press the SET button the PLUS LIMIT LED will now flash e Press and hold the PLUS button until the door reaches your desired open limit position Single presses of the PLUS button will inch the door open f If the door overshoots press the...

Страница 11: ...extreme temperature changes To Increase Force Pressure a Hold down the FORCE MARGIN SET button b While holding the FORCE MARGIN SET button press the OPEN button Each press will increases the force margin c The PLUS LIMIT LED will flash each time the PLUS button is pressed to indicate an increase in force d If the PLUS LIMIT LED flashes continuously when the PLUS button is being pressed this indica...

Страница 12: ...press it again and hold will beep two times on second press e Press one of the four 4 buttons on the transmitter for two 2 seconds pause for two 2 seconds then press the same button again for two 2 seconds f Release DOOR CODE button g Press and hold the transmitter button for six 6 seconds to set Vacation Mode The door code LED will stay lit while Vacation Mode is active h To reset Vacation Mode p...

Страница 13: ...ng a Stored Transmitter Code a Select the transmitter you want to delete b Press and hold the DOOR CODE BUTTON c Press the transmitter button you would like to delete for two seconds pause for two seconds press again for two seconds and then release d Release the DOOR CODE BUTTON The code should now be deleted Confirm this by pressing the transmitter button the function e g door opening should not...

Страница 14: ... tension and can cause serious personal injury DO NOT attempt any garage door adjustment DO NOT use if repair or adjustment is needed Call for a professional garage door service CAUTION Emergency access If your garage has no pedestrian entrance door an emergency access device should be installed This accessory allows manual operation of the garage door from outside in case of power failure Entrapm...

Страница 15: ...easy to operate No more than 15 kg of force should be required to disengage the door using the manual release cord If excessive force is required reset the close limit position Section 11 Resetting Door Limits 17 Operating your Opener To Operate the opener a Press the programmed transmitter button until your door begins to move usually 2 seconds Make sure you can see the door when you use the tran...

Страница 16: ... on when the open limit position has been reached 5 DOOR STATUS LED Yellow Illuminates when Service is due 6 MINUS LED Red Illuminates and flashes as the door opens closes and remains on when the close limit position has been reached Door Status Indicators PLUS LED green MINUS LED red Beeper Open On Close On Opening Flashing Closing Flashing Door travel stopped Flashing Flashing Door obstructed wh...

Страница 17: ... 12kg Receiver type Multi frequency UHF FM 433 47 433 92 434 37MHz Receiver code storage capacity 8 X TriocodeTM 128 4 button Transmitters Coding System TrioCodeTM 128 Type Coding type Code Hopping Number of code combinations Over 100 billion random codes Transmitter battery CR2032 3 Volts Courtesy light Light Module Optional Network connectivity Not Available Note Intermittent operations may occu...

Страница 18: ...restricted Variations are normal depending on conditions e g temperature or external interference The battery life is exhausted Position of the transmitter in the motor vehicle Make sure you can see the door when you use the transmitter Check the battery status by pressing a button flashing or no light requires battery to be changed Aim the transmitter through the windscreen The door reverses for ...

Страница 19: ...ut 10 15 secs then reconnect power If Red LED is flashing limits are not set Reset Limits 21 Troubleshooting If You Need a Service Call If the opener needs a service please call the dealer who installed the garage door opener their contact details are usually on a sticker on the back of your garage door For product assistance contact 1300 133 944 within Australia BEFORE CALLING you should have the...

Страница 20: ...l benefits WARNING Prior to disposal recycling or collection all battery terminals must be securely insulated with a non conductive material to prevent any two batteries from short circuiting and generating heat during storage or transport Battery terminals may be insulated with electrical tape or batteries may be individually packaged in a non conductive material e g plastic bag or original packa...

Страница 21: ...21 GDO 8 Instruction Manual 25 Service Schedule Year Approx Cycles Date Details 1 3 000 2 6 000 3 9 000 4 12 000 5 15 000 ...

Страница 22: ...n fuses electrical surges power surges or power spikes e theft fire flood rain water lightning storms or any other acts of God f any installation configuration or use of the Product contrary to the instructions supplied with the Product g maximum continuous operating time exceeding 1 minute in 10 h the operating force exceeding 15kg 150 Newton when moving the door manually to the open or closed po...

Страница 23: ...mitter Allows you to operate the opener within 10 metres of the door Ideal for mounting inside the house Wireless Keypad The entry keypad allows entry to the garage without using a transmitter 27 Optional Accessories There are a range of additional accessories for your added convenience and security Contact your Dealer for installation of these accessory items IMPORTANT NOTE Only TrioCode TM 128 T...

Страница 24: ...Is your door sticking and hard to operate It may be time for a service for more details see section 22 For a service contact your dealer using the details below Dealer ...

Отзывы: