The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using it for any purpose other than the
use of the products or the execution of the project to which it refers, and from communicating it to third parties without Automatic Systems’ prior written agreement.
Document subject to change without notice.
First
Lane
-MT-EN
p.
10 / 48
T
ECHNICAL
S
PECIFICATIONS
FL 960
FL 970
Power supply:
Single phase 120 VAC (5A) to 240 VAC (3A) -
(+/-10%) -
50/60 Hz + Ground
The power supply must be protected by a 16 A circuit
b 30 mA differential circuit breaker.
AISI 304L brushed stainless steel housing, 1.5 mm thick.
Steel frame with RoHS zinc-plated corrosion resistance.
Tempered safety glass obstacles (fixed and mobile), 10 mm thick.
Passage width (L):
600 mm 900 mm
Weight:
right unit:
104 kg
106 kg
left unit:
103 kg
105 kg
intermediate unit:
122 kg
127 kg
Power consumption (per lane):
At rest:
20 W
During operation:
35 W
Maximum:
80 W
Motor (2 motors per lane):
24 VDC –Nominal output power:
86 W
Operating time:
Opening:
0.7 sec
1 sec
Closing:
0.7 sec
1 sec
(depending on the access control system reactivity and the user speed)
Ambient temperature during use:
+0 to +50 °C
Ambient relative humidity during use, non-condensing:
< 95%
Protection rating (IP)
40
Sound level (at 1 m distance):
55 dB
MCBF (mean cycles between failures), with recommended maintenance:
2,000,000
Conforms to
standards