Automated Logic UNI/32 Скачать руководство пользователя страница 7

Revised 11/26/01 • UNI/32

7

© 2001 Automated Logic Corporation

NOTE

Since a failed download indicates 

a system problem, you should never clear 
a failure. Locate and resolve the problem, 
then retry the download.

6. Click the Properties button to refresh the 

screen. This removes the items from the 
Download Items list.

Transferring Memory in SuperVision

If you are using SuperVision to transfer 
memory, you must use SuperVision version 
2.6b or later, FBLINK version 2.7a or later, and 
the UNM module driver. For more information 
about using SuperVision, refer to the 

SuperVision User’s Guide

.

The first memory transfer to the UNI/32 takes 
longer than subsequent memory transfers.

1. Connect your workstation or portable 

computer to the UNI/32. Refer to 
“Communicating with the Workstation 
Using SuperVision” on page 8
.

2. Navigate to the module driver and look at 

the module status report in SuperVision to 
make sure the module type and number 
agree with the module.

• To view the module status report in 

SuperVision v3.0, click Tools-
Troubleshooting-Module Status.

• To view the module status report in 

SuperVision v2.6b, press the Esc key, 
type

 MO  , , module address,15 

and press Enter.

3. Transfer memory to the module.

• In SuperVision v3.0, click Tools-

Troubleshooting-Transfer Memory to 
Module.

• In SuperVision v2.6b, choose Download 

Memory for This Module.

4. When the memory transfer is finished, 

check the module status report again. 

Make sure the FB List on this page shows 
all the FBs you intended to transfer.

Using Flow Sensors

The UNI/32 supports U-cards that use flow 
sensors. You must calibrate each sensor to 
ensure accurate readings. You must also set 
the type of U-cards and flow sensors that are 
being used by each FB on the module driver 
Properties page in WebCTRL or Parameter 
page in SuperVision.

• If you are running a WebCTRL system, 

configure the type of U-card and flow 
sensor on the Airflow microblock 
Properties page for each FB that uses a 
flow sensor. Refer to the 

DRV_UNI16 

and DRV_UNI32 Module Driver

 

document for details.

• If you are running a SuperVision 

system, configure the type of U-card 
and air sources on the module driver 
Parameter page. Refer to the 

UNM 

Module Driver

 document for details.

For more information on calibrating, 
see the 

Test and Balance Technical 

Instructions

.

Troubleshooting Tips

If you are having trouble communicating with 
the UNI/32, check these items before 
contacting Technical Support.

• Make sure the U-Line wiring is correct. 

In more complex systems, make sure 
that all cables involved are attached 
correctly.

• Make sure the UNI/32 and the U-cards 

have power and are turned on. In more 
complex systems, make sure all 
equipment has power and is turned on. 
Some devices, especially 
communication devices, receive power 
from a source other than a power cable 
or adapter (for example, some devices 

Содержание UNI/32

Страница 1: ...and and product names are trademarked by their respective companies Technical Instructions UNI 32 Using the UNI 32 2 Specifications 2 Mounting 3 Power Wiring 3 Communicating with the UNI 32 4 Connecting the UNI 32 to the U cards 4 Connecting the UNI 32 to an ARC156 MS TP or Legacy CMnet network segment 5 Addressing 5 Transferring Memory 6 Transferring Memory in WebCTRL 6 Transferring Memory in Sup...

Страница 2: ...pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this eq...

Страница 3: ... from being powered up before the proper voltage is verified 2 Make sure the 24VAC power source is off 3 Connect the power wires to the module s power terminals labeled Ground and 24VAC 4 Apply power to the transformer 5 Make sure that 24VAC is present at the module s power input terminals 6 Set the module s address Refer to Addressing on page 5 for details about setting the address 7 Turn the mod...

Страница 4: ...odule driver Properties page in WebCTRL or Parameter page in SuperVision Refer to the appropriate module driver document for more information Automated Logic Corporation recommends a specific wire for both power and communications on the Unet This wire which contains a pair of 14AWG wires for power and a pair of 22AWG wires for communication is available from Magnum Cable Corporation Cleveland OH ...

Страница 5: ...18AWG twisted pair wire for legacy CMnet EIA 485 wiring For more information about CMnet wiring refer to the Technical Handbook or to the ARC156 CMnet Wiring Technical Instructions To set the baud rate at 156 kbps when using an ARC156 CMnet set the baud rate jumper to Arc156 see Figure 5 To set the baud rate at 38 4 kbps set the baud rate jumper to 9600 38 4K and set the first switch on the eight ...

Страница 6: ...formation NOTE This type of download should be performed with caution When the module is automatically restarted before and after transferring memory any equipment controlled by the module is shut down and restarted Downloading memory also overwrites all Function Blocks in the module causing the module to lose any stored data Transferring Memory in WebCTRL If you are using WebCTRL to transfer memo...

Страница 7: ...oad Memory for This Module 4 When the memory transfer is finished check the module status report again Make sure the FB List on this page shows all the FBs you intended to transfer Using Flow Sensors The UNI 32 supports U cards that use flow sensors You must calibrate each sensor to ensure accurate readings You must also set the type of U cards and flow sensors that are being used by each FB on th...

Страница 8: ...IA 232 port of the APT using a standard straight through serial cable 2 Set the APT s Mode Select switch On an ARC156 network segment use the TTL setting On a legacy CMnet use the 485 setting 3 Connect the Access port of the APT to the Access port of the module 4 In SuperVision define the connection type using Table 1 Formatting the Module If you are unable to communicate with a module after trans...

Страница 9: ... normal Production Date To determine when a module was manufactured check the module status report for the module in SuperVision Refer to the WebCTRL User s Guide or the SuperVision User s Guide for more information about the module status report Table 2 LED Signals Run LED Error LED Condition 2 flashes per second Off Normal 2 flashes per second 1 flash then pause Normal but module is alone on the...

Страница 10: ...ation A sticker on the back of the module also shows the date the module was manufactured The first three characters on the sticker indicate the type of module The next two characters show the year and month of manufacture The month digit is in hexadecimal ...

Отзывы: