![Autodesk Combustion 4 discreet Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/autodesk/combustion-4-discreet/combustion-4-discreet_network-manual_3021206034.webp)
Networking Quick Start and Troubleshooting
6
30
4.
Click the Config Services tab.
5.
In the Service Name drop-down list, verify that
the service you want to use to manage
combustion
licenses is selected.
Note:
If you have more than one software vendor
using FLEXlm for license management, this drop-
down list will have more than one option.
By default, the service is named “FLEXlm Service
1”. All Autodesk products will have to use the
same service, so consider naming the service
something recognizable and sensible to you, like
“Autodesk Product Licenses.” Whatever the
name, simply type it in this field.
6.
Enter the path to the license manager daemon
(
lmgrd.exe
). The default path where this daemon
is installed is
C:\Program Files\Autodesk Network
License Manager
folder.
Note:
If you are using distributed servers, the
location of the license manager daemon and the
license file can vary depending on your
configuration.
7.
Enter the path to the license file. The default path
where the license file is saved is
C:\Program
Files\Autodesk Network License Manager\License
or in the
License
folder in the directory where you
installed the AdLM.
8.
(Optional) Enter the path where you want the
debug log to be located. You will first have to
create a text file to contain logging information.
9.
To start
lmgrd.exe
automatically when the system
starts, enable Start Server at Power Up.
Note:
Use Services must be active before you can
turn on Start Server At Power Up.
10.
To run
lmgrd.exe
as a Windows 2000 service,
enable Use Services.
11.
Click Save Service to save the new configuration
under the service name specified in step 5.
12.
Click the Start/Stop/Reread tab.
13.
Click Start Server to start the license server.
After a few seconds, the license server will be
running and ready to respond to client requests.
14.
Ensure each client workstation can connect to the
server, and that each client workstation has a copy
of
combustion
configured to look for network
licenses.
Troubleshooting Problems
This section presents suggestions for avoiding and
troubleshooting installation and startup issues that
may arise when you install or start
combustion
from a network or client deployment image.
This document is arranged by network issues
divided into two categories: License Management
and Program Execution. In each category, a
description of how the program is designed to
function is provided as well as possible problems
and their resolutions.
This information applies to all Autodesk products
that use AdLM with FLEXlm technology. For
simplicity, the chapter refers to, but is not limited to,
combustion
.
License Management
combustion
uses the new Intel port of the AdLM.
AdLM is a software-based TCP/IP dependent
license management system. This means that no
external authentication devices are required, and
that Microsoft TCP/IP must be installed and
configured on all
combustion
workstations and
license servers.
Once the AdLM has been installed, the following
steps must be performed in a specific order before it
will be available to issue licenses to
combustion
workstations.
Содержание Combustion 4 discreet
Страница 1: ...del 11 March 2005...
Страница 5: ...1 R e q u i r e m e n t s Summary System Requirements 2 Network Installation Components 3...
Страница 16: ...Network Planning Concepts 2 12...
Страница 17: ...13 Installation Summary FLEXlm 14 Setting up the Network 14 Silently Installing combustion 15...
Страница 22: ...Installation 3 18...
Страница 26: ...License Server Configuration 4 22...
Страница 30: ...Administration 5 26...
Страница 38: ...Networking Quick Start and Troubleshooting 6 34...
Страница 39: ...35 G l o s s a r y...