*Note: No security time control for the first refilling
8.
Why is the water level always a little higher than the sensor? Is the
sensor
broken?
There are several possibilities.
1) The siphon break is not installed properly.
2) The water inlet and the sensor are not in the same reservoir.
3) The tubing is long, so the water in the tubing still fills into the tank after the
pump stops.
4) The sensor is mounted in a small sump/tank. It will stop the pump one
seconds after it detects water, but the one-second filling is more obvious in a
small sump/tank than that in a big one.
You can follow the steps below to test if the sensor works properly.
i.
Cut off the power and mount the sensor above the water line.
ii.
Move the outlet of the tubing to an empty container.
iii.
Connecting the power, waiting for the pump works.
iv.
Put the sensor in the water to see if the pump stops.
If the pump stops, it means the sensor works properly. If it does not, please fill
in the contact us form. We will contact you as soon as possible.
9.
Why does the red LED flash with audible alert? I have checked the
water reservoir and the bubble but there is no problem.
The QST memory is not set correctly. Please unplug the power cable, then mount
the sensor at the normal water level before connecting the power and do not
move it afterwards. If you want to move the sensor or change the water level,
you have to repeat the above steps.
10.
How to use other pumps with Smart ATO micro?
You can use a pump which meets your requirement with our Smart AC Socket:
http://autoaqua.com.tw/en/accessories/SAC-10.html
Just connect Smart AC socket with the controller, then plug the pump's power
adapter in it.
11.
How to extend the cable length of the pump/solenoid valve/power
supply?
You can use the extension cable. We have 6.7 ft (200 cm) and 16.7 ft (500 cm)
available.