background image

Smart ATO micro FAQ AUG. 2018 v.2 

 

Copyright ©2018 AUTOAQUA Technologies Co., Ltd. All rights reserved

 

 

 

 
 

*Note: No security time control for the first refilling

 

 

8.

 

Why is the water level always a little higher than the sensor? Is the 
sensor

 

broken?

 

There are several possibilities. 

 

1) The siphon break is not installed properly. 

 

2) The water inlet and the sensor are not in the same reservoir.

 

3) The tubing is long, so the water in the tubing still fills into the tank after the 

pump stops. 

 

4) The sensor is mounted in a small sump/tank. It will stop the pump one 

seconds after it detects water, but the one-second filling is more obvious in a 

small sump/tank than that in a big one.

 

You can follow the steps below to test if the sensor works properly. 

 

i.

  Cut off the power and mount the sensor above the water line. 

 

ii.

  Move the outlet of the tubing to an empty container. 

 

iii.

  Connecting the power, waiting for the pump works.

 

iv.

  Put the sensor in the water to see if the pump stops.

 

If the pump stops, it means the sensor works properly. If it does not, please fill 

in the contact us form. We will contact you as soon as possible.

 

 

9.

 

Why does the red LED flash with audible alert? I have checked the 
water reservoir and the bubble but there is no problem.

 

The QST memory is not set correctly. Please unplug the power cable, then mount 

the  sensor  at  the normal  water  level  before  connecting the  power and do not 

move it afterwards. If you want to move the sensor or change the water level, 

you have to repeat the above steps.

 

 

10.

 

How to use other pumps with Smart ATO micro?

 

You can use a pump which meets your requirement with our Smart AC Socket:   

http://autoaqua.com.tw/en/accessories/SAC-10.html

 

Just connect Smart AC socket with the controller, then plug the pump's power 

adapter in it. 

 

 

11.

 

How to extend the cable length of the pump/solenoid valve/power 
supply?

 

You can use the extension cable. We have 6.7 ft (200 cm) and 16.7 ft (500 cm) 

available. 

 

Содержание Smart ATO micro

Страница 1: ...he reservoir is empty 6 Can Smart ATO micro still work if the glass is not transparent 7 How does the redundancy work for the Smart ATO micro 8 Why is the water level always a little higher than the sensor Is the sensor broken 9 Why does the red LED flash with audible alert I have checked the water reservoir and the bubble but there is no problem 10 How to use other pumps with Smart ATO micro 11 H...

Страница 2: ...om happening They have a small hole which allows air in to cut the water flow when the pump turns off Also water drops out of the hole of the siphon break which is properly installed are normal when the pump s on 3 What will happen if the siphon break is not set up properly First when the siphon break is set outside of the reservoir e g between the tank sump and the reservoir or inside of the tank...

Страница 3: ...r is empty no water is refilled in the tank sump and the refilling time will be over three times longer than the first refilling time Consequently it will trigger an alert 6 Can Smart ATO micro still work if the glass is not transparent Yes Since the water level senor of Smart ATO micro is inside of the tank sump the surface will not be a factor that influences the sensing of water level 7 How doe...

Страница 4: ...i Connecting the power waiting for the pump works iv Put the sensor in the water to see if the pump stops If the pump stops it means the sensor works properly If it does not please fill in the contact us form We will contact you as soon as possible 9 Why does the red LED flash with audible alert I have checked the water reservoir and the bubble but there is no problem The QST memory is not set cor...

Страница 5: ...n accessories DC 255 html Extension cable of power supply 6 7 ft 200 cm http autoaqua com tw en accessories DC 212 html 16 7 ft 500 cm http autoaqua com tw en accessories DC 215 html 12 Can I use the solenoid valve with Smart ATO micro How to install it Yes The solenoid valve can be in ATO pump s place It is recommended using with filtered water instead of tap water or it will be clogged Please re...

Страница 6: ...rt ATO micro FAQ AUG 2018 v 2 Copyright 2018 AUTOAQUA Technologies Co Ltd All rights reserved 13 How to purchase accessories Please contact our local distributors http autoaqua com tw en distributors html ...

Отзывы: