9-22
FITTED EQUIPMENT
Fridge (Technical data)
Model. ...................................................................... ………………………………………..... N104
Gross volume, incl freezer… ......................................................................................... 105 litres
Freezer compartment capacity…… ................................................................... ………... 11 litres
Electricity consumption / 24 hr……… ......................... …….... 2.8kW (average at 25
o
C ambient)
Gas consumption / 24 hr……………… ....................... ………0.33 kg (average at 25
o
C ambient)
Fridge/Freezer (Technical data)
Model. .................................................................... ………………………………………..... N3150
Gross volume, incl freezer… ......................................................................................... 149 litres
Freezer compartment capacity…… .................................................................. ………... 25 litres
Electricity consumption / 24 hr……… ......................... …….... 4.0kW (average at 25
o
C ambient)
Gas consumption / 24 hr……………… ....................... ………0.42 kg (average at 25
o
C ambient)
Troubleshooting
In case of a problem an error code on the control panel can light up. When error codes 1, 2, 4, 5,
8, 9, 12 or 13 are visible, directly contact your dealer or a Thetford Service Centre.
For error codes below, first read the according instructions. If this will not solve the problem,
contact your dealer or a Thetford Service Centre.
3
The refrigerator does not work on gas:
•
Check if the gas bottle is not empty.
•
Check if the valve of the gas bottle and all shut-off valves are open.
•
Switch the refrigerator off and on again.
•
Try to run the refrigerator on another power source.
6
The refrigerator does not work on 12V:
•
Make sure the engine is running.
•
Try to run the refrigerator on another power source.
7
The refrigerator does not work on 12V:
•
Make sure the engine is running.
•
Try to run the refrigerator on another power source.
10 The refrigerator does not work on 230V:
•
Check if the mains is available.
•
Try to run the refrigerator on another power source.
11 The refrigerator does not work in AUTO mode:
•
Check if the sources are connected.
•
Try to run the refrigerator on another power source.
18 All symbols on the control panel light up:
•
Wait a few seconds until the refrigerator starts normal.
Содержание Broadway FB
Страница 2: ...DATA RECORD ...
Страница 10: ...2 4 MOTORHOME CODE ...
Страница 16: ...5 2 ARRIVAL AT SITE ...
Страница 24: ...6 8 SAFETY SECURITY ...
Страница 34: ...7 10 CONNECTION OF SERVICES Broadway FB Ventilation Diagram Broadway EL Duo Ventilation Diagram ...
Страница 59: ...7 35 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Страница 60: ...7 36 CONNECTION OF SERVICES ...
Страница 93: ...9 29 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT BROADWAY EL DUO ...
Страница 94: ...9 30 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT BROADWAY FB ...
Страница 99: ...9 35 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY BROADWAY EL DUO ...
Страница 100: ...9 36 FITTED EQUIPMENT SINGLE BED ASSEMBLY BROADWAY EL DUO ...
Страница 101: ...9 37 FITTED EQUIPMENT DOUBLE BED ASSEMBLY BROADWAY EL DUO ...
Страница 103: ...9 39 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY BROADWAY FB ...
Страница 104: ...9 40 FITTED EQUIPMENT DOUBLE BED ASSEMBLY BROADWAY FB ...
Страница 108: ......
Страница 128: ...12 10 SERVICE DETAILS ...
Страница 130: ...13 2 NOTES Designed and Printed by Preset Graphics HB1103 MY 2013 Ref 21301 ...