9-15
FITTED EQUIPMENT
Draining the water heater
Switch off power to water pump (main or
pump switch).
Open hot water taps in kitchen and
bathroom.
In order to check the water that is flowing out,
place an appropriate container (capacity 10
litres) beneath the drain valve (FrostControl)
drainage muff (x).
Turn the rotary switch on the drain valve by
180º until it engages, whereby the push
button moves out and the drain valve opens.
Check whether all of the water in the boiler
(10 litres) has been drained into the container
via the drain valve.
There shall be no claims under guarantee for
damage caused by frost!
Maintenance
Only original Truma parts may be used for
maintenance and repair work!
The materials in the device that come into
contact with water are drinking water safe.
Bio-film, deposits and limescale must be
removed using chemicals to protect the unit
from infestation by micro-organisms. Only
Chloride-free products must be used in order
to prevent damage to the unit.
The effectiveness of the use of chemicals to
combat micro-organisms in the unit can be
increased by heating the water in the boiler to
70ºC at regular intervals.
To do this, on the control panel, select Gas
Operation, then select Summer Operation
60ºC.
Note:
Once the water in the boiler has
reached a temperature of 60ºC, the burner
will switch off. The unit must stay switched on
for at least 30 minutes and no warm water
may be removed. The residual heat in the
heat exchanger will heat the water up to
70ºC.
Fuses 12V
The fuse is in the electronics beneath the
connection cover. Replace the unit’s fuse
only with an identical fuse.
Device fuse: 10A - slow - (T 10A).
Fuses 230V
CAUTION:
The fuse and the power supply
lines must only be replaced by an expert!
WARNING: The unit must be
disconnected from the mains (all poles)
before opening the electronic housing
lid.
The fuse in the power electronics (16)
beneath the electronic housing lid.
This fine fuse must always be replaced with
a fuse of the same type: 10A, slow,
interrupting capacity “H”.
Содержание Broadway FB
Страница 2: ...DATA RECORD ...
Страница 10: ...2 4 MOTORHOME CODE ...
Страница 16: ...5 2 ARRIVAL AT SITE ...
Страница 24: ...6 8 SAFETY SECURITY ...
Страница 34: ...7 10 CONNECTION OF SERVICES Broadway FB Ventilation Diagram Broadway EL Duo Ventilation Diagram ...
Страница 59: ...7 35 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Страница 60: ...7 36 CONNECTION OF SERVICES ...
Страница 93: ...9 29 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT BROADWAY EL DUO ...
Страница 94: ...9 30 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT BROADWAY FB ...
Страница 99: ...9 35 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY BROADWAY EL DUO ...
Страница 100: ...9 36 FITTED EQUIPMENT SINGLE BED ASSEMBLY BROADWAY EL DUO ...
Страница 101: ...9 37 FITTED EQUIPMENT DOUBLE BED ASSEMBLY BROADWAY EL DUO ...
Страница 103: ...9 39 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY BROADWAY FB ...
Страница 104: ...9 40 FITTED EQUIPMENT DOUBLE BED ASSEMBLY BROADWAY FB ...
Страница 108: ......
Страница 128: ...12 10 SERVICE DETAILS ...
Страница 130: ...13 2 NOTES Designed and Printed by Preset Graphics HB1103 MY 2013 Ref 21301 ...