Auto Meter Spek Pro Скачать руководство пользователя страница 1

Programming Instructions for : Pressure 

1/16

Spek Pro Fuel Rail Pressure Gauge

Refer to the “Flow Chart Programming Instructions” while reviewing this guide.

Gauge is field programmable by the operator while installed in the vehicle. This programming is  

accessed by pressing the control buttons located on the face or the meter dial, 

ONE AT A TIME

. The 

“Down” and “Up” buttons move the pointer to a desired setting or controls the faceplate illumination. 

NORMAL/DIAL BRIGHTNESS

PEAK PLAYBACK

HIGH RED-LINE SETTING

LOW THRESHOLD SETTING

C

O

L

O

R

 

S

C

H

E

M

E

DIAL BRIGHTNESS

OPTION:RESTORE FACTORY DEFAULT 

OPTION:DEMO MODE

OPTION:ADJUST POINTER BRIGHTNESS

         

MAIN MENU

SUBMENU

PRESS “MODE” BUTTON TO PROGRAM LEVEL. THEN PRESS BOTH CENTER AND 

LEFT OR CENTER AND RIGHT BUTTONS FOR FIVE SECONDS TO ENTER SUBMENU

DOWN      MODE        UP

+

OPTION: CALIBRATE GAUGE TO ENVIROMENT

Содержание Spek Pro

Страница 1: ...he meter dial ONE AT A TIME The Down and Up buttons move the pointer to a desired setting or controls the faceplate illumination NORMAL DIAL BRIGHTNESS PEAK PLAYBACK HIGH RED LINE SETTING LOW THRESHOLD SETTING COLOR SCHEME DIAL BRIGHTNESS OPTION RESTORE FACTORY DEFAULT OPTION DEMO MODE OPTION ADJUST POINTER BRIGHTNESS MAIN MENU SUBMENU PRESS MODE BUTTON TO PROGRAM LEVEL THEN PRESS BOTH CENTER AND ...

Страница 2: ...r Mode button to save the setting and advance to LOW THRESHOLD SETTING 4 LOW THRESHOLD SETTING Set the Minimum Threshold Sets the point at which LOW warning threshold is reached for that specific gauge The Down and Up buttons will move the dial pointer to select the LOW THRESHOLD SETTING During normal operation the gauge constantly monitors the sensor value and compares it to the LOW threshold If ...

Страница 3: ...and RIGHT buttons for 5 seconds The dial pointer will step 5 times and return to zero 0 All user programmed setting will be erased and the gauge will return to NORMAL OPERA TION OPTION DEMO MODE Displays the features of the meter The pointer goes up and down the scale the dial colors change and the HI LOW and PEAK warning indicators light The DEMO MODE does not time out If the gauge is turned off ...

Страница 4: ...ILL NOT TIME OUT UNTIL THE CENTER MODE BUTTON IS PRESSED IF THE GAUGE IS TURNED OFF IN THE DEMO MODE IT WILL START UP IN THE DEMO MODE TO RESTORE FACTORY DEFAULTS PRESS THE MODE BUTTON ONCE TO ENTER THE PEAK PLAYBACK THEN PRESS AND HOLD THE MODE AND UP BUTTONS FOR FIVE SECONDS YOUR PROGRAMMING WILL BE ERASED BUT FACTORY PROGRAM WILL NOT BE AFFECTED THE GAUGE FACEPLATE WILL FLASH ALTERNATELY RED TH...

Страница 5: ...RESSURE SETTING Sets the value at which the Low Pressure Warn ing is reached The dial faceplate will flash RED for 60 seconds and then stay lit Press the LEFT or RIGHT buttons to select the Low Pres sure Setting Press the center button to save and advance to COLOR SCHEME COLOR SCHEME Press down and up buttons to select a color scheme OFF VIOLET BLUE GREEN YELLOW ORANGE RED WHITE Press the center b...

Страница 6: ...l move Press the center button to return to NORMAL DIAL BRIGHTNESS PRESS BOTH PRESS BOTH Calibrate Gauge to Environment Turn the ignition ON with the engine OFF While in the Normal Mode press and hold the CENTER and LEFT but tons for five 5 seconds The dial face plate will flash GREEN rapidly Press the CENTER mode button to save the setting and return to NORMAL OPERA TION Default Pressure Settings...

Страница 7: ... OPTIONAL OUTPUT CONTROL MODULE INSTALLATION INSTRUCTIONS 1 DISCONNECT NEGATIVE BATTERY TERMINAL 2 VARIOUS MOUNTING SOLUTIONS ARE PRESENTED BY PROPARTS DASH INSTALLATION SELECT LOCATION IN THE DASH TO MOUNT GAUGE AND CUT A 2 1 16 HOLE USE A FILE TO INCREASE THE HOLE SIZE IF REQUIRED BE SURE THERE IS SUFFICIENT ROOM BEHIND THE HOLE FOR THE METER CASE AND THE CONNECTORS YOU WILL USE 3 IF A SUITABLE ...

Страница 8: ...D TO SHORT CIRCUIT THAT COULD CAUSE ENGINE DAMAGE 9 CONNECT THE RED 12 VOLT SUPPLY WIRE TO ON CIRCUIT THAT GETS POWER WHEN THE IGNITION IS TURNED ON THIS CIRCUIT MUST BE FUSED BEFORE THE IGNITION SWITCH 3 AMP FAST ACTING FUSE 10 CONNECT THE BLACK WIRE TO A GOOD GROUNDING POINT ON THE CAR S CHASSIS 11 CONNECT THE WHITE WIRE TO THE DIMMER VOLTAGE GOING TO THE DASH LIGHTS 12 PLUG THE WIRING HARNESS I...

Страница 9: ...SIGNAL IS GENERATED THIS CAN BE USED TO SWITCH ON A RUGGED 35 AMP RELAY TO ACTIVATE A LOW OIL ENGINE KILL ALARMS CUT THROTTLE BODY SENSOR TO DEFUEL KILL BOOST VALVE WARNING OUTPUT CONTROL MODULE NOT TO EXCEED 1 5 AMPS AT 12 VOLTS DC WARRANTY WILL BE VOID IF INCREASED OUTPUT VOLTAGE OR CURRENT IS APPLIED A To Output Control Module A To Red Ignition Switch 12VDC Pin 2 Fuel Pressure Input Green Wire ...

Страница 10: ...essure 2 1 16 Spek Pro Fuel Rail Pressure Gauge 10 1 2 3 4 5 6 7 8 9 10 11 12 J1 CONNECTOR TROUBLESHOOTING THE GAUGE FACEPLATE WILL FLASH ALTERNATELY RED THEN GREEN IF THE FUEL PRESSURE SENSOR AND OR WIRING HARNESS ARE NOT COMMUNICATING WITH THE GAUGE ...

Страница 11: ...IONS OR WIRES ALL ELECTRICAL CONNECTIONS USE SOLDER LESS CONNECTORS AND INSULATE ALL CONNECTIONS WITH ELECTRICAL TAPE AVOID WIRING NEAR ENGINE EXHAUST SYSTEM TURBINE OR ANY AREA THAT MAY RE SULT IN DAMAGE DISCONTINUE USE OF THE PRODUCT IF SMOKE OR A STRANGE ODOR IN PRESENT CAUTION PROPARTS LLC IS NOT RESPONSIBLE FOR INCORRECT INSTALLATION OR PROGRAMMING OF SPEK GAUGES OR CONTROLLERS SPEK GAUGES AN...

Страница 12: ...Wiring Installation Instructions for Pressure 2 1 16 Spek Pro Professional Racing Gauge ...