background image

MaxiSCR

11

is not communicating properly with the Maxi SCR device and therefore cannot

enter the vehicle control module. In this case, the following checks or measures

are required:

 

Check whether the MaxiSCR device is powered on.

 

When using a wireless connection, check whether the network configuration is

correct or whether the paired devices are correct.

 

If communication is interrupted suddenly due to signal loss during the diagnosis,

check whether there is any object causing signal interference.

 

Check whether the MaxiSCR equipment is placed correctly. Place the MaxiSCR

device face up.

 

Try to get as close to MaxiSCR equipment as possible to get more stable signal

and faster communication speed.

 

When using a wired connection, check whether the cable connection between

the tablet diagnostic device and the MaxiSCR device is good.

Check whether the Bluetooth or USB indicator on the MaxiSCR device is lit.

Check whether the fault indicator on the MaxiSCR device is lit. If the fault

indicator is lit, there may be a communication error between the devices.

At this time, you can try to re

establish the connection; if this method is

invalid, it may indicate that the device hardware is faulty. In this case, you

need to contact technical support

B: If the MaxiSCR device cannot establish normal communication, a prompt message will

appear on the screen and provide the corresponding inspection instructions. The

possible causes of this problem are as follows:

 

The MaxiSCR device cannot establish a communication connection with the

vehicle.

Содержание MaxiSys SCR

Страница 1: ...ons in this manual are based on the latest information available at the time of printing Autel reserves the right to make changes at any time without notice While information of this manual has been carefully checked for accuracy no guarantee is given for the completeness and correctness of the contents including but not limited to the product specifications functions and illustrations Autel will ...

Страница 2: ...d It is crucial to use proper service methods and test procedures It is essential to perform tests in an appropriate and acceptable manner that does not endanger your safety the safety of others in the work area the device being used or the vehicle being tested Before using the device always refer to and follow the safety messages and applicable test procedures provided by the manufacturer of the ...

Страница 3: ...ssages herein cover situations Autel is aware of Autel cannot know evaluate or advise you as to all of the possible hazards You must be certain that any condition or service procedure encountered does not jeopardize your personal safety ...

Страница 4: ...ignition coil distributor cap ignition wires and spark plugs These components create hazardous voltages when the engine is running Keep a fire extinguisher suitable for gasoline chemical and electrical fires nearby Do not connect or disconnect any test equipment while the ignition is on or the engine is running Keep the test equipment dry clean free from oil water or grease Use a mild detergent on...

Страница 5: ...7 List 1 product description 8 1 1 Maxi SCR Urea Pump Tester 8 2 SCR Diagnostic operation 10 3 Regulatory compliance information 错误 未定义书签 ...

Страница 6: ...ntelligent diagnosis solution Convenient fast and efficient intelligent diagnosis of urea pumps nitrogen and oxygen sensors temperature and liquid level sensors on and off the vehicle 1 1 Maxi SCR Urea Pump Tester Function Description Fig 2 1 VCI SCR illustration 1 Power input 2 USB Type A 3 DB15 socket 4 DB44 socket ...

Страница 7: ...tion Power The device can be powered by AC DC adapter 12V 36V Technical Specification Item Description Rating 12V 36V Interface USB typeB Power adapter socket DB44 DB15 Connection USB2 0 2 4G blue tootch Operation 10 50 Storage 20 60 Size 220 4x142 6x40mm Weight 600g ...

Страница 8: ... pump test harness is connected to the urea pump diagnostic interface and connect to the MaxiSCR device power supply 3 Turn on the MaxiSys tablet diagnostic device Make sure that the tablet s built in battery has sufficient power or DC power is connected 4 Establish the communication between MaxiSys tablet diagnostic equipment and MaxiSCR device equipment through Bluetooth pairing 5 After the Maxi...

Страница 9: ...al and faster communication speed When using a wired connection check whether the cable connection between the tablet diagnostic device and the MaxiSCR device is good Check whether the Bluetooth or USB indicator on the MaxiSCR device is lit Check whether the fault indicator on the MaxiSCR device is lit If the fault indicator is lit there may be a communication error between the devices At this tim...

Страница 10: ...ion is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Cet appareil est conforme aux CNR exempts de licence d Industrie Canada Son fonctionnement est soumis aux deux conditions suivantes 1 Ce dispositif ne peut causer des interferences et 2 Ce dispo...

Страница 11: ...tion If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit d...

Страница 12: ...n the radiator your body RoHS COMPLIANCE This device is declared to be in compliance with the European RoHS Directive 2011 65 EU CE COMPLIANCE This product is declared to conform to the essential requirements of the following Directives and carries the CE mark accordingly EMC Directive 2014 30 EU RED Directive 2014 53 EU ...

Отзывы: