Operating manual Sina / Sina Xtra
EN
5 | Technical data
15
5
Specification in mg/m³ for heated filter method (in compliance with Annexe III, number 4, letter a,
section i, point 1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4,
letter a, section i, point 2 and 3.)
6
Specification mg/m³ for heated filter method (in compliance with Annexe III, number 4, letter a, sec-
tion i, point 1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let-
ter a, section i, point 2 and 3.)
7
Specifications are made here for the preferred fuel only.
5.2
General specifications
Technical data
Basic appliance
with HMS/Xtra
Height [mm]
1247
1247
Width [mm]
600
600/725
Depth [mm]
445
445
Weight [kg]
137
205/324
Flue pipe outlet, diameter [mm]
130
130
Nominal heat efficiency [kW] as per EN test EN 13240
6.0
Heat output, minimum [kW]
3.0
Maximum heat output [kW]
8.0
Space heating capacity, at least (depending on the building insula-
tion) [m³]
65
Maximum room-heating capacity (depending on the building insula-
tion) [m³]
165
Minimum distance from non-flammable materials [mm]
50
Safety distances to combustible materials a, b, c [mm]
1000 / 250 / 150
5.3
Data for the chimney/flue dimensioning
Exhaust gas values for the multiple occupancy of the chimney (according to DIN 4705 Part 3) or rating of the
chimney (according to DIN 4705 Part 2)
Flue gas mass flow [g/s]
4.4
Flue gas temperature [°C]
271
Minimum feed pressure at nominal heat output [Pa] closed
12
at 0.8 times nominal heat output [Pa]
10