7 | Requirements at the installation location
EN
Operating manual Pallas Back
18
7.4
Floor load-bearing capacity
Before installing, verify whether the load-bearing capacity of the substructure can withstand the weight
of your Austroflamm stove.
7.5
Floor condition
In the radiation area of the pane (in front of the stove), the floor must not be combustible.
7.6
Room of installation
Note that the room in which the stove is installed must have at least one door / one window leading to
the outside, or be directly connected to such a room. For balanced flue operation, other heating appli-
ances and extractor hoods must not be operated together with this heating appliance as part of the
room air system.