Austroflamm Integra II Скачать руководство пользователя страница 1

M A N U A L

I NTEG R A II

E N G L I S H

Freestanding

Insert

Содержание Integra II

Страница 1: ...M A N U A L INTEGRA II E N G L I S H Freestanding Insert...

Страница 2: ...INSTRUCTIONS FEATURES MAINTENANCE CLEANING QUALITY WARRANTY 2 SAFETY NOTICE IF THIS WOOD PELLET STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW THE INSTALLATION DIRECTIO...

Страница 3: ...ndustry 3 Rika before your purchase please RIKA was founded over 50 years ago in Micheldorf Austria by Karl Riener and his family We appreciate quality and feel that our company manufac turers some of...

Страница 4: ...led correctly BURN WOOD PELLET FUEL ONLY NEVER BURN ANY OTHER FUEL SUCH AS PAPER SOLID WOOD OR CHARCOAL WARNING When operated properly the stove cannot be over fired However continuous operation at ma...

Страница 5: ...while in use as sur faces are hot and may cause burns Never let unsupervised children around stove while in use as children may contact hot stove surfaces which may cause burns Do not cook food hot be...

Страница 6: ...OMNI SAMPLE LABEL FOR AUSTROFLAMM INTEGRA II Insert 6...

Страница 7: ...7 OMNI SAMPLE LABEL FOR AUSTROFLAMM INTEGRA II Insert...

Страница 8: ...Network 230VAC 50Hz II RG fan III Cross flow fan IV Ignition element V Auger motor VI Circulating pump VII Reserve MAIN CONTROL BOARD 1 2 3 4 5 6 7 8 9 VII VI V IV III II I yellow green blue brown PE...

Страница 9: ...Ceramic Side Glass 2 Ceramic Front Glass 3 Cast Iron Door 4 Door Handle Bolt 5 Door Handle 6 Auger Cover 7 Heat Shield 8 Rear Heat Exchanger Access Plate 9 Auger 10 Auger End Plate 11 Auger Motor 12 R...

Страница 10: ...23 Upper Cast Wall 24 High Limit switch 25 Adjustable Door Latch 27 Main Circuit Board 28 Tele Control Europe Only Parts Descriptions 29 40 Fiqure 4 29 Power Cord 30 Flue Adapter 31 Connecting Band 32...

Страница 11: ...6 1 1 2 25 3 4 27 1 4 13 3 4 2 1 4 7 1 2 28 1 2 Specification Capacity 11 37 1 2 25 3 4 Exhaust Outlet Hopper Power 28 1 2 Front Front Total Rear Height Rear Depth into Fireplace Rear Width 19 3 4 27...

Страница 12: ...heats an excess temperature switch Hi Limit will shut off the stove fuel feed After the stove has cooled down the stove defaults back to the original control program However heating only continues if...

Страница 13: ...epartment Improper handling of these parts leads to the warranty becoming null and void ATTENTION Only work on the fire when the mains plug has been removed from the socket Your furnace must be switch...

Страница 14: ...iving area in the house The air taken from the living area must be reintro duced In modern homes very tight fitting windows and doors mean too little air flows into the house for proper combustion Thi...

Страница 15: ...INSTALLATION INTEGRA II INSERT 15...

Страница 16: ...16 INSTALLATION INTEGRA II INSERT Below 2 500 ft altitude a three inch or four inch diameter is appropriate...

Страница 17: ...17 A NEW HEATING PHILOSOPHY...

Страница 18: ...18 WHAT ARE PELLETS association of the Pellet Fuel Institute...

Страница 19: ...19 Pellet Fuel Institute 1601 N Kent Street Suite 1001 Arlington VA 22209 Phone 703 522 6778 cause...

Страница 20: ...ard may only be altered by trained speci alist dealers or the service department Improper handling of these parts leads to the guarantee and warranty becoming null and void MENU key MINUS key ON OFF k...

Страница 21: ...ove needs to be turned off push on off button and stove will go through shut down mode When SB appears in digital readout shut down is complete Time Mode In TM mode the stove can be set to come on at...

Страница 22: ...6 The display now reads CL cleaning cycle and 60 under the CL Once each hour the stove will ramp up to the heat setting for 1 minutes to clean out the burn pot After which it will return to its origin...

Страница 23: ...emoving the pan the area underneath can be vacu umed free daily HEAT EXCHANGER Two pusher rods are located directly under the lid ceramic these are used for clea ning the heat exchanger remove lid To...

Страница 24: ...first and quenched with water Please TAKE CARE Embers can be hidden in the ash only fill into metal containers Vacuuming using the RIKA ashbox is recommended to remove the ash 24 MAINTENANCE AND CLEAN...

Страница 25: ...n have a negative effect on the fire performance and represent a safety risk AIR SENSOR The sensor should be maintained and cle aned by an authorised service technician Cleaning should be carried out...

Страница 26: ...low 7 Thermal switch lower temperature limit was triggered possible solutions 1 Fill up pellet container 2 See the following section Pellets not fed in 3 Leave the furnace to cool down for an hour an...

Страница 27: ...s Any repairs may only be carried out by trained personnel Error messages control If the heater stops because it is programm ed to do so e g Pellet container empty excess temperature protection trigge...

Страница 28: ...switched off but active for triggering via Tele control Manual operation Automatic operation Monday to Sunday Heating start times heating end times for automatic mode TM Output value from the beginnin...

Страница 29: ...O USE OF THIS PRODUCT USER S SOLE AND EXCLUSIVE REMEDY FOR ANY NONCONFOR MITY IN THE PRODUCT OR ANY CLAIM RELATED TO THE USE OF THE PRODUCT SHALL BE AT MANUFACTURER S OPTION REPAIR OR REPLACEMENT OF T...

Страница 30: ...delivery of spare parts Working hours and travelling time are not covered by the Manufacturer s Guarantee All costs e g transport repairs etc incur red by the manufacturer due to an unjusti fied Guara...

Страница 31: ...Rev 9 06...

Отзывы: