8.3.1.2
Live View – Expert Mode
The expert mode of Live View provides access to 158 internal ECU signals. To be able to dis-
tinguish between similar sounding signals (i.e. there are 11 signals available concerning the
boost pressure measurement) when talking to supporting experts, each signal in the list also
carries an abbreviated “codename” which can be used to identify the signal in question.
Steps:
1) Connect to ECU
2) Select «Live View» tab
3) Check “Expert Mode”
4) Select sample interval (default = 0.1s)
5) Select up to 52 signals per ECU
- 158 non-standard signals are available
- e.g. raw sensor voltages can be monitored
- individual sensors of redundant sets can be monitored (i.e. power lever adjustment)
- contents of status or error registers
- status of internal state machines
6) Press the Record Live View button
7) … continue as explained in section “8.3.1.1 Live View – Standard Mode”
8.3.1.3
Live View – Aux Signal
This functionality is provided for escalated maintenance situations where remote support by
an Austro Engine expert may require access to auxiliary signals which have no name as-
signed and are not part of the list of 158 signals defined in the AE300-Wizard.
Application of this functionality is outside of the scope of this user guide and is meant to be
used only under the guidance of an Austro Engine design engineer.
8.3.2
Live View – Online Analysis using Pre-Defined Measurements
To help with standard maintenance tasks, 5 pre-defined signal sets have been developed for
the following situations: