Hum Problems

Most equipment is designed for minimum hum when used under ideal condi-
tions. When connected to other equipment, and to a safety earth in an electri-
cally noisy environment, problems may occur. 

The three ”E”s of hum and hum related noise which can plague your audio 
system are:
a) Electrostatic radiation,
b) Electromagnetic radiation, and
c) Earth loops

Electrostatic radiation capacitively couples to system elements, causing an 
interference voltage that mainly affects higher impedance paths, such as 
amplifi er inputs. The source is generally a nearby high voltage, such as a 
mains lead or a speaker lead. The problem can usually be reduced by moving 
the offending lead away, or by providing additional electrostatic shielding (i.e. 
an earthed conductor which forms a barrier to the fi eld).

Electromagnetic radiation induces interference currents into system ele-
ments that mainly effect lower impedance paths.  Radio transmitters or stray 
magnetic fi elds from mains transformers are often the cause of this problem. 
It is generally more diffi cult to eliminate this kind of interference, but again, 
moving the source away or providing a magnetic shield (i.e. a steel shield) 
should help.

Earth loops can arise from the interfacing of the various pieces of equipment 
and their connections to various safety earths.

This is by far the most common cause of hum, and it occurs when source 
equipment and the amplifi er are plugged into different points along the safety 
earth where the safety earth wiring has a current fl owing through it. The cur-
rent fl owing through the wire produces a voltage drop due to the wire’s resist-
ance. This voltage difference between the amp earth and source equipment 
earth appears to the amplifi er’s input as a signal and is amplifi ed as hum.

There are three things you can do to avoid earth loop problems:

Ensure the mains power for the audio system is “quiet” i.e. without equipment 
on it such as air-conditioning, refrigeration or lighting which may generate 
noise in the earth circuit.

Ensure all equipment within the system shares a common ground/ safety 
earth point. This will reduce the possibility of circulating earth currents, as the 
equipment will be referenced to the same ground potential.

Ensure that balanced signal leads connecting to the amplifi er are connected to 
earth at one end only.

Signal Ground-Lift Switch

When proper system hook-up has been made, you may still have some hum 
or hum related noise. This may be due to any of the previously mentioned 
gremlins.

Your Synergy-2 Series amplifi er has a “Signal Ground Lift” switch which dis-
connects the input ground wiring from the amplifi er. A substantial drop in hum 
and/or hum related noise can result from the judicious use of this switch.

 

NOTE: If the input ground lift switch is used, you must ensure 

 

adequate shielding of the input wiring. If the signal source equipment 

 

does not provide adequate shielding (i.e. a defi nitive connection to 

 

ground), you must disconnect the shield from the input connector’s 

 

ground pin (Pin-1) and re-connect it to the ”drain” contact on the input 

 

connector. This will ensure the shield on your input wiring actually 

 

goes to the amplifi er chassis and subsequently to earth.

 

IMPORTANT: Do not connect pin-1 directly to the drain connection.

You will defeat the amplifi ers internal grounding scheme and possibly cause 
instability to the amplifi er.

Always ensure that your amplifi er is off and the attenuators are down when 
you engage this switch. This switch should only be used when the amplifi er is 
operated from a balanced signal source.

 

NOTE: Be wary of quasi-balanced outputs, these are often no more 

 

than fl oating unbalanced outputs.

Содержание SY2200

Страница 1: ...AUDIO AMPL UDIO AMP PROFESSION PROFESSIONAL AUDIO AMPLIFIER SY2200 SY2400 SY2700 OPERATION MANUAL ...

Страница 2: ... normal flow of air around the unit such as a bed rug weathersheet carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign matter 14 Do not remove the cover Removing the cover will expose you to potentially dangerous voltages There are no user serviceable parts inside 15 Do not drive the inputs with a s...

Страница 3: ... control required by your speakers at high duty cycles for extended periods INTRODUCTION 3 FEATURES 4 CONTROLS CONNECTORS AND INDICATORS FRONT PANEL 5 REAR PANEL 6 INSTALLATION 7 OPERATION 9 MAINTENANCE 10 BLOCK DIAGRAM 10 SPECIFICATIONS 11 This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the products enclosure that may be of sufficient magnitude to...

Страница 4: ...lift switch Built in limiter circuit Stereo or bridged operation Binding post and 4 pole speaker output connection 1 Watt output indication 2 828 volts Output clip indication Multi role output fault indication High quality close tolerance components throughout Suppression of inrush current at mains turn on Input muting at turn on Input overvoltage protection Radio frequency interference suppressio...

Страница 5: ...upply rails and alters with changes in the mains supply changes in the load and duty cycle fluctuations The attack and decay time ballistics of the status circuit are those of a Peak Programme Meter P P M If using this indicator to line up sensitivities apply a steady state tone e g slate on a mixing con sole The 1 watt level is the mid point between the indicator illuminating and extinguishing gr...

Страница 6: ...internally connected mains lead SY2700 Please ensure that the connecting mains lead for use with the IEC connector is of an approved type and is of sufficient current carrying ability NOTE Your unit must always be earthed Mains Fuse or Circuit Breaker Either a 20mm x 5mm fuse drawer is provided within the housing of the IEC mains connector SY2200 SY2400 or the amplifier is fitted with a resettable...

Страница 7: ...an unbalanced source you must ensure that pin 3 is connected to pin 1 input ground either by linking the pins in the input con nector or by the source equipment s output wiring When wiring for an unbalanced source Pin 1 GROUND SHIELD Pin 2 HOT in phase with the amplifier s output Pin 3 GROUND SHIELD joins to pin 1 NOTE In line XLR connectors often have a termination lug that connects directly to t...

Страница 8: ...ppears to the amplifier s input as a signal and is amplified as hum There are three things you can do to avoid earth loop problems Ensure the mains power for the audio system is quiet i e without equipment on it such as air conditioning refrigeration or lighting which may generate noise in the earth circuit Ensure all equipment within the system shares a common ground safety earth point This will ...

Страница 9: ... an initialising period before it will accept signal The Inrush Current Suppression ICS circuit is in operation for the first 0 5 seconds This limits the mains cur rent to prevent nuisance tripping of circuit breakers During this period you will hear a couple of relays click indicating mains is now directly applied to the amplifier and the signal path is connected While the ICS circuit operates th...

Страница 10: ...fan blades must be held still whilst blowing air over the blades otherwise you may burn out the bearings in the fan Fuses Along with rear panel mains fuse there are four 4 rail fuses provided internally in the unit These rail fuses are in series with the positive and nega tive output supply to each amplifier channel and provide overall protection for the output stage If the amplifier is subjected ...

Страница 11: ...lt Model SY 2400 Output Power 0 1 THD 1kHz Voltage Gain 37 4 31dB Thermal Dissipation Both channels 2ohm 1 8th power 780W 2661btu hr Current Draw Both channels driven 2ohm load 230Vac 1 8th power 5 0A Dimensions H x W x D 87mm x 482mm x 400mm Shipping Weight 17 Kg Shipping Dimensions H x W x D 210mm x 540mm x 540mm Max Input Power 1830 VA Model SY 2700 Output Power 0 1 THD 1kHz Voltage Gain 52 9 3...

Страница 12: ...8 Email sa audiotelex com au PERTH WA SALES 299 Fitzgerald Street West Perth WA 6005 PO Box 404 North Perth WA 6906 Phone 08 9228 4222 Fax 08 9228 4233 Email wa audiotelex com au AUCKLAND NZ SALES Unit B 11 Piermark Drive Albany 1331 New Zealand PO Box 512 Albany 1331 Phone 09 415 9426 Fax 09 415 9864 Email sales audiotelex co nz AUSTRALIA AND NEW ZEALAND www australianmonitor com au EUROPE ASIA M...

Отзывы: