I N S TA L L AT I O N

PA G E  7

S Y N E R G Y   2   –   O P E R AT I O N   M A N U A L

Power Requirements

Power consumption for your model of the Synergy-2 
Series amplifi er is indicated on the rear panel for 
maximum output.

Ensure that your mains voltage is the same as the 
rear panel mains voltage marker (+/- 10%). 

Mounting

Your amplifi er is designed for standard 19” rack 
mounting and occupies 2 EIA rack units (3.5”). The 
mounting centres are: 

Vertical: 3.0” 

(76.2mm)

Horizontal: 18.2” (461.2mm) to 18.7” (473.8mm). 

The slots in the mounting fl ange will accept bolt 
diameters up to 1/4” (6.35mm).

We recommend that you provide additional support 
for the amplifi er, especially if road use is planned, 
as the weight could bend some rack frames. This 
support can be provided by secure shelving, support 
rails or a rear rack mounting strip to match up with 
the rear rack mount ears provided on your Synergy-2 
Series amplifi er.

Cooling

Each channel of your Synergy-2 Series amplifi er is 
cooled by an axial fan which draws cool air from the 
front of the amplifi er and expels the heated air out 
the rear of the amplifi er. These amplifi ers offer two 
speed fans which run at half speed, switching to 
full speed when the internal heatsink temperature 
exceeds 600 C (1280 F).

An unrestricted airfl ow into and out from the ampli-
fi er must be provided. Any restriction of the air fl ow 
will cause heat to build up within the unit and pos-
sibly force the unit into its thermal shutdown mode.

If the amplifi ers are to be operated in an 
environment where the airfl ow is restricted such as 
sealed racks, the cooling should be supplemented 
by extra cooling fans to evacuate the heated air and 
aid the fl ow of cool air through the unit.

Input Wiring

 
 

IMPORTANT:  Do not directly connect pin 

 

1 on the amplifi er’s input  or strapping XLR,

 

to the amplifi er’s chassis, speaker ground or 

 power 

ground!

 

WARNING: Input signal ground is not to 

 

be used as a safety ground (earth).

The input to your amplifi er is a balanced 3-pin 
confi guration and requires all three pins to be 
connected. Only high quality twin-core shielded 
cable should be used. 

When wiring for a balanced source, the connector 
going to the input of your amplifi er should be wired 
as follows:
Pin 1 = GROUND / SHIELD.
Pin 2 = HOT (In Phase - non inverting).
Pin 3 = COLD (Reverse Phase - inverting).

When wiring from an unbalanced source you 
must ensure that pin 3 is connected to pin 1 (input 
ground), either by linking the pins in the input con-
nector or by the source equipment’s output wiring.

When wiring for an unbalanced source:
Pin 1 = GROUND/SHIELD
Pin 2 = HOT (in phase with the amplifi er’s output),
Pin 3 = GROUND/SHIELD (joins to pin 1).

 

NOTE: In-line XLR connectors often have a 

 

termination lug that connects directly to the 

 

chassis of the connector. 

 

IMPORTANT:  Do not link this lug to 

 

pin 1 at the amplifi er’s input as it will defeat 

 

the amplifi er’s input grounding scheme. 

Output Wiring

When wiring to your speakers always use the 
largest gauge wire your connector will accept. The 
longer the speaker lead, the greater the losses will 
be, resulting in reduced power and less damping at 
the load. We recommend using a heavy duty, two 
core fl ex (four core fl ex if bi-amping) 10 to 12 gauge 
(2mm2 to 2.5mm2 or 50/0.25 or equivalent) as a 
minimum.

Binding Post Outputs

When terminating to the 4 mm binding post (banana 
jack) output connectors, banana plugs or bare wires 
can be used. The red terminal is positive and the 
black terminal is negative (ground). 

If running in BRIDGE mode, only the red binding 
posts are used.

When bridging, Channel A provides the positive 
output to the load and channel B provides the 
negative output to the load. 

Speaker Outputs

When using the 4 pole speaker connector for 
speaker output, use only the mating 4 pole in-line 
connector. This connector is designed so that both 
channels can be fed from a single connector.

Two speaker connectors are provided on the 
amplifi er.

The ”Channel A” speaker connector actually carries 
both channel A & channel B outputs (see Figure 6: 
Speaker Connector Wiring Diagrams). 

The ”Channel B” speaker connector carries the 
Channel B output only. 

This arrangement allows you the option of connect-
ing to the outputs separately or together. Connect-
ing through a single connector has the advantage 
of minimising connections, preserving phasing and 
simplifying channel allocation, which is particularly 
important when bi-amping or in bridge mode. 

 

IMPORTANT:  Do not overload your amplifi er 

 

by connecting the channel B output twice!

Channel A is used as the “dominant” channel 
and when sourcing a dual output from Channel A, 
the following standard should normally be used 
(depending on speaker system wiring):
Channel A = Left or Low Frequencies.
Channel B = Right or High Frequencies.

When in bridge mode:
Pin 1+ = Bridge Output Positive
Pin 2+ = Bridge Output Negative.

Содержание SY2200

Страница 1: ...AUDIO AMPL UDIO AMP PROFESSION PROFESSIONAL AUDIO AMPLIFIER SY2200 SY2400 SY2700 OPERATION MANUAL ...

Страница 2: ... normal flow of air around the unit such as a bed rug weathersheet carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign matter 14 Do not remove the cover Removing the cover will expose you to potentially dangerous voltages There are no user serviceable parts inside 15 Do not drive the inputs with a s...

Страница 3: ... control required by your speakers at high duty cycles for extended periods INTRODUCTION 3 FEATURES 4 CONTROLS CONNECTORS AND INDICATORS FRONT PANEL 5 REAR PANEL 6 INSTALLATION 7 OPERATION 9 MAINTENANCE 10 BLOCK DIAGRAM 10 SPECIFICATIONS 11 This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the products enclosure that may be of sufficient magnitude to...

Страница 4: ...lift switch Built in limiter circuit Stereo or bridged operation Binding post and 4 pole speaker output connection 1 Watt output indication 2 828 volts Output clip indication Multi role output fault indication High quality close tolerance components throughout Suppression of inrush current at mains turn on Input muting at turn on Input overvoltage protection Radio frequency interference suppressio...

Страница 5: ...upply rails and alters with changes in the mains supply changes in the load and duty cycle fluctuations The attack and decay time ballistics of the status circuit are those of a Peak Programme Meter P P M If using this indicator to line up sensitivities apply a steady state tone e g slate on a mixing con sole The 1 watt level is the mid point between the indicator illuminating and extinguishing gr...

Страница 6: ...internally connected mains lead SY2700 Please ensure that the connecting mains lead for use with the IEC connector is of an approved type and is of sufficient current carrying ability NOTE Your unit must always be earthed Mains Fuse or Circuit Breaker Either a 20mm x 5mm fuse drawer is provided within the housing of the IEC mains connector SY2200 SY2400 or the amplifier is fitted with a resettable...

Страница 7: ...an unbalanced source you must ensure that pin 3 is connected to pin 1 input ground either by linking the pins in the input con nector or by the source equipment s output wiring When wiring for an unbalanced source Pin 1 GROUND SHIELD Pin 2 HOT in phase with the amplifier s output Pin 3 GROUND SHIELD joins to pin 1 NOTE In line XLR connectors often have a termination lug that connects directly to t...

Страница 8: ...ppears to the amplifier s input as a signal and is amplified as hum There are three things you can do to avoid earth loop problems Ensure the mains power for the audio system is quiet i e without equipment on it such as air conditioning refrigeration or lighting which may generate noise in the earth circuit Ensure all equipment within the system shares a common ground safety earth point This will ...

Страница 9: ... an initialising period before it will accept signal The Inrush Current Suppression ICS circuit is in operation for the first 0 5 seconds This limits the mains cur rent to prevent nuisance tripping of circuit breakers During this period you will hear a couple of relays click indicating mains is now directly applied to the amplifier and the signal path is connected While the ICS circuit operates th...

Страница 10: ...fan blades must be held still whilst blowing air over the blades otherwise you may burn out the bearings in the fan Fuses Along with rear panel mains fuse there are four 4 rail fuses provided internally in the unit These rail fuses are in series with the positive and nega tive output supply to each amplifier channel and provide overall protection for the output stage If the amplifier is subjected ...

Страница 11: ...lt Model SY 2400 Output Power 0 1 THD 1kHz Voltage Gain 37 4 31dB Thermal Dissipation Both channels 2ohm 1 8th power 780W 2661btu hr Current Draw Both channels driven 2ohm load 230Vac 1 8th power 5 0A Dimensions H x W x D 87mm x 482mm x 400mm Shipping Weight 17 Kg Shipping Dimensions H x W x D 210mm x 540mm x 540mm Max Input Power 1830 VA Model SY 2700 Output Power 0 1 THD 1kHz Voltage Gain 52 9 3...

Страница 12: ...8 Email sa audiotelex com au PERTH WA SALES 299 Fitzgerald Street West Perth WA 6005 PO Box 404 North Perth WA 6906 Phone 08 9228 4222 Fax 08 9228 4233 Email wa audiotelex com au AUCKLAND NZ SALES Unit B 11 Piermark Drive Albany 1331 New Zealand PO Box 512 Albany 1331 Phone 09 415 9426 Fax 09 415 9864 Email sales audiotelex co nz AUSTRALIA AND NEW ZEALAND www australianmonitor com au EUROPE ASIA M...