AUSTRALIAN MONITOR SY2200 Скачать руководство пользователя страница 11

S P E C I F I C AT I O N S

PA G E   1 1

S Y N E R G Y   2   –   O P E R AT I O N   M A N U A L

Model: SY 2200

Output Power

  

0.1% THD @ 1kHz

Voltage Gain

 28.3 

(29dB)

Thermal Dissipation

Both channels driven, 2ohm load

1/8th power 

425W (1450btu/hr)

Current Draw

Both channels driven, 2ohm load, 230Vac

1/8th power 

2.7A

Dimensions (H x W x D)

  

87mm x 482mm x 400mm

Shipping Weight 

 14 

Kg

Shipping Dimensions (H x W x D)

  

210mm x 540mm x 540mm

Max Input Power

 1000 

VA

Common Specifi cations (To all SY2 Amplifi ers)

Distortion 

(re 4ohm, 1dB below clip)

THD (@ 1kHz) 

 

 

<0.02%

IMD SMPTE (60Hz : 7kHz 4:1) 

 

<0.03%

Input Impedance

  

20kohms

Input Sensitivity

  

1Vrms

Input CMRR

  

 

>80dB

Signal/Noise Ratio

A-Weighted  

 

>104dB

Crosstalk

  

 

>70dB

Slew rate

  

 

>40 

V/µsec

Damping factor

 (@ 1kH re 8 ohms) 

 

> 375:1

Frequency response

 (+/-3dB) 

 

15 Hz- 50 kHz

Indicators

 

 Power, Status/Clip (L/R), Overload, Thermal, Fault

Model: SY 2400

Output Power

  

0.1% THD @ 1kHz

Voltage Gain

 37.4 

(31dB)

Thermal Dissipation

Both channels, 2ohm

1/8th power 

780W (2661btu/hr)

Current Draw

Both channels driven, 2ohm load, 230Vac

1/8th power 

5.0A

Dimensions (H x W x D)

  

87mm x 482mm x 400mm

Shipping Weight

  

17 Kg

Shipping Dimensions (H x W x D)

  

210mm x 540mm x 540mm

Max Input Power

 1830 

VA 

Model: SY 2700

Output Power

  

0.1% THD @ 1kHz

Voltage Gain

 52.9 

(34dB)

Thermal Dissipation

Both channels driven, 2ohm load

1/8th power 

1410W (4811btu/hr)

Current Draw

Both channels driven, 2ohm load, 230Vac

1/8th power 

9.1A

Dimensions (H x W x D)

 

210mm x 540mm x 575mm

Shipping Weight

 19 

Kg

Shipping Dimensions

 

(H x W x D)

  

210mm x 540mm x 575mm

Max Input Power

 3400 

VA

 2ohm 

 2ohm 

4ohm 

8ohm

 

single channel 

both channels driven

Stereo 345 

300 

200  110

Bridged  

 

600  400

 2ohm 

 2ohm 

4ohm 

8ohm

 

single channel 

both channels driven

Stereo 1150 

1000 

700  40

Bridged  

 

2000 1400

 2ohm 

 2ohm 

4ohm 

8ohm

 

single channel 

both channels driven

Stereo 600 

525 

350  190

Bridged  

 

1100 700

Содержание SY2200

Страница 1: ...AUDIO AMPL UDIO AMP PROFESSION PROFESSIONAL AUDIO AMPLIFIER SY2200 SY2400 SY2700 OPERATION MANUAL ...

Страница 2: ... normal flow of air around the unit such as a bed rug weathersheet carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign matter 14 Do not remove the cover Removing the cover will expose you to potentially dangerous voltages There are no user serviceable parts inside 15 Do not drive the inputs with a s...

Страница 3: ... control required by your speakers at high duty cycles for extended periods INTRODUCTION 3 FEATURES 4 CONTROLS CONNECTORS AND INDICATORS FRONT PANEL 5 REAR PANEL 6 INSTALLATION 7 OPERATION 9 MAINTENANCE 10 BLOCK DIAGRAM 10 SPECIFICATIONS 11 This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the products enclosure that may be of sufficient magnitude to...

Страница 4: ...lift switch Built in limiter circuit Stereo or bridged operation Binding post and 4 pole speaker output connection 1 Watt output indication 2 828 volts Output clip indication Multi role output fault indication High quality close tolerance components throughout Suppression of inrush current at mains turn on Input muting at turn on Input overvoltage protection Radio frequency interference suppressio...

Страница 5: ...upply rails and alters with changes in the mains supply changes in the load and duty cycle fluctuations The attack and decay time ballistics of the status circuit are those of a Peak Programme Meter P P M If using this indicator to line up sensitivities apply a steady state tone e g slate on a mixing con sole The 1 watt level is the mid point between the indicator illuminating and extinguishing gr...

Страница 6: ...internally connected mains lead SY2700 Please ensure that the connecting mains lead for use with the IEC connector is of an approved type and is of sufficient current carrying ability NOTE Your unit must always be earthed Mains Fuse or Circuit Breaker Either a 20mm x 5mm fuse drawer is provided within the housing of the IEC mains connector SY2200 SY2400 or the amplifier is fitted with a resettable...

Страница 7: ...an unbalanced source you must ensure that pin 3 is connected to pin 1 input ground either by linking the pins in the input con nector or by the source equipment s output wiring When wiring for an unbalanced source Pin 1 GROUND SHIELD Pin 2 HOT in phase with the amplifier s output Pin 3 GROUND SHIELD joins to pin 1 NOTE In line XLR connectors often have a termination lug that connects directly to t...

Страница 8: ...ppears to the amplifier s input as a signal and is amplified as hum There are three things you can do to avoid earth loop problems Ensure the mains power for the audio system is quiet i e without equipment on it such as air conditioning refrigeration or lighting which may generate noise in the earth circuit Ensure all equipment within the system shares a common ground safety earth point This will ...

Страница 9: ... an initialising period before it will accept signal The Inrush Current Suppression ICS circuit is in operation for the first 0 5 seconds This limits the mains cur rent to prevent nuisance tripping of circuit breakers During this period you will hear a couple of relays click indicating mains is now directly applied to the amplifier and the signal path is connected While the ICS circuit operates th...

Страница 10: ...fan blades must be held still whilst blowing air over the blades otherwise you may burn out the bearings in the fan Fuses Along with rear panel mains fuse there are four 4 rail fuses provided internally in the unit These rail fuses are in series with the positive and nega tive output supply to each amplifier channel and provide overall protection for the output stage If the amplifier is subjected ...

Страница 11: ...lt Model SY 2400 Output Power 0 1 THD 1kHz Voltage Gain 37 4 31dB Thermal Dissipation Both channels 2ohm 1 8th power 780W 2661btu hr Current Draw Both channels driven 2ohm load 230Vac 1 8th power 5 0A Dimensions H x W x D 87mm x 482mm x 400mm Shipping Weight 17 Kg Shipping Dimensions H x W x D 210mm x 540mm x 540mm Max Input Power 1830 VA Model SY 2700 Output Power 0 1 THD 1kHz Voltage Gain 52 9 3...

Страница 12: ...8 Email sa audiotelex com au PERTH WA SALES 299 Fitzgerald Street West Perth WA 6005 PO Box 404 North Perth WA 6906 Phone 08 9228 4222 Fax 08 9228 4233 Email wa audiotelex com au AUCKLAND NZ SALES Unit B 11 Piermark Drive Albany 1331 New Zealand PO Box 512 Albany 1331 Phone 09 415 9426 Fax 09 415 9864 Email sales audiotelex co nz AUSTRALIA AND NEW ZEALAND www australianmonitor com au EUROPE ASIA M...