PAGE 25
HSP SERIES INSTALLATION AND OPERATION MANUAL
section
gr
oup
param
sub
ssub
V
alue T
ype
V
alue Range
Description
Comment
Operation Per
mission:
N
o access |
U
nsecur
e
S
ecur
e |
A
dmin
set
get
leveli
signed 8-bit number
-128dB..127dB
Level in meter status
N
S
levelo
signed 8-bit number
-128dB..127dB
Level out meter status
N
S
mixoutXinY
object
Mixer config for Output X Input
Y wher
e X = 1..numoutput, Y =
1..numinput
-
-
idout
unsigned 8-bit number
1..numoutput
Output ID index
N
S
idin
unsigned 8-bit number
1..numinput
Input ID index
N
S
source
bool
true/false
Source select
Input source selection for Output
(single Input selection,
no
mixing)
S
S
outX
object
Config for Output X wher
e X =
1..numoutput
-
-
id
unsigned 8-bit number
1..numoutput
Output ID index
N
S
name
string
32 bytes,
UTF-8
Output name
No space or comma in name
S
S
invert
bool
true/false
Invert enable flag
S
S
mute
bool
true/false
Mute enable flag
S
S
extmute
bool
true/false
External Mute Control enable flag
Enable/disable external mute
control for this output
S
S
vol
float (32-bit) number
-128.0dB..127.0dB
Volume
S
S
up
float (32-bit) number
0.0dB..127.0dB
Increase volume by specified value
S
N
down
float (32-bit) number
0.0dB..127.0dB
Decrease volume by specified value
S
N
status
object
Input Status information
-
-
levelo
signed 8-bit number
-128dB..127dB
Level out meter status
N
S
filterX
object
Filter X where X = 1..numfilterout
-
-
id
unsigned 8-bit number
1..numfilter
Filter ID index
N
S
enable
bool
true/false
Enable flag
S
S
type
string
hp,
lp
Filter type:
hi-pass,
all-pass
Two byte string
S
S
freq
unsigned 16-bit number
1Hz..20kHz
Cut-off frequency
S
S
gain
float (32-bit) number
-128.0dB..30.0dB
Gain (cut / boost)
S
S
family
char
b, s
, l
Filter family:
butterworth,
bessel,
linkwitz–riley
S
S
SERIAL COMMAND PROTOCOL (CONT)