PAGE 14
HSP SERIES INSTALLATION AND OPERATION MANUAL
INSTALLATION (CONT)
Speaker Outputs
The amplifier output has a 6 pin output screw terminal with a pre-fitted link between the 4Ohm and the high impedance output.
70V
•
Fit the link between 4Ω and the OT-IN. (This connects the amplifier output to the input of the 70/100V transformer)
•
Connect your speaker to the HIGH IMPEDANCE OUTPUT ‘C’ and ‘70V’ connections
100V
•
Fit the link between 4Ω and the OT-IN. (This connects the amplifier output to the input of the 70/100V transformer)
•
Connect your speaker to the HIGH IMPEDANCE OUTPUT ‘C’ and ‘100V’ connections
4Ω or 8Ω operation
•
Remove the link between 4Ω and the OT-IN
•
Connect your speaker to the LOW IMPEDANCE OUTPUT ‘C’ and ‘4Ω’ connections
4/8 Ohm
70V
100V
OUTPUT CONFIGURATION FOR ALL CHANNELS
LOW IMPEDANCE
OUTPUT
Connect the Link for
70V/100V Output Operation
HIGH IMPEDANCE
OUTPUT
LINK
70V
LINK
100V