IMPORTANT SAFETY INFORMATION

1.  Save the carton and packing material even if the equipment has  
 

arrived in good condition. Should you ever need to ship the unit, use 

 

only the original factory packing.

2.  Read all documentation before operating your equipment. Retain  
 

all documentation for future reference.

3.  Follow all instructions printed on unit chassis for proper operation.

4.  Do not spill water or other liquids into or on the unit, or operate  
 

the unit while standing in liquid.

5.  Make sure power outlets conform to the power requirements listed  
 

on the back of the unit.

6.  Do not use the unit if the electrical power cord is frayed or broken. 
 

The power supply cords should be routed so that they are not likely  

 

to be walked on or pinched by items placed upon or against them,  

 

paying particular attention to cords and plugs, convenience  

 

receptacles, and the point where they exit from the appliance.

7.  Always operate the unit with the AC ground wire connected to the 
 

electrical system ground. Precautions should be taken so that the 

 

means of grounding of a piece of equipment is not defeated.

8.  Mains voltage must be correct and the same as that printed on the 
 

rear of the unit. Damage caused by connection to improper AC voltage 

 

is not covered by any warranty.

9.  Have gain controls on amplifiers turned down during power-up  
 

to prevent speaker damage if there are high signal levels at the inputs.

10  Power down & disconnect units from mains voltage before making 
 

connections.

11.  Never hold a power switch in the “ON” position if it won’t stay  
 

there itself!

12.  Do not use the unit near stoves, heat registers, radiators, or other heat 
 

producing devices.

13.  Do not block fan intake or exhaust ports. Do not operate equipment  
 

on a surface or in an environment which may impede the normal flow 

 

of air around the unit, such as a bed, rug, weathersheet, carpet,  

 

or completely enclosed rack. If the unit is used in an extremely dusty 

 

or smoky environment, the unit should be periodically “blown free”  

 

of foreign matter.

14.  Do not remove the cover. Removing the cover will expose you  
 

to potentially dangerous voltages. There are no user serviceable  

 

parts inside.

15.  Do not drive the inputs with a signal level greater than that required  
 

to drive equipment to full output.

16.  Do not connect the inputs / outputs of amplifiers or consoles to any 
 

other voltage source, such as a battery, mains source, or power supply, 

 

regardless of whether the amplifier or console is turned on or off.

17.  Do not run the output of any amplifier channel back into another  
 

channel’s input. Do not parallel- or series-connect an amplifier output 

 

with any other amplifier output. Australian Monitor Inc is not  

 

responsible for damage to loudspeakers for any reason.

18.  Do not ground any red (“hot”) terminal. Never connect a “hot” (red) 
 

output to ground or to another “hot” (red) output!

19.  Non-use periods. The power cord of equipment should be unplugged 
 

from the outlet when left unused for a long period of time.

20.  Service Information Equipment should be serviced by qualified service 
 

personnel when:

A.  The power supply cord or the plug has been damaged.

B.  Objects have fallen, or liquid has been spilled into the equipment

C. The equipment has been exposed to rain

D. The equipment does not appear to operate normally, or exhibits a marked 
 

change in performance

E. The equipment has been dropped, or the enclosure damaged.

THIS SAFETY INFORMATION IS OF A GENERAL NATURE AND MAY BE SUPERSEDED BY INSTRUCTIONS CONTAINED WITHIN THIS MANUAL

Содержание HA6

Страница 1: ...HA6 6 CHANNEL STEREO HEADPHONE AMPLIFIER INSTALLATION AND OPERATION MANUAL ...

Страница 2: ...ng devices 13 Do not block fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug weathersheet carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign matter 14 Do not remove the cover Removing the ...

Страница 3: ...ucts enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons This symbol is intended to alert the user to the presence of important operational and maintenance servicing instructions in the literature accompanying the appliance To prevent electric shock do not use this polarised plug with an extension cord receptacle or other outlet unless the blades can be ...

Страница 4: ...s on the tip and right is on the sleeve VOLTAGE SELECT SWITCH This switch is used to select the mains voltage for your region WARNING Check that this switch is in the correct position for your region before turning on the device Operating this equipment with the wrong setting may result in damage to the unit IMPORTANT Disconnect power to the amplifier before operating this switch IEC MAINS INPUT S...

Страница 5: ... over driven Reduce output volume No sound but amp is on Volume turned down Check volume controls INSTALLATION TROUBLESHOOTING PAGE 5 AMIS HA6 INSTALLATION OPERATION MANUAL INPUT CONNECTIONS For wiring balanced in pin 2 is hot Balanced input wiring shielded pair cable is recommended Unbalanced RCA wiring should be keep as short as possible Typically less than 3m ...

Страница 6: ...PAGE 6 DIMENSIONS AMIS HA6 INSTALLATION OPERATION MANUAL ...

Страница 7: ...dBu Imp 10k Max Level in XLR mic 9dBu line 30dBu RCA 30dBu TRS 30dBu Max Level out 21dBu Outputs Nominal Level 0dBu into 1kohm Imp 100ohm Power Input AC 230V 50Hz or 115V 60Hz 3 pin IEC320 C14 connector Power Consumption max 7 5VA Fuses Mains 115V 125mA MAins 230V 63mA Dimensions H x W x D 44mm x 482mm x 182mm 1 75 x19 x7 2 Shipping Dimensions 90mm x 505mm x 270mm 3 5 x19 9 x10 6 Weight Net 2 8kg ...

Страница 8: ... 31 Walsh Street Thebarton SA 5031 PO Box 157 Hindmarsh SA 5007 Phone 08 8352 4444 Fax 08 8352 4488 Email sa audiotelex com au PERTH WA SALES 3 11 Howe Street Osborne Park WA 6017 PO Box 1281 Osborne Park BC WA 6916 Phone 08 9228 4222 Fax 08 9228 4233 Email wa audiotelex com au AUCKLAND NZ SALES 9C Piermark Drive Albany 0752 New Zealand PO Box 300 512 Albany 0752 Phone 09 415 9426 Fax 09 415 9864 ...