AUSTRALIAN MONITOR ES120P Скачать руководство пользователя страница 7

ESP SERIES

 INSTALLATION AND OPERATION MANUAL

7

POWER REQUIREMENTS

Power consumption for your model of the ESP Series amplifier is indicated on the rear panel for 1/8th output power.

Ensure that your mains voltage is the same as the rear panel mains voltage marker (

±

10%).

MOUNTING

The ESP Series amplifiers are two rack units high (2U) and will fit a standard EIA 19” or rack.

Typically amplifiers may be stacked directly on top of each other with no need for spacing between units, unless installed in high 

ambient temperature environments where a single rack unit space between amplifiers will assist cooling further.

COOLING

The power amplifiers are cooled by axial fans which draw air inside the amplifier and expel the heated air outside the amplifier.

An unrestricted airflow into and out from the amplifier must be provided. Any restriction of the air flow will cause heat to build up within

the unit and possibly force the unit into its thermal shutdown mode.

If the amplifiers are to be operated in an environment where the airflow is restricted such as sealed racks, cooling should be

supplemented by extra cooling fans to evacuate the heated air and aid the flow of cool air through the unit.

OUTPUT WIRING

When wiring to your speakers always use the largest gauge wire your connector will accept. The longer the speaker lead the greater 

the losses which will result in reduced power and less damping at the load. We recommend using a heavy duty, two core flex (four core 

flex if bi-amping) 10 to 12 gauge (2mm2 to 2.5mm2 or 50/0.25 or equivalent) as a minimum.

SPEAKER OUTPUT

The output terminal strip accepts wire sizes from 16-22AWG 

(1.5mm2 – 0.35mm2) or spade lugs. 

The following table should be used as a guideline for cable 

sizes. Regulations in your area may require different gauged

wire and should be checked before using.

INSTALLATION

OUTPUT DISTANCE

ES120P

ES250P

ES500P

100V

Upto 50m

AWG24 (0.2mm²)

AWG22 (0.35mm²)

AWG20 (0.5mm²)

50m ~ 200m

AWG18 (0.75mm²)

AWG16 (1.5mm²)

AWG14 (2.0mm²)

Over 200m

AWG16 (1.5mm²)

AWG13 (2.5mm²)

AWG11 (4.0mm²)

4Ω

Upto 10m

AWG18 (0.75mm²)

AWG18 (0.75mm²)

AWG16 (1.5mm²)

10m ~ 30m

AWG13 (2.5mm²)

AWG13 (2.5mm²)

AWG11 (4.0mm²)

Over 30m

Not recommended

Not recommended

Not recommended

ES120P

ES250P

ES500P

83Ω

40Ω

20Ω

NOTE: 

Only connect one output – either 100V or 4Ω

INPUT CONNECTIONS

When wiring balanced inputs, wire the male plug so that it mates with the female 
XLR on the back of the amplifier. Follow the pin outs listed in the diagram below.

When wiring as a unbalanced input, wire the male plug so that it mates with the 
female XLR on the back of the amplifier.
Connect Cold- to Gnd as there is no cold signal available in an unbalanced 
connection.

Pin 1 Gnd

Male XLR

Female XLR

Pin 3 Cold-

Pin 2 Hot+

Pin 2 Hot+

Pin 3 Cold-

Pin 1 Gnd

Minimum total 

speaker impedance

ES120P only

Содержание ES120P

Страница 1: ...INSTALLATION AND OPERATION MANUAL ESP SERIES POWER AMPLIFIERS ES120P ES250P ES500P ...

Страница 2: ...tez tous les avertissements 4 Suivez toutes les avertissements 5 N utilisez pas ce produit pre s de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une e toffe se che 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez pre s aucunes sources de chaleur comme radiateurs registres de chaleur fours ou les autres e quipements ...

Страница 3: ...ing flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVIC...

Страница 4: ...500W 100V and 4Ω outputs XLR Through Output Level Adjustment 2 RU PROTECTION FEATURES Short circuit protection Over load protection Thermal protection ESP AMPLIFIER BLOCK DIAGRAM FEATURES PROTECTION FEATURES ESP SERIES INSTALLATION AND OPERATION MANUAL 4 ...

Страница 5: ...the amplifier is in protection due to a short circuit or overload condition at the output terminals SIGNAL This LED indicates the unit is outputting a signal POWER This LED indicates the unit is on POWER SWITCH This switches the power to the unit on and off The up position is on ES250P shown ES500P shown 2 2 3 3 4 1 4 ...

Страница 6: ...e run above the 12 o clock position half way to avoid clipping the input stage SPEAKER OUTPUT Speaker connections are provided on screw terminals 4Ω low impedance and 100V IMPORTANT If you are using the 100V output you must connect the jumper link between 4Ω and OT IN only for ES120P MINIMUM IMPEDANCE ES120P ES250P ES500P DISTRIBUTED LINE OUTPUT 100V 83Ω 40Ω 20Ω LOW IMPEDANCE OUTPUT 4Ω 4Ω 4Ω NOTE ...

Страница 7: ...nnector will accept The longer the speaker lead the greater the losses which will result in reduced power and less damping at the load We recommend using a heavy duty two core flex four core flex if bi amping 10 to 12 gauge 2mm2 to 2 5mm2 or 50 0 25 or equivalent as a minimum SPEAKER OUTPUT The output terminal strip accepts wire sizes from 16 22AWG 1 5mm2 0 35mm2 or spade lugs The following table ...

Страница 8: ...ound Output is short circuit Input is overloaded Output is being over driven Check speaker loads for shorts Reduce input level at source Reduce volume levels on rear panel No sound but amplifier is on Volume controls down Amplifier has overheated DC fuse s blown Check volume controls Check for obstructions above and below Make sure the amplifier is well ventilated Refer product to local Australian...

Страница 9: ...ESP SERIES INSTALLATION AND OPERATION MANUAL 9 DIMENSIONS ES120P ES250P ES250P ES250P ES120P ...

Страница 10: ...ESP SERIES INSTALLATION AND OPERATION MANUAL 10 DIMENSIONS ES500P ...

Страница 11: ...5dBr 80dBr All pots centre Max Output 1kHz 20kHz BW A Weighted THD N 1kHz 4Ω FREQ BAND 100V FREQ BAND 0 2 0 2 30Hz 20kHz 0 2 40Hz 20kHz 0 3 0 4 40Hz 20kHz 0 65 40Hz 20kHz 3dB below clipping 1kHz 20kHz BW Unity Gain A Weighted Inputs at centre position 3dB below clipping Freq Band 20kHz BW Unity Gain A Weighted Inputs at centre position 3dB below clipping Freq Band 20kHz BW Unity Gain A Weighted DC...

Страница 12: ...c 50Hz 100V Output 230Vac 50Hz 100V Output 1kHz Sine THERMAL DISSIPATION IDLE 1 8TH POWER 1 3RD POWER FULL POWER 30 71 272 96 361 67 412 85 95 54 589 42 787 03 948 54 Excludes Load Power 1W 3 412BTU Hr PRODUCT DIMENSIONS WITH RACK EARS WITHOUT RACK EARS 483mm x 293mm x 88mm 19 0 W x 11 5 D x 3 5 H 437mm x 293mm x 88mm 17 2 W x 11 5 D x 3 5 H 483mm x 353mm x 88mm 19 0 W x 13 9 D x 3 5 H 437mm x 353...

Страница 13: ...THD N 4Ω 1kHz 4Ω FREQ BAND 100V 1kHz 100V FREQ BAND 0 40 0 9 55Hz 13kHz 0 30 0 8 55Hz 13 5kHz 3dB below clipping 1kHz 20kHz BW Unity Gain A Weighted Inputs at centre position 3dB below clipping Freq Band 20kHz BW Unity Gain A Weighted Inputs at centre position 3dB below clipping 1kHz 20kHz BW Unity Gain A Weighted 3dB below clipping Freq Band 20kHz BW Unity Gain A Weighted AUDIO SENSITIVITY AUDIO ...

Страница 14: ... 1kHz Sine EFFICIENCY 1 8TH POWER 1 3RD POWER FULL POWER 20 32 57 230Vac 50Hz 100V Output 1kHz Sine THERMAL DISSIPATION IDLE 1 8TH POWER 1 3RD POWER FULL POWER 78 1156 1832 3020 Excludes Load Power 1W 3 412BTU Hr MISCELLANEOUS PRODUCT DIMENSIONS WITH RACK EARS WITHOUT RACK EARS 483mm x 455mm x 88mm 19 0 W x 17 91 D x 3 46 H 437mm x 455mm x 88mm 17 2 W x 17 91 D x 3 46 H SHIPPING DIMENSIONS 545mm x...

Страница 15: ...ESP SERIES INSTALLATION AND OPERATION MANUAL 15 NOTES ...