AUSTRALIAN MONITOR AMIS120XL Series Скачать руководство пользователя страница 3

Power Switch and “On” LED

The black rocker switch on the right hand side of the front panel is used to switch the amplifier on and off.
The ‘up’ position is on. When the amplifier is connected to an appropriate AC power source and is
switched on, the blue LED will illuminate. This LED will always be on when operating on 24VDC.

Signal LED

The green “Signal” LED located next to the ’On’ LED indicates that the AMIS120XL is passing audio. The
signal LED is a simple method to trouble-shoot installations especially in multi-amplifier projects.

Rack Mounting

The AMIS120XL is supplied with rack ears attached to allow mounting within a standard 19” equipment
rack. As is the case with almost all audio products, adequate ventilation and air flow is required. When
installing multiple AMIS amplifiers within the one rack, it is recommended that at least 1 rack unit of
ventilation space is left between every two amplifiers.

For table or shelf mounting, the rack ears can be removed using a screwdriver. Once the rack ears are
removed, please reinstall the screws.

Rear Panel Features

AC Power Inlet

The 3 pin IEC power inlet is located at the bottom left of the rear panel and accepts a standard mains power
lead fitted with an IEC connector.  The operating voltage is 115volt @60 Hz and the inlet is equipped with
an in-built AC fuse holder fitted with a 8 Amp slow blow fuse plus a spare fuse. Power consumption is 250
watts (max).

---Please ensure that the mains power cord is disconnected before attempting to check or replace this
fuse.---

24 Volt DC Power Inlet

The AMIS120XL features optional 24VDC power to run off a battery supply if required. This is connected
via the rear terminal strip. The front panel Power Switch will not switch DC power ‘on’ or ‘off’ in DC
operation. In this mode the amplifier is always ‘on’.

Содержание AMIS120XL Series

Страница 1: ...nd can be used for either low impedance 4 or 8 ohm or 25v 70v line speaker systems A host of unique features including multiple levels of muting a VOX relay output Transformer Balanced 600 Ohm Telephone input 24 VDC operation and VCA master level control make the AMIS120XL a very flexible amplifier The unit can be mounted in a standard 19 equipment rack rack ears supplied or it can be located on a...

Страница 2: ... of mids in the system The control allows for 10dB of cut or boost at 600Hz Depending on the speakers and application a small cut decrease in the mids normally makes the system sound warmer If no mid cut or boost is required the control should be left in the center 0 position Treble Control The Treble control is part of a 3 band equalization system within the AMIS120XL The Treble control allows th...

Страница 3: ...he one rack it is recommended that at least 1 rack unit of ventilation space is left between every two amplifiers For table or shelf mounting the rack ears can be removed using a screwdriver Once the rack ears are removed please reinstall the screws Rear Panel Features AC Power Inlet The 3 pin IEC power inlet is located at the bottom left of the rear panel and accepts a standard mains power lead f...

Страница 4: ...Open and NC Normally Closed The NO or NC selection provides the installer with the option of the relay either opening or closing a contact This feature is normally used in conjunction with relay override attenuators volume controls In this application the relay output could trigger an accessory power supply which in turn bypasses the remote attenuators The result is that priority inputs will alway...

Страница 5: ...c or professional tape recorders The output level of the tape output is governed by the 8 input controls of the AMIS120XL The front panel master control does not affect the tape output In a practical situation this allows for on the fly changes to the power amplifier level to turn the PA system up or down without affecting the signal being recorded Line Output A 3 pin male XLR socket is provided t...

Страница 6: ...e input See XLR Microphone Inputs Phantom Power should only be used on balanced electret microphones Using phantom power with unbalanced microphones may damage the microphone Muting The AMIS120XL includes an advanced priority muting system which is installer adjustable When shipped the AMIS120XL has three priority inputs From the factory Input 1 has overall priority and mutes inputs 2 8 when signa...

Страница 7: ...g particular attention to cords and plugs convenience receptacles and the point where they exit from the appliance 7 Always operate the unit with the AC ground wire connected to the electrical system ground Precautions should be taken so that the means of grounding of a piece of equipment is not defeated 8 Mains voltage must be correct and the same as that printed on the rear of the unit Damage ca...

Страница 8: ...be unplugged from the outlet when left unused for a long period of time 20 Service Information Equipment should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the equipment C The equipment has been exposed to rain D The equipment does not appear to operate normally or exhibits a marked chang...

Отзывы: