AUSTRALIAN MONITOR AMIS120 Series Скачать руководство пользователя страница 3

Treble Control

Setting this control in the centre position will give an overall flat treble response. Adjusting 

 

the treble

control in a clockwise direction will provide up to 9 dB of treble boost @ 10kHz.  Adjusting the treble
control in a counter-clockwise direction will provide up to -9 dB of treble cut @ 10 kHz. It is recommended
to start with the treble control at the centre ‘0’ position and adjust if necessary.

Master Output Control

The master level pot controls the overall output level of the amplifier depending on the levels set for the
individual input channels as detailed above.  Start with the control set to level ‘0’ and turn clockwise until
the desired output level of the amplifier is reached. The Master Output Control can also be operated via
remote VCA (see rear panel description)

Page Chime Enable Button

This allows the user to disable or enable the Pre-Announce Chime. This switch does

 

not activate the chime.

Activation is accomplished via the rear panel barrier strip (normally wired to a paging microphone). If the
pre-announce chime is connected to a paging microphone (meaning that it would be activated by the switch
on the microphone), the Page Chime Enable switch on the front panel of the amplifier allows the user to
disable the chime function on those occasions when it is not require

All Call Button

When pressed, the All Call button will connect the 70 volt output of the amplifier to all 6 of the switched
outputs (if connected).  Depressing this button again will disconnect the switched outputs.  This switch is
“push on-push off” and is non-interlocking.

Speaker (Zone) Selector Switches

These 6 black buttons are for switching the 70 volt output of the amplifier to any combination of the 6
available speaker zones.  The switches are “push on-push off” and are non-interlocking (both with each
other and with the all-call button).  The maximum capacity of each speaker zone is 60 watts so care should
be taken to ensure that no individual zone is loaded down with any more than 60 watts, always
remembering that the total load for the AMIS60 is 60 watts and for the AMIS120, 120 watts in total.  Eg;  it
is possible on the AMIS120 to safely have one zone loaded with 60 watts and the remaining five loaded
with 12 watts each.

Power Switch

This switch controls the switching of AC power to the amplifier.  Rocking this switch upwards

 

turns ‘on’

AC power to the amplifier while rocking the switch downwards turns power ‘off’ to the amplifier. A blue
LED above the switch will indicate whether the amplifier is switched ‘on’ or ‘off’. This will not switch DC
power ‘on’ or ‘off’ in DC operation. In DC operation mode, the amplifier is always ‘on’.

Содержание AMIS120 Series

Страница 1: ...MIS120 will deliver 120 watts into a load of 4 or 8 ohms 25 volt or 70 volt line Both Models feature 4 universal mic line inputs a transformer balanced 600 ohm telephone input and an insert point for additional EQ or feedback exterminator if required The AMIS60 120 also feature a dual RCA tape output while a balanced 700mV XLR output is also provided to feed up to six power amplifiers Other standa...

Страница 2: ...trols set to level 0 and turn the controls clockwise until the desired mix level for each channel is reached Bass Control Setting this control in the centre position will give an overall flat bass response Adjusting the bass control in a clockwise direction will provide up to 12 dB of bass boost 100 Hz Adjusting the bass control in a counter clockwise direction will provide up to 12 dB of bass cut...

Страница 3: ...r allows the user to disable the chime function on those occasions when it is not require All Call Button When pressed the All Call button will connect the 70 volt output of the amplifier to all 6 of the switched outputs if connected Depressing this button again will disconnect the switched outputs This switch is push on push off and is non interlocking Speaker Zone Selector Switches These 6 black...

Страница 4: ...ttempting to check or replace this fuse 24 Volt DC Power Inlet The AMIS60 AMIS120 feature optional 24VDC power to run off a battery supply if required This is connected via the rear terminal strip The front panel Power Switch will not switch DC power on or off in DC operation In this mode the amplifier is always on Speaker Output Terminal Strip The screw terminals on the left hand side of the stri...

Страница 5: ...se microphones can operate from an internal battery having phantom power available on the amplifier eliminates the need to regularly change batteries in the microphone While phantom power is not required for the more common Dynamic microphones it will not damage them providing they are balanced Do not plug an unbalanced microphone in to any amplifier or mixer when phantom power is switched on Line...

Страница 6: ...pe output remains unprocessed VOX Relay Output The terminal strip to the immediate right of the AC inlet features a relay output This relay is activated when signal is present at any of the priority inputs This would normally be inputs 1 and 2 however these channels can be removed from the priority bus via internal links see Muting further on in this manual The unit is shipped from the factory wit...

Страница 7: ...e priority by muting over background music VOX muting is available from channels 1 and 2 meaning that any signal on channels 1 and 2 mic or line will mute channels 3 4 The muted channels will automatically ramp back up to normal volume when the signal on channels 1 and or 2 is no longer active The amplifier ships with the VOX muting function enabled To disable the VOX muting disconnect the mains p...

Страница 8: ...ty 9 Have gain controls on amplifiers turned down during power up to prevent speaker damage if there are high signal levels at the inputs 10 Power down disconnect units from mains voltage before making connections 11 Never hold a power switch in the ON position if it won t stay there itself 12 Do not use the unit near stoves heat registers radiators or other heat producing devices 13 Do not block ...

Страница 9: ...lug has been damaged B Objects have fallen or liquid has been spilled into the equipment C The equipment has been exposed to rain D The equipment does not appear to operate normally or exhibits a marked change in performance E The equipment has been dropped or the enclosure damaged Engineered in Sydney Australia www australianmonitor com au International Sales Corporate Head Office Private Bag 149...

Отзывы: