(P/F) the fan shall switch on between 50degC - 70degC.
Stall the fan and wait for the unit to heat some more.
(P/F) The output shall mute to < 10V at a temp between 90–105degC
Values to be recorded
Value
Pass
Range
13a.
Fan turn on
50degC – 70degC
13b.
Thermal cutout
90degC – 105degC
14.
Final check for damage
Disconnect from test bench and inspect for scratches on external paint.
15.
Factory setting
Set up the unit for default factory setting as below:
Links:
a)
VOX Muting : Enable
Pot positions:
a)
Channel volume : min
b)
Master volume : min
c)
Bass/Treble : centre
Attach tested sticker.