AUSTRALIAN MONITOR AM21P Скачать руководство пользователя страница 12

PAGE 12

AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS  INSTALLATION AND OPERATION MANUAL

SPECIFICATIONS

Model

AM21P

AM22P

AM41P

AM42P

Conditions/Comments

Topology

Class-D

Class-D

Class-D

Class-D

Channels

2

2

4

4

Power Output (per channel)

Single Channel 4Ω

120W

210W

120W

210W

1kHz. 1%THD. -10W/+30W

4Ω (All Driven)

110W

200W

110W

200W

1kHz. 1%THD. -10W/+30W

Bridged 8Ω

230W

400W

230W

400W

1kHz. 1%THD. -10W/+30W

Single Channel 100V

120W

210W

120W

210W

1kHz. 1%THD. -10W/+30W

100V (All Driven)

110W

200W

110W

200W

1kHz. 1%THD. -10W/+30W

Maximum Output Level

28.24dBu (20Vrms)

31.25dBu (28.28Vrms)

28.24dBu (20Vrms)

31.25dBu (28.28Vrms)

20Hz–20kHz, <1%THD

System Gain

26dB

29dB

26dB

29dB

Frequency Response 4Ω

20Hz–25kHz

20Hz–25kHz

20Hz–25kHz

20Hz–25kHz

3dB below clipping, 
+0/-3dB.±5Hz

Frequency Response 100V

100Hz–16kHz

100Hz–16kHz

100Hz–16kHz

100Hz–16kHz

3dB below clipping, 
+0/-3dB.±5Hz

Signal to Noise Ratio

> 95 dBr

> 95 dBr

> 95 dBr

> 95 dBr

Max Output, 1kHz, 20kHz BW, 
A-Weighted

THD+N. 4Ω, 8Ω. 1kHz

< 0.2%

< 0.2%

< 0.2%

< 0.2%

3dB below clipping,  
1kHz. 20kHz BW, Unity Gain, 
A-Weighted

THD+N. 100V. 1kHz

< 0.3%

< 0.3%

< 0.3%

< 0.3%

3dB below clipping,  
1kHz. 20kHz BW, Unity Gain, 
A-Weighted

Channel Separation (crosstalk)

> 65 dB (for < 1KHz) 
> 60 dB (for > 1KHz)

> 65 dB (for < 1KHz) 
> 60 dB (for > 1KHz)

> 65 dB (for < 1KHz) 
> 60 dB (for > 1KHz)

> 65 dB (for < 1KHz) 
> 60 dB (for > 1KHz)

20Hz–20kHz, Max output, 
Adjacent Channels

Damping Factor

> 90

> 90

> 90

> 90

20Hz–1kHz, 8Ω. ±10

Input Connectors

Two 1x3 terminal plug 

(3.81mm)

Two 1x3 terminal plug 

(3.81mm)

Four 1x3 terminal plug 

(3.81mm)

Four 1x3 terminal plug 

(3.81mm)

Input Impedance

30kΩ

30kΩ

30kΩ

30kΩ

Balanced, line to line

Output Impedance

80mΩ

80mΩ

80mΩ

80mΩ

Input Sensitivity

1.0 Vrms

1.0 Vrms

1.0 Vrms

1.0 Vrms

 ±0.2V. Level control at maximum

Input CMRR

> 55dB

> 55dB

> 55dB

> 55dB

20Hz–20kHz

Output Connectors

6 pin Screw Terminal  

per channel

6 pin Screw Terminal  

per channel

6 pin Screw Terminal  

per channel

6 pin Screw Terminal  

per channel

LED Status

Signal, Clip, Protect

Signal, Clip, Protect

Signal, Clip, Protect

Signal, Clip, Protect

User Controls

Gain, switches (Bridge,  

Limiter, VCA, GND lift)

Gain, switches (Bridge,  

Limiter, VCA, GND lift)

Gain, switches (Bridge,  

Limiter, VCA, GND lift)

Gain, switches (Bridge,  

Limiter, VCA, GND lift)

VCA Attenuation (via 
potentiometer)

500kΩ

500kΩ

500kΩ

500kΩ

Limiter

95W

200W

95W

200W

±5W, 5%THD

AC Input

100-240Vac, 50-60Hz

100-240Vac, 50-60Hz

100-240Vac, 50-60Hz

100-240Vac, 50-60Hz

±10%

AC Power Factor

0.97

0.99

0.99

0.99

Max Output, 1kHz

AC Connector

IEC 60320-C14

IEC 60320-C14

IEC 60320-C14

IEC 60320-C14

Maximum Inrush Current

18.8A

18.8A

18.8A

31.83A

264VAC, 53Hz

Overload Protection

Temperature, Over Voltage, 

Current Limit

Temperature, Over Voltage, 

Current Limit

Temperature, Over Voltage, 

Current Limit

Temperature, Over Voltage, 

Current Limit

Содержание AM21P

Страница 1: ...INSTALLATION AND OPERATION MANUAL AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS AM42P AM41P AM22P AM21P ...

Страница 2: ...minals and speaker wiring during normal operation 1 LISEZ ces instructions 2 Tenez ces instructions 3 Notez tous les avertissements 4 Suivez toutes les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez prè...

Страница 3: ... user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance For European Union countries This symbol on the product or its packaging indicates that this product must not be disposed of with other waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the ...

Страница 4: ...and Signal LED indicators Power factor corrected universal switch mode power supply Efficient front to back cooling Dual twin speed axial fans 6 pin output screw terminal per channel Custom designed 1RU heavy duty steel chassis Front rack mount ears Symmetrical layout even weight distribution PROTECTION FEATURES Short circuit protection Suppression of inrush current at mains turn on Internal indep...

Страница 5: ...e and return to normal operation The AMP series is also fitted with DC protection if there is a DC voltage at the output the protection LED will glow yellow It should be noted that the minimum load for the amplifier is 4 ohms per channel 8 ohms bridged If an overload occurs the amplifier will run into a current limit mode restricting the excess current beyond set limits 4 Clip Indicator This red L...

Страница 6: ...d speaker termination should be sourced from the 4Ω output of each channel respectively see Speaker Connector Wiring Diagram 8 Limiter Switch Turn the limiter switch on to engage the clip limiter circuitry The threshold level is referenced to the supply rail and the output voltage is sampled allowing true clip detection and limiting 9 VCA Switch Turn the VCA switch on to engage the voltage control...

Страница 7: ...hoenix type connector is provided on each input Pin 1 Hot non inverting or in phase Pin 2 Cold inverting or reverse phase Pin 3 Signal Ground 3 Level Control A potentiometer to provide attenuation to the signal input 4 VCA Control Connect an Australian Monitor RC1 remote panel or any 500kΩ potentiometer between the and terminals of the VCA input for external level control 5 Speaker Outputs The out...

Страница 8: ...ly force the unit into its thermal shutdown mode If the amplifiers are to be operated in an environment where the airflow is restricted such as sealed racks the cooling should be supplemented by extra cooling fans to evacuate the heated air and aid the flow of cool air through the unit Input Wiring IMPORTANT Do not directly connect pin 3 on the amplifier s input to the amplifier s chassis speaker ...

Страница 9: ...ers or stray magnetic fields from mains transformers are often the cause of this problem It is generally more difficult to eliminate this kind of interference but again moving the source away or providing a magnetic shield i e a steel shield should help Earth loops can arise from the interfacing of the various pieces of equipment and their connections to various safety earths This is by far the mo...

Страница 10: ...nsure that there are no open or short circuited conductors Ensure that the power handling of your load speakers can adequately cope with the power output of the amplifier Before operating your AMP Series amplifier ensure that The BRIDGE Switch is not engaged if you are not running the amp in bridged mode Powering Up REMEMBER The amplifier should be the last piece of equipment that you turn on and ...

Страница 11: ...the leading edge of the fan blades and reduce their cooling efficiency The time taken for this to happen will depend on the environment and the amount of use The fan blades are accessible once the lids are removed and can be easily cleaned You need only hold the fan rotor still and wipe the dust off the blades Many users stall the fan and use compressed air to blow the dust off the fan blades It i...

Страница 12: ...or 1KHz 65 dB for 1KHz 60 dB for 1KHz 20Hz 20kHz Max output Adjacent Channels Damping Factor 90 90 90 90 20Hz 1kHz 8Ω 10 Input Connectors Two 1x3 terminal plug 3 81mm Two 1x3 terminal plug 3 81mm Four 1x3 terminal plug 3 81mm Four 1x3 terminal plug 3 81mm Input Impedance 30kΩ 30kΩ 30kΩ 30kΩ Balanced line to line Output Impedance 80mΩ 80mΩ 80mΩ 80mΩ Input Sensitivity 1 0 Vrms 1 0 Vrms 1 0 Vrms 1 0 ...

Страница 13: ...48 428 Excludes Load Power 1W 3 412BTU Hr Full Power 218 375 416 785 Excludes Load Power 1W 3 412BTU Hr Dimensions W x D x H 483mm x 448mm x 44mm 19 x 17 63 x 1 73 483mm x 448mm x 44mm 19 x 17 63 x 1 73 483mm x 448mm x 44mm 19 x 17 63 x 1 73 483mm x 448mm x 44mm 19 x 17 63 x 1 73 Not including rack ears Shipping Dimensions W x D x H 545mm x 515mm x 105mm 21 46 x 20 28 x 4 13 545mm x 515mm x 105mm ...

Страница 14: ...PAGE 14 AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL NOTES ...

Страница 15: ...PAGE 15 AMP SERIES CONSTANT VOLTAGE INSTALLATION AUDIO POWER AMPLIFIERS INSTALLATION AND OPERATION MANUAL NOTES ...

Страница 16: ...ENGINEERED BY AUSTRALIAN MONITOR Address Level 7 130 Pitt Street Sydney NSW 2000 Australia Website www australianmonitor com au International enquiries email international australianmonitor com au ...

Отзывы: