AUSTRALIAN MONITOR ACM250 Скачать руководство пользователя страница 2

Power Output

250 watts RMS

Maximum Load

40 Ohms @ 100 Volts

Power Bandwidth

60Hz - 15kHz < 0.5% THD

Frequency Response

60Hz - 15kHz (± 3dB)

Total Harmonic Distortion

0.5% @ 1kHz rated power

Signal To Noise Ratio

-74dB with all controls at their centre position

Tone Controls

Bass @ 100Hz: Boost +12dB Cut -12dB; Mid @ 600Hz: Boost +12dB, Cut -12dB;

Treble @ 10kHz: Boost +9dB Cut -9dB

Inputs

Six mic/aux universal inputs with XLR female mic sockets and dual RCA Phono aux sockets

Input Sensitivity

Mics: 1mV @ 200 Ohms; Aux 1 - 5: 75mV @ 47K Ohms; Aux 6: 300mV @ 47K Ohms

Outputs

Speaker: 100, 70 Volts, 4 Ohms; Tape: 350mV @ 10K Ohms; Line: Balanced 700mV

Phantom Power

18 Volts DC on all Mic inputs

Controls

6 Input channel gain controls, 1 Bass control, 1 Mid Control, 1 Treble control, 

1 Master gain control, Phantom Power on/off switch (on rear panel)

Indicators

Power ”on“ and ”Protect“ LED

Power Source

AC 230/240V - 60Hz, 110V - 50Hz (special) 3 pin IEC connector

Power Consumption

400 Watts

Protection

Current Limiter protection, plus AC and DC fuses

Dimensions/Weight

88mm H x 480mm W x 330mm D (Chassis Dimensions only). 15kg

Rack Mounting

Standard

Tone Generators

Built-in four tone generator module. 

Includes Bell, Pre-Announce, Alert and Evac Tones

Muting

Built-in VOX muting. Channels 1 and 2 will mute channels 3, 4, 5 and 6

Engineered and Distributed By AUDIO TELEX COMMUNICATIONS PTY LTD (

ABN 78 001 345 482

), 149 Beaconsfield Street, Silverwater, Sydney, NSW, 2128 Australia

NSW Tel: (02) 9647 1411 Fax: (02) 9648 3698   VIC Tel: (03) 9890 7477 Fax: (03) 9890 7977   QLD Tel: (07) 3852 1312 Fax: (07) 3252 1237   WA Tel: (08) 9228 4222 Fax: (08) 9228 4233   

TAS Tel: (03) 6228 6373 Fax: (03) 6278 1063   SA Tel: (08) 8352 4444 Fax: (08) 8352 4488   Export Enquiries: [email protected]   

Website: www.australianmonitor.com.au

ARCHITECTURAL AND ENGINEERING SPECIFICATIONS

The mixer amplifier shall have six universal inputs each comprising of a balanced microphone with XLR

female sockets and an auxiliary input using dual RCA sockets. A balanced XLR output to drive addi-

tional power amplifiers shall also be provided. 

The amplifier master section shall include one master gain control, three EQ controls, one with 12dB of

cut and boost at 100Hz, one with 12dB cut and boost at 600Hz and the other with 9dB of cut and boost

at 10kHz. Speaker outputs shall be transformer isolated at 100 volt, 70 volt and 4 ohms. The amplifier

must be capable of delivering 250 watts RMS into a 40 inductive ohm load, with less than 0.5% distor-

tion measured at 1kHz and with system hum and noise less than -74dB. 

The amplifier shall be an Australian Monitor Installation Series model ACM250.