Power Output

120 watts RMS

Maximum Load

80 Ohms @ 100 Volts

Power Bandwidth

60Hz - 15kHz < 0.5% THD

Frequency Response

60Hz - 15kHz (± 3dB)

Total Harmonic Distortion

0.5% @ 1KHz rated power

Signal To Noise Ratio

-74dB with all controls at their centre position

Tone Controls

Bass @ 100Hz: Boost +12dB Cut -12dB; Mid @ 600Hz: Boost +12dB Cut -12dB;

Treble @ 10kHz: Boost +9dB Cut -9dB

Inputs

Eight mic/aux universal inputs with XLR female mic sockets and dual RCA Phono aux sockets

Input Sensitivity

Mics: 1mV @ 200 Ohms; Aux: 90mV @ 47K Ohms with selectable 9, 12, 15dB Pads

Outputs

Speaker: 100, 70 Volts, 4 & 8 Ohms; Tape: 350mV @ 10K Ohms; Line: Balanced 700mV

Phantom Power

18 Volts DC on all Mic inputs (dip switch per channel)

Controls

8 Input channel gain controls, 1 Bass control, 1 Mid Control, 1 Treble control, 

1 Master gain control, VCA rear panel strip, Dip Switch per Channel for 

line sensitivity and phantom power and a vox relay ouput on the rear panel.

Indicators

Power ”on“ LED, signal present LED

Power Source

AC 230/240V - 60Hz, 110V - 50Hz (special) 3 pin IEC connector

Power Consumption

250 Watts

Protection

Soft limiter for overload and overdrive protection, plus AC and DC fuses

Dimensions/Weight

88mm H x 480mm W x 280mm D (Chassis Dimensions only). 12kg

Rack Mounting

Standard

Tone Generators

Built-in four tone generator module. 

Includes Bell, Pre-Announce, Alert and Evac Tones

Muting

Built-in VOX muting. Channel 1 will mute channels 2 to 8, channel 2 mutes 3 - 8, 

channel 3 mutes 4 - 8. A vox triggered relay (for external devices) is also included.

ARCHITECTURAL AND ENGINEERING SPECIFICATIONS

The mixer amplifier shall have eight universal input channels, each comprising of a balanced micro-

phone input with XLR female sockets and an auxiliary input using dual RCA sockets. A balanced XLR

output to drive additional power amplifiers shall also be provided.  The master output may be con-

trolled remotely via a VCA control. An insert point is provided for the addition of signal processing. A

vox triggered relay output (for external devices) shall also be included.

The amplifier master section shall include one master gain control, three EQ controls, one at 100Hz with

12dB of cut and boost, one at 600Hz with 12dB cut and boost and the other with 9dB of cut and boost

at 10kHz. Speaker outputs shall be transformer isolated at 100 volt, 70 volt, 4 & 8 ohms. The amplifier

must be capable of delivering 120 watts RMS into an 80 inductive ohm load, with less than 0.5% 

distortion measured at 1kHz and with system hum and noise equal to or better than -74dB. 

The amplifier shall be an Australian Monitor Installation Series model ACM120XL.

Engineered and Distributed By AUDIO TELEX COMMUNICATIONS PTY LTD (

ABN 78 001 345 482

), 149 Beaconsfield Street, Silverwater, Sydney, NSW, 2128 Australia

NSW Tel: (02) 9647 1411 Fax: (02) 9648 3698   VIC Tel: (03) 9890 7477 Fax: (03) 9890 7977   QLD Tel: (07) 3852 1312 Fax: (07) 3252 1237   WA Tel: (08) 9228 4222 Fax: (08) 9228 4233   

TAS Tel: (03) 6228 6373 Fax: (03) 6278 1063   SA Tel: (08) 8352 4444 Fax: (08) 8352 4488   Export Enquiries: [email protected]   

Website: www.australianmonitor.com.au

Отзывы: