26 / 32
7.13
Pneumatic system connection
When routing the air tubes, make sure that the tubes are clear of any moving
part. It may necessary to tie the tubes clear by using nylon tie straps or wire.
Failure to do so may result in safety failure which may result in damage or
personal harm.
System of the lift is connected) must be equipped with a
servicing unit composed of water separator, lubricator and
pressure reducer. These devices can be supplied by the
manufacturer on request.
•
Mount the solenoid air valve on the power-
side column and fix it using the screws
•
Connect the pneumatic lines pre-assembled on
the runways to the solenoid air valve;
•
Connect the pneumatic system of the lift and the
jack beam to the pneumatic supply at site;
•
Check the pneumatic control operations for
proper performance.
7.14
Make the electrical hookup to the power unit
The hookup work must be carried out by a qualified electrician.
Make sure that the power supply is right.
Make sure the connection of the phases is right.
Do not run the power unit with no oil.
Damage to pump can occur.
The power unit must be kept dry.
•
Fix the control panel onto the power-side column using the included screws.
•
Make the electric hookup to the hydraulic power unit referring to the wiring diagram using
included electric cable.
•
Make sure the connection of the phases is right and the lift is grounded.
If no special request, black wires are for phases, the blue is for neutral (for single
phase circuit), the yellow/green is for grounding.
7.15
Start up
During Start up procedure, observe all operating components and check for
proper installation and adjustment. Do not attempt to raise vehicle until a
thorough operation check has been completed.
•
Make sure that all columns are plumb and that the base plate of each column is square
•
Make sure the lift fixing to the ground using anchor bolts and all anchor bolts tightened
Содержание YL5000