AquaGo comfort / AquaGo comfort plus
Problem
Potential Cause
Resolution
The yellow status
LED 3 is off al-
though an oper-
ating mode was
selected.
Power swtich is OFF
Switch ON the appliance at the POWER switch.
Power supply to the appliance is
switched off
Switch on the power supply to the appliance.
Power supply was interrupted
Reset by switching OFF at the control panel, waiting
2 seconds and then switching on again.
If none of the measures in the troubleshooting chart proves successful, please contact your dealer,
the Truma Service Center at 1-855-558-7862 or one of our authorized service partners.
Furnace
Dometic DFSD 12111 Furnace
Introduction:
The following instructions are an extract from the Operation Manual published by the manufacturer Dometic
Corporation. These instructions are a guide to operation of the furnace only.
The manufacturers Operation Manual included with the product MUST be read in its entirety before operating this
appliance.
Should you require further information, contact Dometic https://www.dometic.com/en-us/outdoor/support
General Safety
The manufacturer states the following:
FIRE OR EXPLOSION HAZARD
Failure to obey the following warnings could result in property damage,
serious injury or death.
WARNING
•
Do
NOT
store gasoline, oil- or gasoline-soaked rags, or other flammable vapors and liquids inside storage
compartment(s)
•
BEFORE
refueling or parking near a gasoline pump, make sure ALL liquid propane (LP) gas appliances (vented to
the outside of the RV) are shut OFF. Otherwise, fumes from gasoline pumps could come into contact with an LP
gas appliance burner flame and ignite.
•
Turn OFF LP gas supply at the tank.
•
Keep the Furnace area free and clear of insulating material, as insulating materials may be combustible. Examine
the Furnace area after installation or when insulation is added.
•
Use only with the type of gas approved for the Furnace. Refer to the Furnace rating plate.
o
All DFSA, DFS, DFM, and DFLD models: LP ONLY
•
Do
NOT
overfill LP gas tanks. LP tanks must be filled by a qualified gas supplier only. Follow the tank
manufacturer’s operating instructions located on the tank.
•
Immediately shut down the Furnace and call a service agency if the Furnace cycles erratically or delays on
ignition.
•
Shut OFF the gas valve to the Furnace before shutting off the electrical supply if the gas supply fails to shut off,
or if overheating occurs.
Содержание X13 2021
Страница 76: ...www ausrv com Ph 833 872 8778 76 Electrical Diagram ...
Страница 80: ...www ausrv com Ph 833 872 8778 80 Hub Assembly ...
Страница 81: ...www ausrv com Ph 833 872 8778 81 Trailing Arms and Bushes ...
Страница 105: ...www ausrv com Ph 833 872 8778 105 Trip Name Date Miles Start Miles Finish Cumulative Miles ...