Gas Type and Gas Pressure 

 

Do not use any other gas type except the one specified on the data label.  

For LP Gas Model (Supplied with regulator type 73-1-8 AGA 3884 and Hose TPA type APH801 6356) 

This model of appliance is suitable for use with propane gas and are set to operate under gas pressure of 
2.75kPa. 
 

*The LP gas regulator and hose supplied are for outdoor installations only.  
 
Indoor installations must be installed in accordance with the requirements of AS/NZS5601.1, Local 
State and Territory regulations, municipal building codes, and any other relevant statutory 
regulations. 

 

For Natural Gas Model (Supplied with Bromic type 980L regulator AGA 5862) 

This model of appliance is only suitable for use with natural gas and are set to operate under gas pressure 
of .90kPa. 

WARNING! It is hazardous to attempt to use other types of gas with this appliance. 
 
The Gas Inlet is located for model Y028NGWF/Y028LPWF 300mm up from the base and 25mm in from 
the RH side leg. For model Y018NGWF/Y018LPWF the gas inlet is located 260mm up from the base 
and in line with the RH leg side. 
Gas Cylinder (For LP Gas Model only) 

Only cylinders which comply with AS2030.1 should be used. The appliance is suitable for use with gas 
cylinders of 3.9 kg or greater.  
The gas cylinder should not be dropped or handled roughly!  If the appliance is not in use, the cylinder must 
be disconnected.  Replace the protective cap on the cylinder after disconnecting the cylinder from the stove.  

WARNING! It may hazardous to use a damaged or dented gas cylinder. 

Cylinders must be stored outdoors in an upright position and out of the reach of children.  The cylinder must 
never be stored under direct sunlight or where temperatures can reach over 50

C.  Do not store the cylinder 

near flames, pilot lights or other sources of ignition.  DO NOT SMOKE around the cylinders. 

WARNING! It may hazardous to store gas cylinder in an enclosed place. 
 
Exchanging of the gas cylinder 

Ensure the valve on the cylinder is closed. Remove the hose assembly. Connect in reverse order and check 
for gas leakage at all joints with soapy water. 

 
Gas Hose Assembly 

Use only the hose assembly supplied with the appliance. Use only a gas hose that complies with 
AS/NZS1869. The appliance requires a ‘Class B’ Gas hose.  The hose should be secured to the regulator 
and the appliance with spanner. Use the hose with the right threads, DO NOT use adaptors. Inspect the 
hose assembly before each use of the appliance. 
The life expectancy of the hose is estimated at 5 years.  It is recommended that the hose is changed every 5 
years. 
The use of the wrong hose is unsafe. Always check that you have the correct items before operating the 
appliance. 

WARNING! It may hazardous to use the wrong type of hose. 

 The length of the hose must not excess 1.8 metres (maximum). Worn or damaged hose must be replaced if 
there is evidence of excessive abrasion or wear.  A replacement hose is supplied by Austcrown, refer to 
contact detail. Ensure that the hose is not obstructed, kinked, or in contact with any part of the appliance 
other than at its connection.  

WARNING! It may hazardous to use a damaged hose. 

 

Regulator

 

Use only the gas regulator supplied with the appliance which complies with AS4618. The appliance must be 
used with a LOW pressure regulator with output pressure of 2.75kPa for LP gas and 0.90kPa for Natural Gas. 
Use a regulator with the right threads.  
 

For Propane Gas Model: 73-1-8, AGA 3884 
Outlet Pressure: 2.75kPa 
Flow Capacity: 3kg/hr (For Y018LPWF) 

Flow Capacity:

 10kg/hr (For Y028LPWF) 

Inlet Fitting: CGA-510 POL with Soft Nose 
Outlet Fitting: 3/8” BSPF Thread 

For Natural Gas Model: Bromic 980L, AGA 5862 
Outlet Pressure: 0.90kPa 
Flow Capacity:  2 M

3

/hr (For Y018NGWF) 

Flow Capacity:

  3 M

3

/hr (For Y028NGWF) 

Inlet Fitting: ½” BSPF Thread 
Outlet Fitting: ½” BSPF Thread 

 

Содержание Y018LPWF

Страница 1: ...d before the appliance is used especially following disconnection and reconnection of the cylinder NEVER CHECK FOR LEAKS WITH A MATCH OR OPEN FLAME DO NOT STORE OR USE PETROLEUM PRODUCTS OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS APPLIANCE AN LP CYLINDER NOT CONNECTED FOR USE IN THIS APPLIANCE SHALL NOT BE STORED NEAR THIS APPLIANCE TO BE INSTALLED ON A FIREPROOF BASE ONLY FOR ...

Страница 2: ...se in this appliance shall not be stored near this appliance Ensure the gas hose is not placed under the appliance or allowed to contact any hot surfaces of the appliance This appliance must not be modified or changed in any way Disconnect the gas cylinder from the burner prior to storage It is also recommended that the gas cylinder be stored outdoors in a well ventilated area Do not use any other...

Страница 3: ...d doors Do not use any naked flame or other ignition source such as light switches power points mobile phones and pagers Do not operate any electrical equipment in the vicinity of a gas leak Contact your licensed gas fitter to repair the leak and re light the appliance NEVER attempt to repair the appliance yourself IT MUST BE SERVICED BY AN AUTHORIZED PERSON PART INDEX 1 Burner 2 Safety Switch A 3...

Страница 4: ... surrounding walls are constructed with a combustible material refer AS NZS5601 1 for information on the clearance required The appliance must be used on a level stable non flammable surface when in use This appliance is intended for commercial use only It is important that the ventilation openings of the appliance are not obstructed The appliance should be protected from direct draughts The appli...

Страница 5: ...Revision 2 November 2012 EXAMPLE 2 EXAMPLE 3 EXAMPLE 4 ...

Страница 6: ... other sources of ignition DO NOT SMOKE around the cylinders WARNING It may hazardous to store gas cylinder in an enclosed place Exchanging of the gas cylinder Ensure the valve on the cylinder is closed Remove the hose assembly Connect in reverse order and check for gas leakage at all joints with soapy water Gas Hose Assembly Use only the hose assembly supplied with the appliance Use only a gas ho...

Страница 7: ...xible hose is to be used DO NOT assemble beneath the appliance under direct sunlight or close to other sources of heat 6 The length of connection between the appliance and the main gas supply should not exceed 1 8m 7 Check for gas leakage at all joints with soapy water or other approved methods UNDER NO CIRCUMSTANCES SHOULD A NAKED FLAME BE USED IN CHECKING FOR GAS LEAKS OPERATING INSTRUCTIONS Ign...

Страница 8: ...012 If the burner fails to operate correctly contact place of purchase or authorised agent for advice and service RECOMMENDED POT SIZE Y018 Series Minimum Ø44cm Maximum Ø49cm Y028 Series Minimum Ø44cm Maximum Ø61cm CAUTION ...

Страница 9: ...r advice TROUBLESHOOTING DO NOT MODIFY THIS APPLIANCE If the appliance cannot be adjusted to perform correctly contact after sales service contact details this page Problem Possible Cause Solution No Ignition Main Gas Valve is not turned on Air trapped in the gas hose The safety valve is not open Turn off the gas valve once and then turn it on fully Repeat the ignition process until all air in the...

Страница 10: ...y unscrewing centrally located 10mm hex screws Note the pilot and thermocouple assembly is secured independently via a bracket onto the burner locating frame This can also be removed to prevent damage to the assembly Replace in reverse order ensuring all connections are gas tight Pilot and flame safeguard thermocouple removal The gas control needs to be removed to allow removal of the pilot and th...

Страница 11: ...Revision 2 November 2012 ...

Отзывы: