IMPORTANT 

 

Read the following instructions carefully and be sure your appliance is properly installed, assembled and 
cared for.  Failure to follow these instructions may result in serious bodily injury and/or property damage. 

 

This appliance is intended for commercial use only. 

 

This appliance is adjusted to operate on the gas specified on the gas type label and on the data label. 
The gas type label is located front of the appliance and data label RH side front of the appliance. If in 
doubt as to the type of gas available contact the network operator or gas supplier for confirmation of gas 
type. 

 

It is the operator’s responsibility to check the appliance is properly assembled and maintained 

 

The heat shield located beneath the burner must always be in place during burner operation. 

 

Do not lay the gas cylinder down – cylinder should be stored / used in the upright position  

 

Hazardous fire or explosion may result if instructions are ignored. 

 

Leak test all connections before use and after each cylinder refill 

 

Never check for leaks with a match or naked flame 

 

DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE. 

 

DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE. 

 

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.  

 

Use only in well ventilated areas, but not facing against any draught. 

  WARNING! Carbon monoxide hazard – this appliance can produce carbon monoxide which has no 

odour.  Using the appliance in an enclosed space (for example, boats, caravan, tent, car, and mobile 
home) may cause death.   

 

Do not move the appliance during operation  

 

Avoid twisting or kinking of the flexible gas hose 

 

Do not use the appliance near any air opening(s) into buildings (i.e. windows, doorways, ventilation ducts 
etc.) 

 

Leak test all connections before use and after each cylinder refill – refer “How to Check for Gas Leaks” in 
this manual. 

 

An LP gas cylinder not connected for use in this appliance shall not be stored near this appliance. 

 

Ensure the gas hose is not placed under the appliance or allowed to contact any hot surfaces of the 
appliance  

 

This appliance must not be modified or changed in any way. 

  Disconnect the gas cylinder from the burner prior to storage. It is also recommended that the gas 

cylinder be stored outdoors in a well-ventilated area. 

 

Do not use any other gas type except the one specified on the label/data plate.  

 

Use only the gas regulator and hose supplied with this appliance. An inferior or a damaged regulator 
could cause an incomplete combustion or other troubles with the burner.  

 

Do not leave the burner unattended when in use. Always turn off the burner and the main gas valve after 
each use. 

 

Do not use the burner as a space heater under any circumstance. 

 

Do not cover or blow off the flames. This could cause gas leaking.  

 

Always keep inflammable materials away from the burner. 

 

Make sure that you use cooking woks, pots or pans that sit firmly on the trivet. Do not use pots that are 
too small / large for the burner size, as they could be unstable on the trivet.   

 

If abnormal combustion is observed when in use, turn off the main gas valve and examine the burner 
(Refer to Trouble-Shooting Guide). 

 

Do not attempt to repair the burner yourself. 

 

Do not install into a marine environment. 

 

This appliance is suitably protected while it is on its way to you. All materials used for packaging are 
suitable for recycling. Please make a contribution to protecting the environment by disposing of the 
packaging appropriately 

 
HOW TO CHECK FOR GAS LEAKS 

 

To check for leaks, turn on gas supply with the appliance gas valves in the OFF position (DO NOT 
IGNIGHT) Check for leakage by brushing a solution of soapy detergent and water onto the connection 
points at the bottle and the appliance.  If bubbling is evident (it may take more than 30 seconds to 
appear) this indicates a gas leak is present. If disassembling, cleaning, reassembling and tightening the 
connection does not rectify the leak you should close the gas cylinder valve and consult the place of 
purchase for assistance. 

Содержание Y018LPWF

Страница 1: ...d before the appliance is used especially following disconnection and reconnection of the cylinder NEVER CHECK FOR LEAKS WITH A MATCH OR OPEN FLAME DO NOT STORE OR USE PETROLEUM PRODUCTS OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS APPLIANCE AN LP CYLINDER NOT CONNECTED FOR USE IN THIS APPLIANCE SHALL NOT BE STORED NEAR THIS APPLIANCE TO BE INSTALLED ON A FIREPROOF BASE ONLY FOR ...

Страница 2: ...se in this appliance shall not be stored near this appliance Ensure the gas hose is not placed under the appliance or allowed to contact any hot surfaces of the appliance This appliance must not be modified or changed in any way Disconnect the gas cylinder from the burner prior to storage It is also recommended that the gas cylinder be stored outdoors in a well ventilated area Do not use any other...

Страница 3: ...d doors Do not use any naked flame or other ignition source such as light switches power points mobile phones and pagers Do not operate any electrical equipment in the vicinity of a gas leak Contact your licensed gas fitter to repair the leak and re light the appliance NEVER attempt to repair the appliance yourself IT MUST BE SERVICED BY AN AUTHORIZED PERSON PART INDEX 1 Burner 2 Safety Switch A 3...

Страница 4: ... surrounding walls are constructed with a combustible material refer AS NZS5601 1 for information on the clearance required The appliance must be used on a level stable non flammable surface when in use This appliance is intended for commercial use only It is important that the ventilation openings of the appliance are not obstructed The appliance should be protected from direct draughts The appli...

Страница 5: ...Revision 2 November 2012 EXAMPLE 2 EXAMPLE 3 EXAMPLE 4 ...

Страница 6: ... other sources of ignition DO NOT SMOKE around the cylinders WARNING It may hazardous to store gas cylinder in an enclosed place Exchanging of the gas cylinder Ensure the valve on the cylinder is closed Remove the hose assembly Connect in reverse order and check for gas leakage at all joints with soapy water Gas Hose Assembly Use only the hose assembly supplied with the appliance Use only a gas ho...

Страница 7: ...xible hose is to be used DO NOT assemble beneath the appliance under direct sunlight or close to other sources of heat 6 The length of connection between the appliance and the main gas supply should not exceed 1 8m 7 Check for gas leakage at all joints with soapy water or other approved methods UNDER NO CIRCUMSTANCES SHOULD A NAKED FLAME BE USED IN CHECKING FOR GAS LEAKS OPERATING INSTRUCTIONS Ign...

Страница 8: ...012 If the burner fails to operate correctly contact place of purchase or authorised agent for advice and service RECOMMENDED POT SIZE Y018 Series Minimum Ø44cm Maximum Ø49cm Y028 Series Minimum Ø44cm Maximum Ø61cm CAUTION ...

Страница 9: ...r advice TROUBLESHOOTING DO NOT MODIFY THIS APPLIANCE If the appliance cannot be adjusted to perform correctly contact after sales service contact details this page Problem Possible Cause Solution No Ignition Main Gas Valve is not turned on Air trapped in the gas hose The safety valve is not open Turn off the gas valve once and then turn it on fully Repeat the ignition process until all air in the...

Страница 10: ...y unscrewing centrally located 10mm hex screws Note the pilot and thermocouple assembly is secured independently via a bracket onto the burner locating frame This can also be removed to prevent damage to the assembly Replace in reverse order ensuring all connections are gas tight Pilot and flame safeguard thermocouple removal The gas control needs to be removed to allow removal of the pilot and th...