Placement / External Factors
Tips for installing the AOne system
The number and type of devices being used and the environment and materials in the space
surrounding the hub and devices can impact the overall system performance.
1. Ensure your Hub is in a central location with your devices no more than three device hops to
the hub.
2. The distance between Devices and the Hub will need to be closer if the walls or ceilings
between them are composed of solid material.
3. The distance between devices can be further apart in more open spaces (up to 20m).
4. Metal can also affect the system performance by reducing the signal strength between
Devices (metal wall boxes, enclosed metal light fixtures, metal cable trays etc.).
5. The different types of Devices can also impact how many Devices a Hub can support.
For example Devices that are sending energy information (eg. Double Socket) or occupancy
(eg. PIR) information back to the Hub will reduce the max number of Devices that a Hub can
effectively handle.
Kinetic Switches will perform better in small to medium sized Systems.
The more information being sent to a Hub will cause latency across the AOne System.
6. If the AOne System is being used in a large space consider breaking the area into zones with a
Hub per zone
Eg. left side and right side of the building OR a Hub per floor
Note that the AOne App can support multiple hubs with one account.
7. Remove the temptation for users of the space to use a manual switch.
This will cause performance issues across the System and even stop Devices attached to the
switch to Mesh (or hop messages across the space) and stop working all together.