7
Selecting the proper location for temperature
regulator
Proper operation of the regulator is greatly affected by its location. Installing it in a place
with no air circulation or exposed to direct sunlight causes improper regulation of tem-
perature. In order to ensure proper operation, the regulator must be installed on an
interior wall of a building (partition wall). A place should be selected that is occupied
most frequently, providing undisturbed circulation of air. Avoid heat radiating devices
(television set, heater, refrigerator etc.) or places exposed to direct sunlight. In order to
avoid vibration, do not place the regulator in close vicinity of doors.