28
Technical specifications
Working temperature range:
0 – 35°C
Temperature measurement range:
5 – 30°C
Span:
±0,2°C / ±0,4°C / PWM
Dokładność wskazań temperatury:
±1°C
Number of temperature levels:
8 + 3
Number of programs:
8 for week days,
8 for Saturday, 8 for Sunday
Anti-freezing temperature:
4 – 10°C
Operating cycle:
weekly, programmable
Monitoring of operating state:
LED (the RT receiver) / LCD (the regulator)
Maximum load current for relay contacts:
resistive 16 A
inductive / capacitive 10 A
AURATON R30 RT power supply:
2 x AA alkaline battery
AURATON RT power supply:
230V AC, 50Hz
AURATON RT radio frequency:
868 MHz
AURATON RT operation range:
in a typical building, with standard construction
of walls – approx. 30 m;
an open space – up to 300 m
Disposing of the devices
Cleaning and maintenance
The devices are marked with the crossed waste bin symbol. According to
European Directive no. 2002/96/EU and the Act concerning used up electric
and electronic equipment, such a marking indicates that this equipment may
not be placed with other household generated waste.
The user is responsible for delivering the devices to a reception point for used-up
electric and electronic equipment.
• Clean the outside of the device with a dry cloth. Do not use from solvents
(such as benzene, thinner or alcohol).
• Do not touch the device with wet hands. It may cause electric shock or serious
damage to the device.
• Do not expose the device to excessive smoke or dust.
• Do not touch the screen with a sharp object.
• Avoid contact of the device with liquids or moisture.
Содержание R30 RT
Страница 1: ...R30 RT O W N E R S M A N U A L EN www auraton pl ...
Страница 2: ......
Страница 29: ......
Страница 30: ...A template for drilling holes for fastening the AURATON RT receiver 1 1 scale ...
Страница 31: ...A template for drilling holes for fastening the AURATON R30 RT regulator 1 1 scale ...
Страница 32: ...www auraton pl ver 20190218 ...