AURALIC LIMITED 

RM 19C, LOCKHART CENTRE, 301-307 LOCKHART ROAD, HK 

Phone: +852 6852 3312. Fax: +852 8199 9198 

Email: [email protected]. Website: www.auralic.com 

Содержание Merak

Страница 1: ...400W Power Amplifier Monoblock USER S GUIDE Revision 1 0 AURALIC LIMITED RM 19C LOCKHART CENTRE 301 307 LOCKHART ROAD HK Phone 852 6852 3312 Fax 852 8199 9198 Email support auralic com Website www auralic com ...

Страница 2: ... or liability for any errors or inaccuracies that may appear in this manual AURALiC inspire the music ActiveUSB AFN402 Alire Purer Power and their graphic logos are trademarks or registered trademarks of AURALiC in the Hong Kong and or other countries AURALiC s trademarks may not be used in connection with any product or service that is not AURALiC s in any manner that is likely to cause confusion...

Страница 3: ...gh speed switching components was deployed in output stage to maximize the driving capability and reduce heat dissipation With Hybrid Analog Amplify technology MERAK owns excellent linearity great output power as well as high energy efficiency Purer Power Linear Power Solution To satisfy this AURALiC tailor made Purer Power Linear Power Solution for a pure and abundant power supply The 500VA main ...

Страница 4: ... Indicator 10 Over Temperature Protection 10 Yellow Flash Error 10 Automatic Mode Control 11 Burn in period and Warm up 11 Maintenance Service 12 Maintenance 12 Service 12 Contact 12 Troubleshooting 13 No Power 13 No Sound or Low Output 13 Distorted or Partial Sound 13 Noise Hum 13 Specifications 14 EC Declaration of Conformity 15 AURALiC Product Registration Form 17 ...

Страница 5: ...acle Do not use the product near water i e near a bathtub kitchen sink laundry tub in a wet basement near a swimming pool etc Do not install the product near heat sources such as radiators heat registers stoves or other apparatus that produce heat See Placement and Cabling on page 7 Do not let objects or liquids fall into the product Do not expose the product to dripping or splashing Do not place ...

Страница 6: ...y AURALiC or by an authorized AURALiC repair agency Work done by unauthorized persons will void any and all warranty coverage AURALiC products are uniquely identified with a serial number S N on the back of the unit This number is required to validate your warranty Please reference your serial number if service is required Before the product can be returned for service an RMA Return Material Autho...

Страница 7: ...t peak output It should be installed in a space with at least five inches of clearance behind two inches both sides of its enclosure to provide adequate ventilation Avoid placing it directly above other equipment that produces heat Check Your AC Mains Voltage MERAK is shipped with its mains voltage preset for operation in the destination country The mains voltage setting is written on the back of ...

Страница 8: ...nect heavy gauge power cord from wall power supply to this socket please double check the AC mains voltage on the back of the panel before connecting the power Balanced Analog Input Analog input using XLR balanced connector with PIN2 as positive The input sensitivity of MERAK is set at 2 0Vrms with impedance at 10Kohm For single ended input a proper adapter is required with its PIN3 connect to GND...

Страница 9: ...ONTACT Operation The front panel of MERAK is shown as following 1 LED Indicator 2 Control Switch Power On Off MERAK will start up when the power switch on the back is toggled to I position and will turn off when the power switch is at O position For better balance between performance and energy saving MERAK is equipped with AURALiC s advanced power management circuit MERAK will automatically run a...

Страница 10: ...rotection Lighten in yellow Clip detected Flash in yellow Error Over Temperature Protection When internal temperature of MERAK exceeds 85 centigrade 185 Fahrenheit unit will shut down automatically for safety consideration It will go back to operation when tem perature is down to 60 centigrade 140 Fahrenheit If you encounter this problem please read the ventilation requirement on page 7 Yellow Fla...

Страница 11: ...de by manual the mode control is tempo rarily disabled and will not enable again unless the music signal on the input disap pear for a continuous 5 minutes The automatic mode control function is enabled by default to maximum the energy saving but can be set by user DISABLE when unit is wake up press the control switch on the front panel and hold for 3 seconds as long as you see the LED start to fl...

Страница 12: ...t your dealer or AURALiC Do not void the warranty by allowing unauthorized personnel to attempt repairs Do not attempt to service the product yourself Opening the cover may expose you to dangerous voltage as well as void the warranty Before MERAK can be returned for service an RMA Return Material Authorization number must be issued by AURALiC Contact your dealer or AURALiC for further infor mation...

Страница 13: ... is producing an audible input signal Distorted or Partial Sound Check the cables between the MERAK and associated components making sure all connections are good and sound Check out the output level of your source component and make sure it will not over drive MERAK s input Noise Hum Check the input cables between MERAK and associated components making sure all connections are good and sound Make...

Страница 14: ...Input Port 1 x XLR Sensitivity 2 2Vrms RCA input requires adapter Input Impedance 10K ohm Output Ports 1 x XLR invert output for BTL mode 1 x Cardas patented CE binding post Damping Factors 800 8ohm 1Khz Optimized Loads 2 ohm to 16 ohm Power dissipation warm up mode 5W playback mode 15W 450W idle max output Dimension 11 W x 11 D x 2 75 H 33cm x 33cm x 7 0cm Weight 19 lbs 8 5kg All specifications a...

Страница 15: ...formity of the designated product with the provisions of Directive number 73 23 EEC LVD is proved by full compliance with the following standards EN60065 2002 General requirements The conformity of the designated product with the provisions of Directive number 89 336 EEC EMC is proved by full compliance with the following standards EN55013 2001 Conducted emissions EN55013 2001 Absorbed emissions E...