58
| Controlling the Display Remotely
Control Functions - Get Command List
OSD
mode
Get Function Len
ID Cmd
Type
Cmd
Code
(Hex)
Value Range (ASCII Bytes)
Wait
response
time (ms)
Remark
All
Power 8
g
56
000:
Standby
150
001: On
Volume
8
g
51
000 ~ 100
100
Mute
8
g
52
000: Off
100
001: On
Signal Status
8
g
32
000: Signal unstable (or no
signal)
100
001: Signal stable (Active Sync
exists)
5V
10
g
57
04750~05250, tolerance is
-5%~+5%
100
value=4846 means
4..846V
12V
10
g
58
11400~12600, tolerance is
-5%~+5%
100
value=11707 means
11.707V
Operation Time
10
g
5F
00000 ~ 99999 (Operation time
when normal power off process
is executed)
100
unit is minute
Cumulative
working time
10
g
88
00000 ~ 99999
100
unit is minute
Thermal
Sensor Value
10
g
5A
(1) Input value: Byte1-Byte2-
...Byte5
(a) Byte1=
0x01: Get the thermal
sensor value from main
board
0x02: Get the thermal
sensor value from keypad
board
(b) Byte2~Byte5 are
reserved, should b 0x00
(2) Return value: Byte1-Byte2-
...Byte5
(a) Byte1=0x01: The thermal
sensor value is from main
board
(b) Byte2:
If the thermal value is
>=0, Byte2='+' (0x2B)
If the thermal value is <0,
Byte2='-' (0x2D)
(c) Byte3~Byte5: The
absolute value of the
temperature, in ASCII
format.
100
Ex: If the
temperature 5°C is
from main board,
the return value
should be:
Byte1=0x01,
Byte2=0x2B,
Byte3=0x30,
Byte4=0x30,
Byte5=0x35.