8.2
Setting of end stop OPEN
The swing angle has been set in the factory to approx. 90° or to the swing
angle stated in the order. An adjustment might be necessary if the end stop
CLOSED has been re-adjusted.
.
Check whether mechanical end position of the valve corresponds to the
mechanical end stop of actuator by turning at handwheel
(counter-clockwise for end position OPEN)
.
If necessary, remove screw plug (22.2, figure B2) and adjust mechanical
end stop at hex. socket head cap screw (21.2, figure B2).
.
Check O-ring in screw plug and replace if damaged.
.
Replace and fasten screw plug (22.2).
8.3
Setting values for mechanical end stops
10
Part-turn actuators SG 03.3 – SG 04.3
with AUMATIC AC 01.1
Operation instructions
T
T
m in .
T
min.
T
Fig. B4: (top view)
Fig. B5: (top view)
MOV
M
Fig. B2: Setting end position OPEN
Fig. B3: Setting end position CLOSED
(top view)
(top view)
21.2
22.2
22.1
21.1