![AUMA SARVEx 07.2 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/auma/sarvex-07-2/sarvex-07-2_operation-instructions-manual_3016487055.webp)
Figure 60: Torque
Select unit
The push button allows to select the unit displayed (in percent
%
, in Newton metre
Nm
or in pounds per foot
ft-lb
.
Figure 61: Units of torque
Display in percent
100 % indication equals the max. torque indicated on the name plate of the actuator.
Example: SA 07.6 with 20 – 60 Nm.
●
100 % corresponds to 60 Nm of nominal torque.
●
50 % corresponds to 30 Nm of nominal torque.
Multiport valve positions (S0017)
For activated multiport valve function, the display
S0017
above the position setpoint
E2 indicates a second bar chart showing the selection positions (valve connections).
Positions (P1, P2, ...) are indicated by a black triangle: . Positions can be selected
using the push buttons
. Both the positions as well as the current position setpoint
E2 are displayed in degrees.
Figure 62: Status indication for multiport valve (example P4 = 180°)
P
(P1, P2, ...) selected position (1, 2, ...)
(– –) no position selected
E2
Actual position value
8.2.2.
Status indications according to AUMA classification
These indications are available if parameter
Diagnostic classific. M0539
is set to
AUMA
.
Warnings (S0005)
If a warning has occurred, the display shows
S0005
:
●
the number of warnings occurred
●
a blinking question mark after approx. 3 seconds
55
SAVEx 07.2 – SAVEx16.2/SARVEx 07.2 – SARVEx16.2 Control unit: electronic (MWG)
ACVExC 01.2 Non-Intrusive
Indications