background image

Note:

Please state type and commission no. of the actuator (see name plate) when ordering spare parts. Delivered spare
parts may slightly vary from the representation in these instructions.

31

Multi-turn actuators SAI 6 – SAI 100 / SARI 6 – SARI 100

Operation instructions

for valve automation Inside Containment in nuclear power plants

Nr.

Designation

1

Housing

2

Cover

3

External bearing retainer

4

Internal bearing retainer

5

Declutch lever

6

Clutch roller pin, short

7

Clutch roller pin, long

8

Clutch fork assembly

9

Declutch latch

10

Extension spring

12

Clutch ring support pin

13

Spring tension plate

14

Declutch tripping arm

15

Retaining plate

16

Return spring

17

Washer

18

Bushing

19

Snap ring

21

Worm shaft assembly

23

Bearing flange

24

Hollow shaft

25

Compression spring

26

Clutch ring

27

Helical gear
(SAI / SARI 6 only)

30

Handwheel retainer

35

Helical pinion

36

Pinion with shaft

37

Compression spring

01

O-ring (clutch roller pin)

02

O-ring (declutch lever)

03

O-ring (drive assly. flanges)

04

O-ring (bearing retainer)

06

O-ring (bearing flange)

07

O-ring (cover)

013

Oil seal

014

Oil seal (subclause 15.4).

017

Ball bearing

021

Circlip

022

Circlip

023

Circlip

024

Circlip

025

Circlip

027

Circlip

030

Hexagon bolt

No.

Designation

031

Hexagon bolt

032

Reduced-shaft bolt

033

Oval head screw

034

Hexagon bolt

035

Socket head cap screw

038

Cotter pin

039

Parallel key

041

Blinker switch

043

Clamping washer

045

Lock washer

047

Lock washer

048

Socket head cap screw

052

Support washer

056

Roll pin

058

Star washer

2.1

Pinion

2.2

Spur gear

2.3

Motor mounting flange

2.4

Shield

2.6

Worm wheel

2.7

Motor

2.8

Gasket

2.02

Gasket

2.05

Hexagon bolt

2.06

Lock washer

2.09

Washer

2.010

Hexagon bolt

2.011

Lock washer

2.012

Socket head cap screw

2.013

Lock washer

3.1

Indicator assembly

3.5

Indicator glass

3.6

Glass retaining ring

3.01

O-ring (indicator glass)

3.02

Socket head cap screw

3.03

Lock washer

4.7

Shaft coupling (type D)

4.8

Mounting flange (D+E)

4.11

Mounting flange (A)

4.12

Stem nut (type A)

4.13

Bearing lock nut

4.21

Mounting flange (B+C)

4.22

Dog coupling
(type C)

No.

Designation

4.23

Thrust ring

4.24

Plug sleeve (type B)

4.75

Drive socket (type E)

4.05

Stud bolt

4.06

Washer

4.07

Hexagon nut

4.09

Hexagon bolt

4.010

Lock washer

4.011

Parallel key

4.012

Lock washer

44.01

Grub screw

44.02

Grease nipple

44.03

Needle bearing

44.04

Bearing race

7.1

Microswitch (limit)

7.2

Microswitch (torque)

7.05

Socket head cap screw

7.06

Lock washer

9.1

Potentiometer

9.01

Socket head cap screw

9.02

Lock washer

Содержание SAI 100

Страница 1: ...Electric multi turn actuators Operation instructions for valve automation Inside Containment in nuclear power plants SAI 6 SAI 100 SARI 6 SARI 100...

Страница 2: ...tting the limit switching 14 9 1 Setting end position CLOSED 14 9 2 Setting end position OPEN 14 10 Setting the DUO limit switching option 15 10 1 Setting direction CLOSE 15 10 2 Setting direction OPE...

Страница 3: ...g 28 21 Service and training 28 22 Spare parts list actuators SAI SARI 6 SAI SARI 100 30 22 1 Electrical connection with terminals 32 22 2 Electrical connection with AUMA plug socket connector 33 22 3...

Страница 4: ...Non observance of the warnings and notes may lead to serious injuries or damage Qualified personnel must be thoroughly familiar with all warnings and notes in these operation instructions Correct tra...

Страница 5: ...ndwheel reduction via bevel gearbox Electrical connection Standard Terminals Options AUMA plug socket connector Line bushings qualified for DBE conditions lengthwise lead seals Threads for cable gland...

Страница 6: ...peration instructions Other information EU Directives Electromagnetic Compatibility EMC 2004 108 EC Low Voltage Directive 2006 95 EC Machinery Directive 2006 42 EC Reference documents Product descript...

Страница 7: ...ing consists of environmentally friendly materials which can easily be separated and recycled We use the following packaging materials wood cardboard paper and PE foil For the disposal of the packagin...

Страница 8: ...b screw 44 01 Completely unfasten bearing lock nut 4 13 with pin wrench Remove stem nut 4 12 together with the upper needle bearing 44 03 and the bearing races 44 04 Protect the removed needle bearing...

Страница 9: ...n Push down change over lever as indicated by the arrow figure C n a n man a operation ere tor e pre ent at t e o tp t r e e t t r e n e er t n e e en t r e s pp e t t e tp t r e e st t r e ter tr pp...

Страница 10: ...emove socket carrier 2 from plug cover 1 Insert cable glands suitable for connecting cables The enclosure protection stated on the name plate is only ensured if suit able cable glands are used Only ca...

Страница 11: ...ls Technical data Power terminals Protective earth Control terminals Terminals max 3 1 50 Description U1 V1 W1 1 to 50 Connecting voltage max 750 V 250 V Type of customer connection Screws Screws Scre...

Страница 12: ...of non acidic grease e g Vaseline to the sealing faces Replace terminal cover or plug cover and fasten bolts evenly crosswise Fasten cable glands with the specified torque to ensure the required enclo...

Страница 13: ...supervision of such an electrician and in accordance with the applicable electrical engineering rules 8 1 Removing the cover from the switch compartment Remove bolts and take off the cover at the swi...

Страница 14: ...handwheel counterclockwise until valve is open then turn back by approximately a turn Push the stud figure J 1 inwards using a screwdriver and turn it The stud remains in this position Slowly turn se...

Страница 15: ...into its original position by spring action LSC Limit switch clockwise closing LSO Limit switch counterclockwise closing LSA Limit switch DUO clockwise rotation LSB Limit switch DUO counterclockwise r...

Страница 16: ...s on the dial indicate the values in mkp 1 mkp 10 Nm 1 lbsft 1 36 Nm Example Setting in figure S 12 mkp 120 Nm Tighten lock screw O again The torque switches can also be operated in manual operation T...

Страница 17: ...urns counterclockwise the direction of rotation is correct If the direction of rotation is wrong switch off immediately Then correct phase sequence at the motor connection and repeat test run 12 2 Che...

Страница 18: ...amount of additional rotation of stem after actuator has been switched off Manually move valve in direction CLOSE figure L 5 while observing cam for limit switch LSC figure L 4 For limit seating in d...

Страница 19: ...require setting Close switch compartment see page 24 clause 16 19 Multi turn actuators SAI 6 SAI 100 SARI 6 SARI 100 Operation instructions for valve automation Inside Containment in nuclear power pl...

Страница 20: ...reduction gearings for the position transmitter the complete resistance range is not always utilized for the whole travel Therefore an external possi bility for adjustment setting potentiometer must b...

Страница 21: ...if necessary 21 Multi turn actuators SAI 6 SAI 100 SARI 6 SARI 100 Operation instructions for valve automation Inside Containment in nuclear power plants Terminal plan KSA _ _ _ Output current Ia 0 2...

Страница 22: ...urrent starts to increase Turn back potentiometer P1 until the following value has been reached for 3 or 4 wire system approx 0 1 mA for 2 wire system approx 4 1 mA This ensures that the signal does n...

Страница 23: ...Turn back potentiometer P1 until a residual current of approx 0 1 mA has been reached Move valve to end position OPEN Set potentiometer P2 to end value 16 mA Move valve to end position CLOSED Set pot...

Страница 24: ...ent with the mark on the cover Indicator disc rotates approximately 270 at full travel from OPEN to CLOSED or vice versa 16 Closing the switch compartment Clean sealing faces of housing and cover Chec...

Страница 25: ...g for tightness in the factory Cable glands For the entries of the motor and control cables appropriate cable glands in enclosure protection IP 68 must be used The size of the cable glands must be sui...

Страница 26: ...ommended that a visual inspection for grease leakage is performed on each actuator at least every 2 years Functional test Every 5 years the performance of each actuator should be tested in detail and...

Страница 27: ...t presse r Fill in new grease respecting correct quantity see table below Replace seals at handwheel Apply grease to lower part of handwheel hub Place handwheel with hub in housing thereby turning it...

Страница 28: ...stances are hazardous to water and must not be released into the environment See disassembled material to a sound disposal or to separate recycling according to materials Observe the national regulati...

Страница 29: ...Notes 29 Multi turn actuators SAI 6 SAI 100 SARI 6 SARI 100 Operation instructions for valve automation Inside Containment in nuclear power plants...

Страница 30: ...n Inside Containment in nuclear power plants Operation instructions Sample name plate Commission number Works number Actuator type Enclosure protection output speed Torque range in CLOSED OPEN Speed o...

Страница 31: ...23 Circlip 024 Circlip 025 Circlip 027 Circlip 030 Hexagon bolt No Designation 031 Hexagon bolt 032 Reduced shaft bolt 033 Oval head screw 034 Hexagon bolt 035 Socket head cap screw 038 Cotter pin 039...

Страница 32: ...017 5 020 5 023 5 025 5 026 5 3 5 03 5 018 5 021 5 024 5 025 5 026 5 01 5 1 5 02 5 2 No Designation 5 1 Terminal frame 5 2 Terminal box cover 5 3 Terminal rails 5 01 O ring 125 X 3 5 5 02 O ring 240 X...

Страница 33: ...valve automation Inside Containment in nuclear power plants No Designation 1 Cover 2 Socket carrier complete 3 Adapter plate 4 Pin carrier 5 Adapter plate 6 Cable harness for protective earth 01 Hexa...

Страница 34: ...nts Operation instructions 28 05 066 028 010 18 29 47 014 064 06 No Designation 18 Bushing 28 Handwheel hub 29 Handwheel 47 O ring retainer 05 O ring for handwheel hub 06 Parallel key No Designation 0...

Страница 35: ...plants No Designation 1 Mounting flange upper part 2 Mounting flange bottom part 3 Hollow shaft 4 Stem nut 5 Bearing lock nut spring loaded in both directions 6 Thrust ring 7 Collar spring loaded in...

Страница 36: ...pare parts list seal kit for actuators SAI SARI 6 SAI SARI 100 36 Multi turn actuators SAI 6 SAI 100 SARI 6 SARI 100 for valve automation Inside Containment in nuclear power plants Operation instructi...

Страница 37: ...g __ 050 52 x 1 78 K000 399 1 069 45 x 3 53 K000 403 1 088 50 x 3 53 K000 407 1 014 Radial seal BABSL 35 x 52 x 6 D000 222 1 __ __ __ __ __ __ 064 1 O ring 56 82 x 2 62 D001 640 1 76 x 2 D000 361 1 10...

Страница 38: ...Declaration of Incorporation and EC Declaration of Conformity 38 Multi turn actuators SAI 6 SAI 100 SARI 6 SARI 100 for valve automation Inside Containment in nuclear power plants Operation instructio...

Страница 39: ...Lubrication 27 M Maintenance 4 Manual operation 9 Mechanical position indicator 24 Motor protection 11 Mounting to valve gearbox 7 N Name plate 30 O Output drive type AF 9 35 Output drive types 7 Ove...

Страница 40: ...ed information about AUMA products refer to the Internet www auma com Y000 580 003 en 2 AUMA Riester GmbH Co KG P O Box 1362 DE 79373 Muellheim Tel 49 7631 809 0 Fax 49 7631 809 1250 info auma com www...

Отзывы: