Check actuator.
●
In case of ingress of water, locate leaks and repair. Dry device correctly and
check for proper function.
13.2.
Disconnection from the mains
If the device must be dismantled, e.g. for service purposes, it can be isolated from
the mains without having to remove the wiring at the electrical connection.
Figure 76: KL electrical connection
[1]
Cover
[2]
Screws for cover
[3]
O-ring
[4]
Screws (with gaskets) within connection frame
[5]
Connection frame
[6]
Grub screws within connection frame
Ignition of potentially explosive atmospheres caused by sparks!
Risk of death or serious injury!
→
Before opening the flameproof enclosure, ensure absence of gas and voltage.
→
Handle cover and housing parts with care.
→
Flameproof joints must neither be damaged nor soiled in any way.
→
Do not jam cover during fitting.
Removing the plug:
1.
Loosen the screws [2].
2.
Remove cover [1].
3.
Remove grub screws [6] inside the connection frame.
4.
Loosen screws [4] inside the connection frame.
5.
Remove electrical connection.
Fitting the plug/socket
connector:
6.
Clean sealing faces of plug/socket connector, cover and housing.
7.
Preserve joint surfaces with an acid-free corrosion protection agent.
8.
Check whether O-rings [3] are in good condition, replace if damaged.
9.
Apply a thin film of non-acidic grease (e.g. petroleum jelly) to the O-rings and
insert them correctly.
10. Fit electrical connection (connection frame) and fasten screws [4] (with gaskets)
evenly crosswise.
11. Fasten grub screws [6] (tightening torque approx. 10 Nm).
Information: The flameproof enclosure is only guaranteed provided the grub
screws are fastened [6].
81
SAEx 07.2 – SAEx 16.2/SAREx 07.2 – SAREx 16.2 Control unit - electromechanical
ACExC 01.2 Intrusive Profinet
Servicing and maintenance