86
COMpact 5000/R - Firmware V6.6A - Installation, Operation and Configuration V05 03/2016
Installation and Commissioning
Analogue End Devices
Installing Cables and Wall Sockets at the Internal a/b Port
Further steps:
•
To finish commissioning, you need to set up an internal number for the end device in the
configuration manager.
Installing Cables and Wall Sockets at the Internal a/b Port
Requirements:
•
Cover panel is removed
•
Inserted COMpact 4FXS module
•
Maximum distance/line length between the devices depending on the cable used (with a
pair diameter of 0.6 mm: approximately 800 m )
•
Per a/b port, one wire pair of an installation cable (e. g. J-Y(St)Y 2x2x0.6)
•
Under unfavourable conditions, for example, near a strong transmitter or an electrical
power line: screened cable
•
For telephones or combination fax/answering machines: a TAE wall socket with F coding (a
single socket labelled with an
F
)
•
For fax machines, modems, and call answering machines: a TAE wall socket with an
additional socket with N coding
1. Lay the line.
Warning:
Power surges, which can occur during electrical storms, can
cause life-threatening electric shocks or damage or destroy the PBX.
•
Hire a qualified electrician to lay the cables within the building.
•
Do not use the a/b ports to connect remote extensions.
Note:
For a structured cable installation configured on the COMpact
5000R, CAT 5 cables and CAT 5 wall sockets are used instead of the
cables and wall sockets listed here. To connect an analogue device, a
commercially-available RJ-45/TAE adapter is required.
Important:
For a structured cable installation on the COMpact 5000R, the
line length of all applicable end devices must be taken into account.