Contents 
 

Security Advice ..................................................................................................................................... 2 
Scope of Supply .................................................................................................................................... 2 
Overview ............................................................................................................................................... 3 
Open the housing .................................................................................................................................. 3 
Closing the housing............................................................................................................................... 6 
Labelling the name plates ..................................................................................................................... 8 
Programming......................................................................................................................................... 9 
Analog switch modules ....................................................................................................................... 12 
Connection diagrams .......................................................................................................................... 14 

Содержание a/b-Schaltmodul

Страница 1: ...short manual for operation installation mounting and programming Contents Security Advice 2 Scope of Supply 2 Overview 3 Open the housing 3 Closing the housing 6 Labelling the name plates 8 Programmin...

Страница 2: ...ive or solvent based detergents NOTE The device is weatherproof and does not need additional care When dirty please clean the device using a damp cloth Scope of supply Base unit TFS Dialog 200 201 204...

Страница 3: ...2 Press the key in the direction A against the force of the spring to the stop and hold it 3 Push the name plate 3 with slight force into direction B until it comes out of the profile 4 Pull the key...

Страница 4: ...he name plate is removed and can be labelled as described later 7 Release the illumination plate with the special key by pressing on the spring in direction F Please observe it is connected with a cab...

Страница 5: ...this device Please observe when choosing the mounting location that this device is not exposed to direct rainfall Do not mount this unit on free standing objects which are not protected against rainfa...

Страница 6: ...ntioned below Closing the housing Installation and mounting For the storage of reserve cabling a flush mount socket can be used optionally like indicated in the drawing above WARNING Fluids intruding...

Страница 7: ...8 Push the special key into its hole and press down the spring in direction Q 9 Put the lighting plate with its upper end first into the housing 10 Press down the lower end in a way that it is safely...

Страница 8: ...plates 1 Open the housing using the spezial key and take out the name plate glass 3 2 Label the name plates 17 directly with a pen or use the print templates you can find on www auerswald de under Ser...

Страница 9: ...ng code of the desired function Wait for the end of the acknowledgement tone Programming Wait for the end of the acknowledgement tone Dial the programming code of the desired function Wait for the end...

Страница 10: ...cy Only necessary once see above on the first page Allocation of additional door bells to the bell buttons 1 4 default 1 2 0 0 Setting of the switching time for lighting default 0 5 sec Only necessary...

Страница 11: ...ts possible 1 6 digits Will be activated from the phone by dialling digits Setting of the input sensitivity default 1 Setting the volume of the loudspeaker default 6 Seeting the environment sound leve...

Страница 12: ...rtain numbers Please observe the a b switching modules are not made for 230 V For this you would have to use a matching relay in between The switching lasts for 1 to 4 5 seconds if you need a longer t...

Страница 13: ...controlled by using the integrated DIL switch Switching frequency 1 Switching frequency 2 Switching frequency 3 Switching frequency 4 Switching frequency 5 Switching frequency 6 Four switching freque...

Страница 14: ...use a time relay like a staircase light controller For this case every a b switching module comes with an additional resistor which can be connected to the electronic door bell or a staircase light co...

Страница 15: ...itching module Additional resistor 330 capacity min 1 W Door opener Staircase light controller Control of door openers and staircase lighting with a b switching modules Control of additional bells doo...

Страница 16: ...3 Bell output 1 4 Bell output 2 5 Connection for the door opener 6 Connection for stairway lighting 7 Common connection for the Supply voltage out of the ringing transformer 1 7 2 Example basic connec...