INSTALLATION

 

PRIMO PILOT 

MANUAL

30

9 - WARRANTY

• The tank is guaranteed for a period

 

five (5) years 

against breakage,  

starting from the date of fi rst use if the warranty form was returned to the 
manufacturer, In the absence of this form, the date of manufacture will be 
used as a reference point for the start of warranty. 
• The spare parts (see attached list) are guaranteed for a period of 

two (2) 

years

 starting from the date of fi rst use if the warranty form was returned 

to the manufacturer, In the absence of this form, the date of manufacture 
will be used as a reference point for the start of warranty. 

The appliance is guaranteed against all manufacturing defects, provided
that it was installed according to the instructions provided in this manual
and in compliance with all current rules and regulations in the country of
installation. All electrical connections should comply with the C15-100
standard. 

Under no circumstances does a defective part warrant the replacement 
of the whole appliance. 

The warranty only applies to parts which we (AUER) identify as having 
been defective at manufacture. If necessary, the part or product should 
be returned to the manufacturer, but only with prior agreement from 
our technical department. Labour, transport, and packaging costs 
are the responsibility of the user. Repairs on a device will not result in 
compensation. 

The warranty on replacement parts ends at the same time as the warranty 
of the appliance. 

The warranty only applies to the appliance and its components and 
excludes any part or installation external to the appliance: electrical parts, 
hydraulic components, etc...

The warranty will not apply in the absence of, insuffi

  cient, or improper, 

maintenance of the appliance.

It is essential to carry out regular annual maintenance on the 
appliances and on the installation to ensure sustained use and 
durability. This maintenance should be carried out by your 
installer, or by an AUER-approved technical center. In the absence 
of regular maintenance the warranty is rendered null and void.

If an appliance is presumed to be the cause of any damage, it must not be 
moved or tampered with before an expert assessment has been carried out. 

9.1 - Warranty coverage

9.2 - Limitations of warranty

9.2.1 - General information

The warranty does not apply to defects or damage caused by situations 
or events such as: 

• Misuse, abuse, negligence, improper transport or handling.
• Incorrect installation, or installation which has been carried out without 

following the instructions in the manual and user guide.

• Insuffi

  cient maintenance.

• Modifi cations or changes carried out on the appliance.
• Impacts from foreign objects, fi re, earthquakes, fl oods, lightning, ice, 

hailstones, hurricanes or any other natural disaster. 

• Movement, imbalance, collapse or settling of the ground or the 

structure where the appliance is installed.

• Any other damage which is not due to defects in the product.

The 

PRIMO

 

Pilot

 

is not guaranteed against:

•  Variations in the colour of the appliance or damage caused by air pollution, 

exposure to chemical elements, or changes brought about by adverse 
weather conditions

• Dirt, rust, grease or stains which occur on the surface of the appliance.

9.2.2 - Cases (not limited to) for exclusion from 

warranty

9.2.2.1 - Usages

Cases (not limited) for exclusion from warranty:

• Filling with anything other than domestic cold wate from the drinking 

water network; such as rain-water, well-water, ...etc, or using domestic 
cold water which is particularly aggressive and not in compliance 
with the national regulations in eff ect in the country of use (DTU 60-1 
addendum 4 concerning hot water).

• Switching on the appliance without fi rst having fi lled it with water.

9.2.2.2 - Handling

Cases (not limited) for exclusion from warranty:

 • Any damage sustained by impacts or falls during handling after  

delivery from the factory.

  • Deterioration in the condition of the appliance after handling where 

the instructions in the manual have not been followed. 

9.2.2.3 - Installation site

Cases (not limited) for exclusion from warranty:

• Placement of the

 

PRIMO

 

Pilot

 in a location where it could be subject 

to ice

  frost or other adverse weather conditions. 
• Not positioning the appliance in accordance with the instructions in 

the installer manual. 

• Installation of the appliance against a wall which cannot support the 

weight of the appliance when fi lled with water.

Costs incurred due to access difficulties are not the manufacturer’s 
responsibility. 

9.2.2.4 - Electrical connections

Cases (not limited) for exclusion from warranty:

  • Faulty electrical connection which does not conform to the national 

standards in eff ect. 

 • Not following the electrical connection diagrams provided in the 

installer manual. 

 • Electrical supply being signifi cantly over- or under- the required 

voltage. 

  • Not respecting the supply cable sections. 
 • Absence of, or insufficient electrical protection throughout the 

appliance (fuses / circuit breaker, grounding…).

• Damages caused after the neutralisation of the safety aquastat, or due 

to not having installed an appropriate safety aquastat for underfl oor 
heating. 

9.2.2.5 - Hydraulic connections

Cases (not limited) for exclusion from warranty:

  • Reversing the inlet/outlet connections. 
  • Water pressure over 7 bars.
 • Absence of, improper mounting of, or obstruction of pressure-relief 

valves. 

• Not installing pressure relief valves directly on the outlet for domestic 

cold water of the appliance. 

• Installing pressure relief valves which do not comply with the national 

regulations in eff ect (NF EN 1487 for France).

• Using pressure relief valves which are previously used. 
• Not respecting the plumbing of the pressure relief valves. 
• Abnormal corrosion due to improper hydraulic connections (direct 

contact between iron/copper) without a sleeve (cast iron, steel, or 
insulated). 

•  External corrosion due to piping being improperly sealed.

In no case can compensation be claimed due to damages caused by the 
absence of thermostatic mitigators. 

9.2.2.6 - Accessories

The warranty does not cover faults or defects resulting from:

• Installation of accessories which do not comply with our 

recommendations. 

• The use of accessories which do not come from the manufacturer of 

the appliance.

9.2.2.7 -  Maintenance

Cases (not limited) for exclusion from warranty:

• Not maintaining the appliance.
• Not maintaining the pressur relief valves leading to high pressures. 
• Abnormal levels of limescale on the heating elements and of the 

safety devices. 

•Not using parts issued by the manufacturer. 
•Outer casing and bodywork being subjected to any external damage. 

Содержание PRIMO pilot

Страница 1: ... pump Ref 753010 PRIMO pilot Pilot for HRC70 HTi70 heat pumps The information contained in this document is non contractual Auer reserves the right to modify the technical specifi cations or characteristics of any of their appliances without prior notice Concerns the HTI70 6 and 8 single phase models ...

Страница 2: ... 4 4 5 Underfloor safety device of the 65 C safety aquastat OPT with manual reset OPT 14 5 SET UP 15 5 1 Beforeset up 15 5 2 Check watertightness 15 5 3 Starting set up 15 5 4 Step 1 Circuit choice 15 5 5 Step 2 Filling 15 5 6 Step 3 Purging the installation 16 5 7 Step 4 Choosing the back up 16 5 8 Step 5 Finishing set up 16 5 9 1st use 16 6 SETTINGS AND FUNCTIONS 17 6 1 Control panel 17 6 1 1 Ke...

Страница 3: ...g points following the instructions for operating installing and maintaining this appliance and all of its components ensuring the compliance of the appliance to all inspection and maintenance conditions which are listed in this manual Danger of death by electrocution Touching live electrical wires can cause severe bodily injury and lead to death by electrocution All installation and maintenance w...

Страница 4: ...ust be respected in their current version in effect The electrical supply must conform to all applicable regulations in the country of installation as well as the NFC 15 100 standard Amethodofdisconnectionensuringacomplete cut off must be installed in the fixed piping to conform to installation regulations do not use a movable outlet Protect the appliance with a 2 pole circuit breaker with a minim...

Страница 5: ...intervention on the product before handling installation use and maintenance Maximum working pressure PSmax Heat power output produced Indicatesthemaximumwatertemperatureinoperation Admissible storage and transport temperatures are from 20 C to 60 C The PRIMO Pilot must be stored and transported on its pallet and in its original packaging and empty of water 2 5 Storage and transport 2 8 End of lif...

Страница 6: ... of a heating circuit and depending on the options selected the production of domestic hot water for the household The PRIMO Pilot is meant to be connected to an HRC70 or HTI70 range heat pump The PRIMO Pilot is delivered ready to use in its factory set configuration see Set up This configuration allows a simpified start up with factory set parameters and without access to certain settings However...

Страница 7: ...ement 3 Power terminal 4 Circulator pump 5 Electronic circuit board 6 Expansion vessel 7 Heat pump 8 Decoupling pump optional 9 By pass optional 10 Heating circuit radiator or underfloor heating 11 Domestic hot water circuit 12 Decoupling kit 3 5 Operating principles ...

Страница 8: ...te product This allows to eliminate all traces of soldering waste joint filler grease sludge metallic particles etc in the radiators underfloor heating etc 4 2 1 4 Preparing the hydraulic circuit rinsing A sufficient flow rate should be ensured so that the difference in temperature between the outlet and inlet points does not exceed 6 C Inaninstallationequippedwiththermostaticmixingvalves this ins...

Страница 9: ...datory to install a 65 C safety aquastat OPT with manual reset OPT on the underfloor heating outlet CAUTION WHEN THE INSTALLATION INCLUDES A SANITARY TANK 4 2 1 7 Underfloor heating It is IMPERATIVE to refer to the installation instructions for the initial installation of the ambient temperature thermostat to ensure satisfactory operation In an installation with both thermostatic valves and a room...

Страница 10: ... on the PRIMO Pilot would be 0 5 bars less than the real pressure of the water in the Heat Pump In this case the maximum service pressure for the PRIMO Pilot would be 2 bars Therefore it would be advisable to fill the heating circuit at an intermediary pressure between 1 and 1 5 bars For safety reasons potential presence of flammable R290 gas drainage of the Pilot s pressure relief valve must MAND...

Страница 11: ...MANUAL 11 4 2 2 Hydraulic connections Description Hydraulic connections 1 Outlet towards DHW Heating 3 4 2 Inlet from HP 3 4 3 Outlet towards HP 3 4 4 Inlet from DHW circuit 3 4 5 Inlet from Heating circuit 3 4 6 Draining valve ...

Страница 12: ...ded connections of the pilot the pipe with a nut on both sides must be connected to the return of the heating circuit First do not tighten the nuts Electrical connection of the decoupling kit Installonlythedecouplingkit Ref 753103 Sealsprovidedinthedecouplingkitmustbe correctlyplacedtoensurethetightnessof theinstallation Powersupplymustbedisconnectedbefore electricalconnectionofthedecouplingkit Th...

Страница 13: ... 10m length supplied The chosen back up on the terminal and the contactor Under no circumstances will the manufacturer be held liable for any problems which may arise due to improper installation and or choice of power supply cable The rules and regulations in the country of installation MUST be respected standard C15 100 The electrical lines for general power supply to thecircuitsmustbemadeincomp...

Страница 14: ...ad of the domestic hot water tank In an installation with both thermostatic valves and a room temperature thermostat the radiator s in the room in which the thermostatislocatedMUSTbeequippedwithamanualairvalve s It is mandatory to install the ambient temperature control on an interior wall of the room for control by the appliance and not a wall that lets out onto the outside of the building Instal...

Страница 15: ...gtheset up Forroomthermostats make suretheyareinheatingdemand sendinga closedcontacttothepilot NOTE Ifyouchoosenottostartset up NO thisoptionremainsaccessible in the expert menu by the COMMISSIO sub menu Inspecttheentiretyofthehydraulicconnections nutswithwashers toric joints or anything assembled with glue which may loosen during transport or during the installation process and tighten if necessa...

Страница 16: ... Step 3 Purging the installation During the cycle check that the automatic purgers are open and regularly activate the manual purgers If the pressure in the circuit becomes insufficient due to the volume of air purged the PRIMO Pilot will indicate it and will pause the purging cycle Activate the backflow prevention device or the filling valve to raise thepressure Thepurgingcyclewillresumeautomatic...

Страница 17: ...menu access return cancel locking unlocking of the keypad on off standby mode setting the temperatures program scheduled comfort modes increase the setting scroll up activate temporary comfort mode confirm remove error display pressure or T information on temperatures and current operating state decrese the setting scroll down activation of holiday mode defrosting in progress circulator pump worki...

Страница 18: ..._BACT Setting the speed of HP circulating pump Setting the speed of heating circulating pump Outside temperature on the warmest day Outside temperature on the coldest day Choice of back up Setting the heat curve 1 Heat curve 1 setpoint on the coldest day Heat curve 1 setpoint on the warmest day Activation of priority sharing Activation of anti bacteria function menu expert settings display data ca...

Страница 19: ...09 Maximum exterior temperature for operation using only the back up TEAPP The heat pump is authorised to operate in warmer temperatures C 20 to 10 20 P210 Full hour operation 0 no operation allowed 1 HP limited to 1st power stage 2 HP limited to 2nd power stage 3 full HP without back up 4 do not use 5 do not use 6 full autorization HP back up 7 back up without HP 8 anti frost confort level 9 eco ...

Страница 20: ...mbient temperature sensor difference in ambient temperature to engage a heating request K 0 1 to 1 0 5 P270 Temperature of primary circuit for cylinder controlled by aquastat dry contact C 20 to 70 60 P271 Domestic sharing simultaneous operation of heating and domestic hot water production at the end of the tank s heating cycle Increases the available heating time for installations with a larger v...

Страница 21: ...ontinuallycorrecttheheat curve to correspond to the needs of the household Auto adaptability operates on two modes which can be independently activated primaryauto adaptability activatedbyP238 examinestheheating needs over 24h cycles and adjusts the set temperature for heating when ambient temperature is requested complementary auto adaptability activated by P239 examines the heating needs over 3h...

Страница 22: ...en there is an ambient temperature request Control activated through parameter P234 6 5 3 3 Heating circulator control 6 5 3 4 Anti cold radiators This function is only possible with an ambient temperature sensor Circulationisalwayscontrolledbytheambienttemperaturecontrol When the set ambient temperature is reached the PRIMO Pilot adopts a lower set water temperature but continues to circulate so ...

Страница 23: ...mpressors version Heat pump version number T_COND Temperature of condenser sensor COMP1 Compressor 1 working state COMP2 Compressor 2 working state 7 2 2 Consulting the current operating state of the system 7 2 Diagnostics 7 2 1 Loading the operating history Theoperatinghistoryissavedinthememoryoftheelectronicboard This data can be loaded onto the USB stick provided The USB port is located on the ...

Страница 24: ...it C 25 Defrosting cycles quantity C 26 Frequent defrosting errors quantity C 27 Activation of high pressure switch for compressor n 1 quantity C 28 Activation of high pressure switch for compressor n 2 quantity C 29 Activation of low pressure switch for refrigerant fluid quantity C 30 Activation of high temperature for compressor n 1 exhaust quantity C 31 Activation of high temperature for compre...

Страница 25: ...omplete stop automatic after repair amb bus Amb BUS error The ambient temperature sensor Amb terminals on the pilot is defective or not connected properly heating circuit stopped automatic after repair cond senso diag Condenser fluid pressure sensor error The refrigerant circuit pressure sensor is defective or not connected properly operation in downgraded mode automatic after repair evap senso Ev...

Страница 26: ...ger Maintenance is needed on the hot water exchanger Hot water exchanger is clogged The tank s water sensor is misplaced check its position into the water tank thermowell informative message manual off peak Off peak hours signal Off peak hours signal is inactive There is a problem with the connection of the off peak hours signal operation in peak time hours manual cloc k Clock Proceed again to the...

Страница 27: ...cold temperature Check the heating circuits watertightness and repair the possible water leaks Bleed the air from the upper parts of the pilot Check that the heat pump safety valve is not leaking Check that the pilot safety valve is not leaking Ensure that expansion vessel is large enough for the installation s mater capacity complete stop automatic after pressure is returned cp1 ramp Temperature ...

Страница 28: ...w the heat exchanger or near the cold water inlet DHW circuit stopped manual cp1 senso T1 defect Defect of incorrect connection of the temperature sensor for the compressor or compressor n 1 depending on the model connector TCP1 on the HP heat pump stopped automatic after repair cp2 senso T2 defect Defect of incorrect connection of the temperature sensor for compressor n 2 TCP2 heat pump stopped a...

Страница 29: ... 20 B4994836 Preassembled control circuit board 21 B1244620 3 kW Heating element 22 B1244777 Power board 23 B1239089 Purger Non visible B1243561 Contactor 24 B1238802 Aquastat 25 B1244888 Control terminal 8 2 Hydraulic block 8 1 PRIMO Pilot 8 SPARE PARTS 0 1 1 2 2 3 Note Availability of spare parts The spare parts of our products are kept available for 10 years from the date of stop of mass produc...

Страница 30: ... appliance 9 2 2 Cases not limited to for exclusion from warranty 9 2 2 1 Usages Cases not limited for exclusion from warranty Filling with anything other than domestic cold wate from the drinking water network such as rain water well water etc or using domestic cold water which is particularly aggressive and not in compliance with the national regulations in effect in the country of use DTU 60 1 ...

Страница 31: ... included Expansion vessel 8 L Maximum hydraulic pressure 2 5 bar 1 filter valve delivered with connection kit included A1 2 Dimensions 790 A1 3 UE declaration This device complies with CEI 60335 1 CEI 60335 2 40 electrical securities international norms CE marking on the device attests its conformitytothefollowingCommunalGuidelines whichheanswers to essential requirements Low Voltage guideline BT...

Страница 32: ... and the heat pump A2 2 Minimum flow rate to respect depending on the heat pump model Distances for connection to HTi70 6 8 11 and 14 kW Minimum Ø of piping to respect HTi70 6kW and HTi70 8kW HTi70 11kW HTi70 14 kW 10m 22 24 24 26 28 30 10m and 15m 24 26 28 30 32 34 15m and 25m 28 30 32 34 36 38 25m and 50m 32 34 36 38 42 44 Heat pump model HTi70 6kW HTi70 8kW HTi70 11kW HTi70 14kW Minimum nominal...

Страница 33: ... INSTALLATION PRIMO PILOT MANUAL 33 A3 Wiring diagram ...

Страница 34: ...menu access return cancel locking unlocking of the keypad on off standby mode setting the temperatures program scheduled comfort modes increase the setting scroll up activate temporary comfort mode confirm remove error display pressure or T information on temperatures and current operating state decrese the setting scroll down activation of holiday mode defrosting in progress circulator pump worki...

Страница 35: ...I_BACT Setting the speed of HP circulating pump Setting the speed of heating circulating pump Outside temperature on the warmest day Outside temperature on the coldest day Choice of back up Setting the heat curve 1 Heat curve 1 setpoint on the coldest day Heat curve 1 setpoint on the warmest day Activation of priority sharing Activation of anti bacteria function menu expert settings display data c...

Страница 36: ...ue de la République CS 40029 80210 Feuquières en Vimeu Spare parts department Tel 03 22 61 21 21 Fax 03 22 61 33 35 E mail pieces auer fr Technical assistance department E mail enr auer fr Technical assistance is reserved for professionalss ...

Отзывы: