8 / 16
Programming
The Intercom Station IntellyCom 3T is designed to be programmed remotely over the
telephone line. Programming is carried out using sequences keyed from a telephone,
when connected to the IntellyCom 3T to be programmed.
Remote programming codes are split into two classes Class 0 and Class 1 which are
distinguished by different enclosing characters; “#” for Class 0 and “*” for Class 1.
The IntellyCom 3T accepts Class 1 programming codes only if the user has the right
to program. This is achieved by sending the Class 0 programming code
#AccessCode#. The factory setting is AccessCode=1234.
Class 0 programming codes are always accepted.
Programming Codes
For each programming sequence below the telephone responds with an acknowledge
or an error tone. In case of an error tone the programming sequence has to be
repeated.
Class 0 Programming Codes
Code
Function
#
accesscode
#
Request the programming rights
Factory setting:
accesscode=1234
The corresponding programming function refuses the values 0600 and 0990 and
responds with an error tone.
#
relaycode
#
Activate relay
Factory setting:
relaycode=1
The corresponding programming function refuses the values 0600 and 0990 and
responds with an error tone.
#0600#
Request phone_ID
#0990#
Cleardown
##
Deactivate relay
Class 1 Programming Codes
Code
Function
*100
dialmode
*
Select dial mode
dialmode=1
Tone dialing (DTMF)
dialmode=2
Pulse dialing 1.5:1
dialmode=3
Pulse dialing 2:1
Factory setting:
dialmode=1
Tone dialing (DTMF)